QSFP112 vs QSFP-DD vs OSFP-RHS: Choosing the Right 400G Form Factor for Switches and NICs
Share
Why the form factor matters as much as the optic
Most 400G buying starts with the optical question: SR4, DR4 or FR4, and multimode or single-mode. That choice sets reach and cabling. But a module also has to match the host port: its cage, its electrical lanes and how it is cooled. At 400G there are three common answers: QSFP-DD, QSFP112 and OSFP-RHS. Two 400G DR4 modules in different form factors may link to each other over fiber and still not fit the same port.
The three 400G form factors at a glance
| QSFP-DD (400G) | QSFP112 | OSFP-RHS | |
|---|---|---|---|
| Host electrical interface | 8 × 50G PAM4 | 4 × 100G PAM4 | 4 × 100G PAM4 (400G variants) |
| Mechanical footprint | Double-density QSFP (extra row of contacts) | Standard QSFP footprint | OSFP width, flat top |
| Thermal design | Cooled by the host cage and airflow | Cooled by the host cage and airflow | "Riding heat sink" sits on the host cage, not the module |
| Where you typically see it | 400G switch ports in spine-leaf fabrics | 100G-per-lane NICs and newer switch ports | OSFP-based server NICs and adapters |
QSFP-DD: the established 400G switch port
QSFP-DD adds a second row of electrical contacts to the familiar QSFP shape. That gives the port eight electrical lanes, and at 400G each lane runs 50G PAM4. That matches the 50G SerDes on the first generation of 400G switch silicon, so QSFP-DD became the common 400G port on data-center switches from vendors such as Cisco, Arista, Juniper and Dell.
Because the host side runs 8 × 50G and many current optics run 4 × 100G on the fiber, a 400G QSFP-DD DR4 or SR4 module includes a DSP that converts between the two. Many QSFP-DD ports also accept lower-speed QSFP modules, which helps during a phased migration. Check the switch's own documentation for which speeds each port supports.
QSFP112: 400G in the classic QSFP shape
QSFP112 keeps the standard four-lane QSFP footprint and runs each lane at 100G PAM4. The result is 400G with no lane conversion between the host and the optics. It appears on hosts built around 100G-per-lane SerDes. Some NVIDIA ConnectX-7 adapter variants are a common example, and so are newer switch platforms.
The trap: a QSFP112 module and a 400G QSFP-DD module are not interchangeable. The QSFP-DD module needs the double-density cage. The QSFP112 module expects 100G electrical lanes that a 50G-lane QSFP-DD host does not provide. Order by the host's port type, not by "400G" alone. A 400G example in this form factor is the 400G QSFP112 DR4.
OSFP-RHS: OSFP for NICs and space-constrained hosts
OSFP was designed with more room for power and heat than QSFP-type modules. The standard switch version has a finned top that carries its own heat sink. OSFP-RHS ("riding heat sink") has a flat top: the heat sink is part of the host cage and presses on the module. That suits PCIe adapters and other hosts where a finned module would not fit. The OSFP versions of NVIDIA ConnectX-7 adapters are a typical place you'll see it.
Finned-top OSFP and OSFP-RHS share a name but are not interchangeable in practice, because they are built for different cage and heat-sink designs. If the host documentation says "flat top" or "RHS", order RHS. A 400G example in this form factor is the 400G OSFP-RHS DR4.
Same optics, different shells: what still interoperates
Form factor is about the host port. The optical interface is set by the IEEE standard. A 400GBASE-DR4 link (IEEE 802.3bs, 4 × 100G PAM4 at 1310 nm over MPO-12 single-mode) can run between a QSFP-DD DR4 on a switch and a QSFP112 DR4 or OSFP-RHS DR4 on a server NIC, as long as both ends follow the same optical spec. In practice this is how many AI and HPC fabrics are built: QSFP-DD or OSFP on the switch side, QSFP112 or OSFP-RHS on the NIC side.
Two cautions:
- Match the optical spec, not just the name. 400G SR4 (100G per lane, IEEE 802.3db) does not interoperate with SR8 (8 × 50G) or with BiDi variants. Check the standard listed on both datasheets.
- Breakout is a separate decision. One 800G DR8 port can feed two 400G DR4 NIC ports over an MPO split, but only if the switch software supports that breakout mode.
Buyer's checklist before you order 400G optics
- Host port type: QSFP-DD, QSFP112, finned OSFP or OSFP-RHS? Check the switch or NIC datasheet, not the marketing speed.
- Host lane rate: 50G or 100G per electrical lane?
- Optical spec and reach: SR4, VR4, DR4, DR4+ or FR4, and the IEEE clause on both ends of the link.
- Fiber and connector: OM3/OM4 or OS2, MPO-12 APC or LC duplex, polarity.
- Coding: the host platform and software or firmware version, so we can check coding and compatibility for that host.
- Thermal and power: the port power class and the airflow direction in the chassis.
How YYGL Optical can help
YYGL Optical supplies 400G modules in QSFP-DD, QSFP112 and OSFP-RHS, along with 800G and 1.6T optics. Compatibility depends on the host platform. Please share your switch model, software version, module type, link distance and fiber type so we can check coding and compatibility before you order.
YYGL Optical is an independent optics supplier; we are not those brands and we do not claim affiliation with them.
Looking for High-Speed Optics for Your AI Clusters or Data Center Upgrades?
YYGL Optical engineers and manufactures high-performance 10G to 1.6T transceivers (OSFP, QSFP-DD, SFP+) pre-coded and 100% tested for Arista, Cisco, NVIDIA Mellanox, and Juniper switches. Evaluation samples and direct factory wholesale pricing are available for network engineering teams.