{"title":"10G SFP+ Optical Transceivers","description":"\u003cp\u003eHigh-reliability enterprise 10G SFP+ optical transceivers (SR, LR, ER, ZR) with DOM diagnostics and wide switch interoperability.\u003c\/p\u003e","products":[{"product_id":"10g-sfp-plus-sr-850nm-300m-dom-lc-duplex-multimode-optical-module-transceiver","title":"YYGL 10G SFP+ SR 850nm 300m LC Duplex Multimode Optical Transceiver","description":"\u003ch2\u003e10G SFP+ SR Multimode Optical Module | 850nm | 300m | DOM | LC Duplex\u003c\/h2\u003e\u003cp\u003eThe YYGL 10G SFP+ SR optical module is designed for short-reach multimode fiber transmission in enterprise data centers and campus networks. Operating at \u003cstrong\u003e850nm\u003c\/strong\u003e wavelength with LC Duplex interface, it supports a maximum transmission distance of \u003cstrong\u003e300 meters\u003c\/strong\u003e over OM3 multimode fiber — the ideal choice for intra-rack and inter-rack 10G connections.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e850nm VCSEL Laser:\u003c\/strong\u003e Optimized for OM3\/OM4 multimode fiber, delivering reliable short-reach 10G connectivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Optical Monitoring (DOM):\u003c\/strong\u003e Real-time monitoring of temperature, voltage, bias current, and TX\/RX optical power for simplified network operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLC Duplex Interface:\u003c\/strong\u003e Standard LC duplex connector for SFP+ ports on switches, routers, and servers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Designed to SFP+ MSA and IEEE 802.3ae specifications; coded for the host you name\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Operating Temperature Range:\u003c\/strong\u003e 0°C ~ 70°C commercial-grade temperature range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance Documents:\u003c\/strong\u003e Available per SKU on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003e10.3125 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eSFP+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e850nm (TX\/RX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Type\u003c\/td\u003e\n\u003ctd\u003eMultimode OM3\/OM4 (MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Distance\u003c\/td\u003e\n\u003ctd\u003e300m (OM3) \/ 400m (OM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eLC Duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Diagnostics\u003c\/td\u003e\n\u003ctd\u003eDOM Supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd\u003e1.0W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C ~ 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eSFP+ MSA, IEEE 802.3ae\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eWidely deployed in enterprise data center top-of-rack (ToR) interconnects, campus network aggregation, storage area networks (SAN), and 10G server connections.\u003c\/p\u003e\u003cp\u003eCoding is available for Cisco, Arista, NVIDIA Mellanox, Juniper, or Dell hosts. Compatibility depends on the host platform. Please share your switch model, software version, module type, link distance and fiber type so we can check coding and compatibility before you order. Each module is tested before it ships. YYGL Optical is an independent optics supplier; we are not those brands and we do not claim affiliation with them. Contact us for product selection assistance.\u003c\/p\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092801175636,"sku":"YY-SFP-SR-300M","price":9.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/10g-sfp-sr.jpg?v=1793931397"},{"product_id":"10g-sfp-plus-lr-1310nm-10km-dom-lc-duplex-single-mode-optical-module-transceiver","title":"YYGL 10G SFP+ LR 1310nm 10km LC Duplex Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 10G SFP+ LR 1310nm 10km LC Duplex Single-Mode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 10G SFP+ LR\u003c\/strong\u003e is an enterprise-grade 10Gbps single-mode optical transceiver engineered for robust long-reach campus networks, data center inter-rack connections, and metropolitan area network (MAN) aggregation. Operating at the standard 1310nm optical transmission window over G.652 single-mode fiber (SMF), it provides reliable transmission up to \u003cstrong\u003e10 kilometers\u003c\/strong\u003e via standard LC Duplex connectors with full digital optical monitoring (DOM) and ultra-low power consumption under 1.0W.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProven 1310nm DFB Laser Technology:\u003c\/strong\u003e Equipped with an uncooled, high-stability 1310nm Distributed Feedback (DFB) laser and high-sensitivity PIN photodetector for error-free transmission up to 10km.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUltra-Low Power Consumption:\u003c\/strong\u003e Maximum power dissipation is strictly ≤1.0W, drastically reducing thermal loads in high-density 24-port and 48-port SFP+ switch line cards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive SFF-8472 DOM Telemetry:\u003c\/strong\u003e Real-time digital diagnostics monitoring (DOM\/DDM) over I2C, tracking internal temperature, supply voltage, Tx bias current, Tx output power, and Rx received optical power.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal SFP+ Compatibility:\u003c\/strong\u003e Built in accordance with SFP+ MSA (SFF-8431) and IEEE 802.3ae 10GBASE-LR standards, ensuring hot-pluggable reliability across enterprise platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-SFP-LR-10KM\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125Gbps (10GBASE-LR) \/ 9.953Gbps (10GBASE-LW)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFP+ (Enhanced Small Form-Factor Pluggable)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1310nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode Fiber (OS2 \/ G.652 SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Transmission Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kilometers (6.2 miles)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC Duplex (UPC polish)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter \/ Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1310nm DFB Laser \/ PIN Receiver\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1.0W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFF-8431, SFF-8472, IEEE 802.3ae, RoHS-6, CE, Class 1 Laser\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (SFF-8472 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Bench Testing\u003c\/h3\u003e\n\u003cp\u003eEach YYGL Optical 10G SFP+ LR module is individually programmed and tested on OEM switch hardware before shipment. Pre-coded EEPROM configurations are available for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco:\u003c\/strong\u003e Catalyst 3850\/9300, Nexus 3000\/9000, and ASR series.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista Networks:\u003c\/strong\u003e 7050, 7150, and 7280 series switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper Networks:\u003c\/strong\u003e EX and QFX series Ethernet switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell Technologies:\u003c\/strong\u003e Networking N-Series and S-Series switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMikroTik \/ Ubiquiti:\u003c\/strong\u003e CCR, CRS, and EdgeSwitch enterprise routers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTarget Application Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCampus Backbone Links:\u003c\/strong\u003e Interconnecting core and aggregation switches across campus buildings spanning up to 10km.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eData Center Aggregation:\u003c\/strong\u003e Reliable 10G server uplinks and inter-rack connectivity where distances exceed standard multimode SR limits (300m).\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is the difference between 10G SFP+ SR and 10G SFP+ LR?\u003c\/h4\u003e\n\u003cp\u003eSR (Short Reach) operates at 850nm over multimode fiber (MMF) up to 300 meters, whereas LR (Long Reach) operates at 1310nm over single-mode fiber (SMF) up to 10 kilometers. LR is required whenever link distances exceed 300m or when connecting over single-mode campus infrastructure.\u003c\/p\u003e\n\n\u003ch4\u003eWhat optical patch cord is required for 10G LR?\u003c\/h4\u003e\n\u003cp\u003eA standard 9\/125µm single-mode duplex fiber cable (OS2) with blue LC-to-LC connectors (UPC polish) is required.\u003c\/p\u003e\n\n\u003ch4\u003eCan this 10G LR module be used on a 1km link without attenuators?\u003c\/h4\u003e\n\u003cp\u003eYes. The receiver sensitivity and maximum input power range allow direct operation from 2 meters up to 10km without the risk of receiver saturation or need for optical attenuators.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Evaluation \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eWe welcome lab evaluation requests and bulk enterprise orders. Contact YYGL Optical technical sales for coding verification, datasheets, and quantity discounts.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is the difference between 10G SFP+ SR and 10G SFP+ LR?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"SR (Short Reach) operates at 850nm over multimode fiber (MMF) up to 300 meters, whereas LR (Long Reach) operates at 1310nm over single-mode fiber (SMF) up to 10 kilometers. LR is required whenever link distances exceed 300m or when connecting over single-mode campus infrastructure.\"}},{\"@type\":\"Question\",\"name\":\"What optical patch cord is required for 10G LR?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A standard 9\/125µm single-mode duplex fiber cable (OS2) with blue LC-to-LC connectors (UPC polish) is required.\"}},{\"@type\":\"Question\",\"name\":\"Can this 10G LR module be used on a 1km link without attenuators?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. The receiver sensitivity and maximum input power range allow direct operation from 2 meters up to 10km without the risk of receiver saturation or need for optical attenuators.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092801208404,"sku":"YY-SFP-LR-10KM","price":9.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/1_37686148-49ac-45e2-865d-2eed49bcf8f7.jpg?v=1782446555"},{"product_id":"10g-sfp-plus-er-1550nm-40km-dom-lc-duplex-single-mode-optical-module-transceiver","title":"YYGL 10G SFP+ ER 1550nm 40km LC Duplex Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 10G SFP+ ER 1550nm 40km LC Duplex Single-Mode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 10G SFP+ ER\u003c\/strong\u003e is a high-performance extended-reach single-mode optical transceiver designed for metropolitan area networks (MAN), regional campus backbones, and data center interconnects (DCI). Operating at the low-attenuation 1550nm optical window over single-mode fiber (SMF), it provides reliable transmission up to \u003cstrong\u003e40 kilometers\u003c\/strong\u003e via standard LC Duplex connectors without needing optical amplifiers.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1550nm Cooled EML Laser:\u003c\/strong\u003e Utilizes an electro-absorption modulated laser (EML) operating at 1550nm where fiber attenuation is minimized (~0.2dB\/km), delivering high dispersion tolerance over 40km links.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Power Link Budget:\u003c\/strong\u003e Designed with an optical power budget exceeding 15dB, ensuring dependable signal integrity across mid-range regional fiber spans.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive SFF-8472 DOM Telemetry:\u003c\/strong\u003e Built-in digital diagnostics provide active monitoring of module temperature, supply voltage, laser bias, and Tx\/Rx optical power levels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnergy Efficient Operation:\u003c\/strong\u003e Total power dissipation strictly controlled at ≤1.5W, compatible with commercial temperature environments (0°C to 70°C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-SFP-ER-40KM\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125Gbps (10GBASE-ER)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFP+ (Enhanced Small Form-Factor Pluggable)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1550nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode Fiber (OS2 \/ G.652 SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Transmission Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kilometers (24.8 miles)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC Duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter \/ Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1550nm Cooled EML Laser \/ High-Sensitivity PIN Receiver\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFF-8431, SFF-8472, IEEE 802.3ae 10GBASE-ER, RoHS-6, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (SFF-8472 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Lab Validation\u003c\/h3\u003e\n\u003cp\u003eEach module is verified on live switch test beds for bit error rate performance (BER \u0026lt; 1E-12). Pre-coded EEPROM configurations are available for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco:\u003c\/strong\u003e Catalyst, Nexus, and ASR router series.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista Networks:\u003c\/strong\u003e 7050, 7150, and 7280 series.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper Networks:\u003c\/strong\u003e MX and QFX platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell Technologies:\u003c\/strong\u003e PowerSwitch enterprise series.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMikroTik \/ Ubiquiti:\u003c\/strong\u003e Carrier-grade routing platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTarget Application Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMetropolitan Area Networks (MAN):\u003c\/strong\u003e Direct interconnects between enterprise offices or colocation facilities spanning 10km to 40km without optical repeaters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMid-Range DCI:\u003c\/strong\u003e Data center replication and backup transport links across regional campuses.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eHow does 10G SFP+ ER differ from 10G SFP+ LR?\u003c\/h4\u003e\n\u003cp\u003eWhile 10G LR uses a 1310nm laser for distances up to 10km, 10G ER utilizes a cooled 1550nm EML laser capable of bridging up to 40km over standard single-mode fiber, making ER suitable for inter-city and metro-scale networking.\u003c\/p\u003e\n\n\u003ch4\u003eDo I need an optical attenuator when testing 10G ER on short links in a lab?\u003c\/h4\u003e\n\u003cp\u003eYes. Because the 10G ER transmitter outputs significant optical power, testing it back-to-back on a short fiber patch cable (e.g., \u0026lt;10km) requires a 5dB to 10dB optical attenuator to prevent overloading or damaging the optical receiver.\u003c\/p\u003e\n\n\u003ch4\u003eIs digital diagnostics monitoring (DOM) supported?\u003c\/h4\u003e\n\u003cp\u003eYes. Full SFF-8472 compliant DOM telemetry is built into the module, allowing continuous monitoring of laser bias, internal temperature, voltage, and optical power.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Evaluation \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eContact YYGL Optical to request sample units, verify switch hardware compatibility, or discuss bulk pricing for network infrastructure rollouts.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"How does 10G SFP+ ER differ from 10G SFP+ LR?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"While 10G LR uses a 1310nm laser for distances up to 10km, 10G ER utilizes a cooled 1550nm EML laser capable of bridging up to 40km over standard single-mode fiber, making ER suitable for inter-city and metro-scale networking.\"}},{\"@type\":\"Question\",\"name\":\"Do I need an optical attenuator when testing 10G ER on short links in a lab?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Because the 10G ER transmitter outputs significant optical power, testing it back-to-back on a short fiber patch cable (e.g., \u003c10km) requires a 5dB to 10dB optical attenuator to prevent overloading or damaging the optical receiver.\"}},{\"@type\":\"Question\",\"name\":\"Is digital diagnostics monitoring (DOM) supported?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Full SFF-8472 compliant DOM telemetry is built into the module, allowing continuous monitoring of laser bias, internal temperature, voltage, and optical power.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092801241172,"sku":"YY-SFP-ER-40KM","price":11.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/10g-sfp-er.jpg?v=1793931399"},{"product_id":"10g-sfp-plus-zr-1550nm-80km-dom-lc-duplex-single-mode-optical-module-transceiver","title":"YYGL 10G SFP+ ZR 1550nm 80km LC Duplex Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 10G SFP+ ZR 1550nm 80km LC Duplex Single-Mode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 10G SFP+ ZR\u003c\/strong\u003e is an ultra-long-reach single-mode optical transceiver engineered for telecom core backbones, cross-city regional networks, and long-distance data center interconnects (DCI). Operating at 1550nm over standard single-mode fiber (SMF), it achieves up to \u003cstrong\u003e80 kilometers\u003c\/strong\u003e transmission reach without in-line optical amplification, powered by a high-stability cooled EML laser and high-sensitivity APD receiver.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUltra-Long 80km Reach:\u003c\/strong\u003e High optical link budget (≥23dB) enables 80km point-to-point transmission over standard G.652 single-mode fiber, eliminating costly optical repeaters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Sensitivity APD Optical Receiver:\u003c\/strong\u003e Integrated Avalanche Photodiode (APD) receiver provides exceptional optical sensitivity (-24dBm), ensuring low bit error rates across long spans.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1550nm Cooled EML Transmitter:\u003c\/strong\u003e Advanced electro-absorption modulated laser (EML) with precision temperature control offers excellent chromatic dispersion tolerance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStrict Power Dissipation:\u003c\/strong\u003e Maximum power consumption is held at ≤1.5W, maintaining cool switch operation across commercial temperature ranges (0°C to 70°C).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSFF-8472 DOM Diagnostics:\u003c\/strong\u003e Real-time digital optical monitoring tracks module temperature, supply voltage, laser bias, Tx optical power, and Rx optical power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-SFP-ZR-80KM\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125Gbps (10GBASE-ZR)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFP+ (Enhanced Small Form-Factor Pluggable)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1550nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode Fiber (OS2 \/ G.652 SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Transmission Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kilometers (49.7 miles)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC Duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter \/ Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1550nm Cooled EML Laser \/ High-Sensitivity APD Receiver\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Link Budget\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥23 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFF-8431, SFF-8472, IEEE 802.3ae 10GBASE-ZR, RoHS-6, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (SFF-8472 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Lab Validation\u003c\/h3\u003e\n\u003cp\u003eEach module is verified on live switch test beds for bit error rate performance (BER \u0026lt; 1E-12). Pre-coded EEPROM configurations are available for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco:\u003c\/strong\u003e Catalyst, Nexus, and ASR router platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista Networks:\u003c\/strong\u003e 7050, 7150, and 7280 series.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper Networks:\u003c\/strong\u003e MX and QFX platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell Technologies:\u003c\/strong\u003e PowerSwitch enterprise series.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMikroTik \/ Ubiquiti:\u003c\/strong\u003e Carrier-grade routing platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTarget Application Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTelecom Backbone \u0026amp; WAN:\u003c\/strong\u003e Ultra-long distance regional transport connecting metropolitan points of presence (PoPs) up to 80km.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDisaster Recovery DCI:\u003c\/strong\u003e Synchronous or asynchronous data replication across geographically dispersed enterprise data centers.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is the difference between 10G SFP+ ER and 10G SFP+ ZR?\u003c\/h4\u003e\n\u003cp\u003e10G ER is rated for up to 40km reach using a standard PIN receiver, whereas 10G ZR is rated for up to 80km reach by combining a cooled EML laser with an Avalanche Photodiode (APD) receiver for superior optical sensitivity and link budget (≥23dB).\u003c\/p\u003e\n\n\u003ch4\u003eDo I need optical attenuators when testing 10G ZR on short fiber spans?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eYes, absolutely.\u003c\/strong\u003e An APD receiver can be permanently damaged by high optical input power. When testing in a laboratory or over links shorter than 20km, you MUST insert a 10dB to 15dB optical attenuator between the transmitter and receiver.\u003c\/p\u003e\n\n\u003ch4\u003eWhat optical patch cord is required?\u003c\/h4\u003e\n\u003cp\u003eUse a standard OS2 9\/125µm single-mode duplex fiber cable with LC Duplex connectors (UPC polish).\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Evaluation \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eContact YYGL Optical to request sample units, verify switch hardware compatibility, or discuss bulk pricing for carrier and enterprise network infrastructure.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is the difference between 10G SFP+ ER and 10G SFP+ ZR?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"10G ER is rated for up to 40km reach using a standard PIN receiver, whereas 10G ZR is rated for up to 80km reach by combining a cooled EML laser with an Avalanche Photodiode (APD) receiver for superior optical sensitivity and link budget (≥23dB).\"}},{\"@type\":\"Question\",\"name\":\"Do I need optical attenuators when testing 10G ZR on short fiber spans?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes, absolutely. An APD receiver can be permanently damaged by high optical input power. When testing in a laboratory or over links shorter than 20km, you MUST insert a 10dB to 15dB optical attenuator between the transmitter and receiver.\"}},{\"@type\":\"Question\",\"name\":\"What optical patch cord is required?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Use a standard OS2 9\/125µm single-mode duplex fiber cable with LC Duplex connectors (UPC polish).\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092801273940,"sku":"YY-SFP-ZR-80KM","price":8.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/10g-sfp-zr.jpg?v=1793931401"}],"url":"https:\/\/yiyuanguanglink.com\/de\/collections\/10g-sfp-plus-optical-transceivers.oembed","provider":"YYGL Optical","version":"1.0","type":"link"}