{"title":"Optical Transceivers","description":"\u003cp\u003eExplore YYGL Optical's comprehensive portfolio of high-speed optical transceivers from 10G SFP+ to 1.6T OSFP224. Engineered for AI GPU compute clusters, hyperscale data centers, and multi-vendor switch environments with 100% pre-coded testing.\u003c\/p\u003e","products":[{"product_id":"1-6t-2xdr4-dr8-osfp224-pam4-1310nm-500m-dom-dual-mpo-12-apc-single-mode-optical-module","title":"YYGL 1.6T OSFP224 DR4\/DR8 1310nm 500m MPO-12 Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 1.6T OSFP224 DR4\/DR8 1310nm 500m MPO-12 Single-Mode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 1.6T OSFP224 DR4\/DR8\u003c\/strong\u003e optical transceiver is purpose-built for ultra-scale next-generation AI computing clusters, high-density 51.2T\/102.4T spine-leaf fabrics, and hyperscale data center interconnects (DCI). Operating at 1310nm over standard single-mode fiber (SMF) up to 500 meters, it delivers massive \u003cstrong\u003e1.6Tbps aggregate throughput\u003c\/strong\u003e via 8×200G PAM4 electrical lanes and dual 4×200G optical lanes, engineered with Silicon Photonics (SiPh) technology for minimal latency and strict power consumption under 24W.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e224G SerDes Architecture for AI Superclusters:\u003c\/strong\u003e Powered by native 8×200G PAM4 electrical lanes (224Gbps\/lane SerDes), delivering unprecedented throughput to eliminate GPU communication bottlenecks in massive LLM training fabrics (e.g., NVIDIA Blackwell B200 \/ GB200 architectures).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSilicon Photonics (SiPh) Integration:\u003c\/strong\u003e Monolithic integration of optical modulators and waveguides provides superior thermal stability, high optical return loss, and reduced component count for enhanced reliability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Dual 800G Breakout:\u003c\/strong\u003e Optical interface features Dual MPO-12\/APC connectors supporting full 1.6Tbps point-to-point links or seamless optical breakout into two independent 800G OSFP\/QSFP-DD DR4 links.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuperior Energy Efficiency:\u003c\/strong\u003e Power dissipation is strictly controlled at ≤24W (approx. 15 pJ\/bit), easing cooling loads in high-density 1RU\/2RU switch chassis.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Telemetry \u0026amp; CMIS 5.2:\u003c\/strong\u003e Complete digital optical monitoring (DOM) over the I2C interface, enabling real-time telemetry for operating temperature, supply voltage, laser bias currents, and Tx\/Rx optical power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-1.6T-OSFP224-DR8-500M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.6Tbps (8×200G PAM4 Electrical \/ Dual 4×200G Optical)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSFP224 (Finned Top \/ Flat Top available)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1310nm Parallel Single-Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode Fiber (OS2 \/ G.652 SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 500 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual MPO-12\/APC (MTP-12 APC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSilicon Photonics (SiPh) Integrated Modulator Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReceiver Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-Speed PIN Photodetector Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤24.0W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCMIS Rev 5.2 (Common Management Interface Specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSFP MSA, IEEE 802.3ck, IEEE 802.3bs, RoHS-6, CE, Class 1 Laser\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (Real-time I2C Diagnostics)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eGenerational Comparison: 1.6T vs 800G vs 400G\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse; margin-top: 10px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f7f7f7; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eFeature\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e1.6T OSFP224 DR8 (This Model)\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e800G OSFP DR8\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e400G QSFP-DD DR4\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eLane Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e8×200G PAM4 (224G SerDes)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e8×100G PAM4 (112G SerDes)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e4×100G PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePer-Port Throughput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e1,600 Gbps\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e800 Gbps\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e400 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eMax SMF Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e500m\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e500m\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e500m\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e~15 pJ\/bit (≤24W)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e~20 pJ\/bit (≤16W)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e~30 pJ\/bit (≤12W)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eTarget Fabric\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eNext-Gen GPU Superclusters\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eGPU Compute Fabrics\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eEnterprise Spine-Leaf \/ DCI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Lab Validation\u003c\/h3\u003e\n\u003cp\u003eEach YYGL Optical 1.6T OSFP224 transceiver undergoes 100% full-rate burn-in, optical eye pattern testing on high-speed digital sampling oscilloscopes, and bit error rate validation (BER \u0026lt; 1E-12). Pre-coded EEPROM configurations are available for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNVIDIA Mellanox:\u003c\/strong\u003e Quantum-X InfiniBand and Spectrum-X Ethernet AI platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista Networks:\u003c\/strong\u003e Next-generation 7060X series 51.2T\/102.4T platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco Systems:\u003c\/strong\u003e Nexus 9000 Series AI cloud fabrics.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper Networks:\u003c\/strong\u003e PTX Series high-capacity core routers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell Technologies:\u003c\/strong\u003e PowerSwitch enterprise AI data center switches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat does OSFP224 mean and how does it achieve 1.6Tbps?\u003c\/h4\u003e\n\u003cp\u003eOSFP224 refers to the OSFP form factor running with 224Gbps electrical SerDes per lane. By combining 8 parallel electrical lanes running at 212.5Gbps PAM4, the module delivers an aggregate bidirectional throughput of 1.6Tbps (1600Gbps) without requiring external gearbox chips.\u003c\/p\u003e\n\n\u003ch4\u003eCan this 1.6T module break out into two 800G links?\u003c\/h4\u003e\n\u003cp\u003eYes. Because the optical interface utilizes Dual MPO-12\/APC connectors (each carrying 4x200G PAM4 lanes), it can be connected directly to two separate 800G OSFP DR4 or 800G QSFP-DD DR4 transceivers using standard structured cabling.\u003c\/p\u003e\n\n\u003ch4\u003eWhat optical patch cord is required?\u003c\/h4\u003e\n\u003cp\u003eIt requires two standard MPO-12\/APC single-mode fiber patch cables (OS2 single-mode). Both connectors must feature APC (Angled Physical Contact) 8-degree polish to maintain optical return loss above 50dB.\u003c\/p\u003e\n\n\u003ch4\u003eHow is heat managed at 24W power consumption?\u003c\/h4\u003e\n\u003cp\u003eThe module integrates high-efficiency Silicon Photonics modulators with an optimized OSFP finned-top heat sink, engineered to operate seamlessly within standard front-to-back switch cooling architectures at case temperatures up to 70°C.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Evaluation \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eWe provide lab evaluation samples with real-bench optical test reports (eye diagram metrics, BER logs, and switch link tests). Contact YYGL Optical sales engineering for compatibility checks and volume enterprise pricing.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What does OSFP224 mean and how does it achieve 1.6Tbps?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"OSFP224 refers to the OSFP form factor running with 224Gbps electrical SerDes per lane. By combining 8 parallel electrical lanes running at 212.5Gbps PAM4, the module delivers an aggregate bidirectional throughput of 1.6Tbps (1600Gbps) without requiring external gearbox chips.\"}},{\"@type\":\"Question\",\"name\":\"Can this 1.6T module break out into two 800G links?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Because the optical interface utilizes Dual MPO-12\/APC connectors (each carrying 4x200G PAM4 lanes), it can be connected directly to two separate 800G OSFP DR4 or 800G QSFP-DD DR4 transceivers using standard structured cabling.\"}},{\"@type\":\"Question\",\"name\":\"What optical patch cord is required?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It requires two standard MPO-12\/APC single-mode fiber patch cables (OS2 single-mode). Both connectors must feature APC (Angled Physical Contact) 8-degree polish to maintain optical return loss above 50dB.\"}},{\"@type\":\"Question\",\"name\":\"How is heat managed at 24W power consumption?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The module integrates high-efficiency Silicon Photonics modulators with an optimized OSFP finned-top heat sink, engineered to operate seamlessly within standard front-to-back switch cooling architectures at case temperatures up to 70°C.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47086753710164,"sku":"YY-OSFP224-DR4DR8-500M","price":2476.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/1_e5064ec2-638c-4564-ab2a-ab40c0447ac4.jpg?v=1781523238"},{"product_id":"800g-osfp-sr8-pam4-850nm-100m-dom-dual-mpo-12-apc-multimode-optical-module","title":"YYGL 800G OSFP SR8 850nm 100m MPO-12 Multimode Optical Transceiver","description":"\u003ch2\u003eYYGL 800G OSFP SR8 Multimode Optical Transceiver (8×100G PAM4, 850nm, 100m, Dual MPO-12\/APC, CMIS 5.2)\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eYYGL 800G OSFP SR8\u003c\/strong\u003e is a high-performance, low-power optical transceiver engineered specifically for hyperscale AI computing clusters, GPU fabrics, and high-density spine-leaf architectures. Utilizing an 8-channel 100G PAM4 VCSEL transmitter array and PIN receiver architecture, it provides an aggregate bandwidth of \u003cstrong\u003e800Gbps\u003c\/strong\u003e over OM4 multimode fiber (MMF) up to 100 meters, with low transmission latency.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Bandwidth for AI Fabrics:\u003c\/strong\u003e 800Gbps aggregate throughput (8×100Gbps PAM4 channels), purpose-built for massive AI\/ML model training and HPC workloads.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Maximum power consumption strictly controlled at \u003cstrong\u003e≤16W\u003c\/strong\u003e, significantly reducing GPU cluster cooling overhead.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Management:\u003c\/strong\u003e Supports standard CMIS Rev 5.2 with Digital Optical Monitoring (DOM\/DDM) for real-time laser bias, temperature, voltage, and optical power telemetry.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard OSFP Form Factor:\u003c\/strong\u003e Compliant with OSFP MSA Rev 5.0 and IEEE 802.3db standards, hot-pluggable with finned top heat sink design.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Density Optical Interface:\u003c\/strong\u003e Dual MPO-12\/APC (or optional MPO-16\/APC) connector for structured multimode cabling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eValue \/ Parameter\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eYY-OSFP-SR8-100M\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e800Gbps (8×106.25Gbps PAM4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eOSFP (Finned top \/ Flat top available)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e850nm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Transmitter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e8-Channel VCSEL Array\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Receiver\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003ePIN Photodetector Array\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eMultimode Fiber (OM3 \/ OM4 MMF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eMaximum Reach\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e100m over OM4 MMF \/ 60m over OM3 MMF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eDual MPO-12\/APC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e≤16W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e3.3V DC Single Supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e0°C to 70°C (32°F to 158°F) Commercial\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eCommon Management Interface Specification (CMIS) Rev 5.2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eStandards \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eOSFP MSA Rev 5.0, CMIS Rev 5.2, IEEE 802.3db\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eDigital Diagnostics (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eSupported (Real-time monitoring via I2C)\u003c\/td\u003e\n    \u003c\/tr\u003e\n      \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eModulation (Electrical Port)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e8x100G-PAM4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eModulation (Optical Port)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eDual 4x100G-PAM4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eCoding Available For\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eCisco, Arista, NVIDIA Mellanox, Juniper, Dell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eCompliance Documents\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eAvailable per SKU on request\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHost Coding \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003eEach YYGL 800G OSFP SR8 module goes through full-rate burn-in and optical eye diagram testing before shipment. Coding is available for Cisco, Arista, NVIDIA Mellanox, Juniper, or Dell hosts. Compatibility depends on the host platform. Please share your switch model, software version, module type, link distance and fiber type so we can check coding and compatibility before you order. YYGL Optical is an independent optics supplier; we are not those brands and we do not claim affiliation with them.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\" data-yygl-faq-version=\"p1-20261106\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat data rate and form factor does this module use?\u003c\/h4\u003e\n\u003cp\u003eThe listing specifies 800Gbps in the OSFP form factor.\u003c\/p\u003e\n\u003ch4\u003eWhich fiber, wavelength, and reach are specified?\u003c\/h4\u003e\n\u003cp\u003eIt uses 850nm over OM3\/OM4 multimode fiber. The listed reach is 100m on OM4 or 60m on OM3.\u003c\/p\u003e\n\u003ch4\u003eWhich optical connector is specified for this SKU?\u003c\/h4\u003e\n\u003cp\u003eThe listed optical interface is Dual MPO-12\/APC.\u003c\/p\u003e\n\u003ch4\u003eDoes it support digital optical monitoring, and what power is listed?\u003c\/h4\u003e\n\u003cp\u003eDOM is supported. The specification lists power consumption of ≤16W.\u003c\/p\u003e\n\u003ch4\u003eWhich switch brands are named on this product page?\u003c\/h4\u003e\n\u003cp\u003eNamed brands include Cisco, Arista, NVIDIA Mellanox, Juniper, and Dell.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eOrdering \u0026amp; RFQ Information\u003c\/h3\u003e\n\u003cp\u003eWe welcome wholesale inquiries, lab evaluation sample requests, and OEM\/ODM projects. Contact our engineering and sales team for volume pricing, coding and compatibility checks, and lead times.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What data rate and form factor does this module use?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The listing specifies 800Gbps in the OSFP form factor.\"}}, {\"@type\": \"Question\", \"name\": \"Which fiber, wavelength, and reach are specified?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It uses 850nm over OM3\/OM4 multimode fiber. The listed reach is 100m on OM4 or 60m on OM3.\"}}, {\"@type\": \"Question\", \"name\": \"Which optical connector is specified for this SKU?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The listed optical interface is Dual MPO-12\/APC.\"}}, {\"@type\": \"Question\", \"name\": \"Does it support digital optical monitoring, and what power is listed?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"DOM is supported. The specification lists power consumption of ≤16W.\"}}, {\"@type\": \"Question\", \"name\": \"Which switch brands are named on this product page?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Named brands include Cisco, Arista, NVIDIA Mellanox, Juniper, and Dell.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092800815188,"sku":"YY-OSFP-SR8-100M","price":685.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/800g-osfp-sr8.jpg?v=1793931421"},{"product_id":"800g-osfp-vr8-pam4-850nm-50m-dom-dual-mpo-12-apc-multimode-optical-module","title":"YYGL 800G OSFP VR8 850nm 50m MPO-12 Multimode Optical Transceiver","description":"\u003ch2\u003eYYGL 800G OSFP VR8 Multimode Optical Transceiver | PAM4 | 850nm | 50m | Dual MPO-12\/APC\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 800G OSFP VR8\u003c\/strong\u003e transceiver delivers 800Gbps over \u003cstrong\u003e50 meters of OM4 multimode fiber\u003c\/strong\u003e using PAM4 modulation with 8×100G parallel channels. Engineered for ultra-short-reach intra-rack and top-of-rack switch connections in AI compute clusters and hyperscale data centers.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e800Gbps Bandwidth:\u003c\/strong\u003e 8×100G PAM4 parallel architecture for AI and HPC workloads.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e50m Reach:\u003c\/strong\u003e Optimized for intra-rack and adjacent-rack deployments over OM4 MMF (30m over OM3).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e850nm VCSEL Array:\u003c\/strong\u003e Low-cost, high-reliability light source for multimode applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual MPO-12\/APC:\u003c\/strong\u003e Standard connector for broad switch and server compatibility.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOSFP MSA Compliant:\u003c\/strong\u003e Fully compliant with OSFP MSA and CMIS Rev 5.2.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C ~ 70°C commercial grade.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; background-color: #f4f6f8; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; background-color: #f4f6f8; text-align: left;\"\u003eValue \/ Parameter\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eYY-OSFP-VR8-50M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e800Gbps (8×100G PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eOSFP\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Transmitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e8-Channel VCSEL Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003ePIN Photodetector Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eMultimode Fiber (OM3 \/ OM4 MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eMaximum Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e50m over OM4 \/ 30m over OM3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eDual MPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e≤16W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e3.3V DC Single Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e0°C to 70°C (32°F to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eCMIS Rev 5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eStandards \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eOSFP MSA, IEEE 802.3db\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eDigital Diagnostics (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eHost Coding Available For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eCisco, Arista, NVIDIA Mellanox, Juniper, Dell\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eCompliance Documents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eAvailable per SKU on request\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHost Coding \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003eEach YYGL 800G OSFP VR8 module undergoes full-rate burn-in and optical eye diagram testing before shipment. Coding is available for Cisco, Arista, NVIDIA Mellanox, Juniper, or Dell hosts. Compatibility depends on the host platform. Please share your switch model, software version, module type, link distance, and fiber type so we can verify coding before shipment.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat data rate and form factor does this module use?\u003c\/h4\u003e\n\u003cp\u003eThe module operates at 800Gbps (8×100G PAM4) in the standard OSFP form factor.\u003c\/p\u003e\n\u003ch4\u003eWhich fiber, wavelength, and reach are specified?\u003c\/h4\u003e\n\u003cp\u003eIt operates at 850nm over OM4 multimode fiber up to 50 meters (30 meters over OM3).\u003c\/p\u003e\n\u003ch4\u003eWhich optical connector is specified for this SKU?\u003c\/h4\u003e\n\u003cp\u003eThe optical interface uses Dual MPO-12\/APC connectors.\u003c\/p\u003e\n\u003ch4\u003eDoes it support DOM telemetry and what is the power consumption?\u003c\/h4\u003e\n\u003cp\u003eYes, Digital Optical Monitoring (DOM) is fully supported, and power consumption is ≤16W.\u003c\/p\u003e\n\u003ch4\u003eWhich switch brands are supported?\u003c\/h4\u003e\n\u003cp\u003eSupported hosts include Cisco, Arista, NVIDIA Mellanox, Juniper, and Dell switches.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eOrdering \u0026amp; RFQ Information\u003c\/h3\u003e\n\u003cp\u003eWe welcome wholesale inquiries, lab evaluation sample requests, and OEM\/ODM projects. Contact our engineering and sales team for volume pricing, coding compatibility checks, and lead times.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What data rate and form factor does this module use?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The module operates at 800Gbps (8×100G PAM4) in the standard OSFP form factor.\"}}, {\"@type\": \"Question\", \"name\": \"Which fiber, wavelength, and reach are specified?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It operates at 850nm over OM4 multimode fiber up to 50 meters (30 meters over OM3).\"}}, {\"@type\": \"Question\", \"name\": \"Which optical connector is specified for this SKU?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The optical interface uses Dual MPO-12\/APC connectors.\"}}, {\"@type\": \"Question\", \"name\": \"Does it support DOM telemetry and what is the power consumption?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes, Digital Optical Monitoring (DOM) is fully supported, and power consumption is ≤16W.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092800847956,"sku":"YY-OSFP-VR8-50M","price":1348.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/800g-osfp-vr8.jpg?v=1793931424"},{"product_id":"800g-osfp-2xfr4-fr8-pam4-1310nm-2km-dom-lc-duplex-single-mode-optical-module","title":"YYGL 800G OSFP FR4\/FR8 1310nm 2km Dual Duplex LC Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL 800G OSFP FR4\/FR8 Single-Mode Optical Transceiver | 1310nm | 2km | Dual Duplex LC | DOM\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 800G OSFP FR4\/FR8\u003c\/strong\u003e dual-port transceiver delivers \u003cstrong\u003e2×400G\u003c\/strong\u003e over single-mode fiber at \u003cstrong\u003e1310nm with 2km reach\u003c\/strong\u003e, utilizing dual duplex LC connectors. Purpose-built for data center interconnect (DCI), campus backbone, and inter-building links where longer reach and single-mode fiber are required.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Port 800G:\u003c\/strong\u003e 2×400G FR4\/FR8 architecture maximizing port density for DCI applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e2km SMF Reach:\u003c\/strong\u003e Ideal for inter-building and campus-scale data center interconnects.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1310nm WDM:\u003c\/strong\u003e CWDM \/ WDM design for single-mode fiber efficiency.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Duplex LC Connector:\u003c\/strong\u003e Universal interface compatible with standard SMF patch panels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDOM Supported:\u003c\/strong\u003e Real-time optical power, temperature, and voltage telemetry.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOSFP MSA Compliant:\u003c\/strong\u003e Fully compliant with OSFP MSA and CMIS Rev 5.2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; background-color: #f4f6f8; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; background-color: #f4f6f8; text-align: left;\"\u003eValue \/ Parameter\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eYY-OSFP-2xFR4-2KM\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e800Gbps (2×400Gbps PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eOSFP (Dual-Port)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e1310nm (CWDM4 \/ WDM)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Transmitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eSilicon Photonics (SiPh) \/ EML\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003ePIN Photodetector Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eSingle-Mode Fiber (SMF, G.652)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eMaximum Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e2km over SMF\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eDual Duplex LC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e≤16W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e3.3V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e0°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eCMIS Rev 5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eStandards \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eOSFP MSA, IEEE 802.3bs\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eDigital Diagnostics (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eHost Coding Available For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eCisco, Arista, NVIDIA Mellanox, Juniper, Dell\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eCompliance Documents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eAvailable per SKU on request\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHost Coding \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003eEach module undergoes rigorous bit error rate (BER) and optical eye diagram testing prior to dispatch. Pre-coding is available for Cisco, Arista, NVIDIA Mellanox, Juniper, or Dell hosts.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat data rate and form factor does this module use?\u003c\/h4\u003e\n\u003cp\u003eIt provides 800Gbps aggregate throughput configured as dual-port 2×400G in an OSFP package.\u003c\/p\u003e\n\u003ch4\u003eWhich fiber, wavelength, and reach are specified?\u003c\/h4\u003e\n\u003cp\u003eIt operates at 1310nm CWDM over standard single-mode fiber (SMF) up to 2 kilometers.\u003c\/p\u003e\n\u003ch4\u003eWhich optical connector is used?\u003c\/h4\u003e\n\u003cp\u003eIt features Dual Duplex LC optical connectors, compatible with standard LC patch panels.\u003c\/p\u003e\n\u003ch4\u003eDoes it support digital optical monitoring?\u003c\/h4\u003e\n\u003cp\u003eYes, DOM is fully supported via standard CMIS 5.2 telemetry, with power dissipation ≤16W.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eOrdering \u0026amp; RFQ Information\u003c\/h3\u003e\n\u003cp\u003eContact YYGL Optical for wholesale quotes, sample evaluation requests, and custom host coding requirements.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What data rate and form factor does this module use?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It provides 800Gbps aggregate throughput configured as dual-port 2×400G in an OSFP package.\"}}, {\"@type\": \"Question\", \"name\": \"Which fiber, wavelength, and reach are specified?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It operates at 1310nm CWDM over standard single-mode fiber (SMF) up to 2 kilometers.\"}}, {\"@type\": \"Question\", \"name\": \"Which optical connector is used?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It features Dual Duplex LC optical connectors, compatible with standard LC patch panels.\"}}, {\"@type\": \"Question\", \"name\": \"Does it support digital optical monitoring?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes, DOM is fully supported via standard CMIS 5.2 telemetry, with power dissipation ≤16W.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092800880724,"sku":"YY-OSFP-FR4FR8-2KM","price":685.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/800g-osfp-2xfr4.jpg?v=1793931430"},{"product_id":"800g-osfp-dr8-plus-pam4-1310nm-2km-dom-dual-mpo-12-apc-single-mode-optical-module","title":"YYGL 800G OSFP DR8+ 1310nm 2km MPO-12 Single-Mode Optical Transceiver","description":"\u003ch2\u003e800G OSFP DR8+ Single-Mode Optical Module | PAM4 | 1310nm | 2km | DOM | Dual MPO-12\/APC\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 800G OSFP DR8+\u003c\/strong\u003e optical module is engineered for hyperscale data centers, AI computing clusters, and high-performance computing (HPC) interconnects. Built on PAM4 modulation with an \u003cstrong\u003e8×100G\u003c\/strong\u003e parallel channel architecture, it delivers 800G aggregate bandwidth over single-mode fiber with a maximum reach of \u003cstrong\u003e2 kilometers\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUltra-High Bandwidth:\u003c\/strong\u003e 800Gbps aggregate throughput supporting 8×100G independent parallel transmission.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDR8+ Extended Reach:\u003c\/strong\u003e Up to 2km over single-mode fiber (SMF), extending beyond standard DR8 500m reach.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePAM4 Modulation:\u003c\/strong\u003e High spectral efficiency, low BER, and stable link performance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDigital Optical Monitoring (DOM):\u003c\/strong\u003e Real-time monitoring of temperature, voltage, and optical power.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual MPO-12\/APC Interface:\u003c\/strong\u003e Standard dual MPO-12\/APC connectors compatible with mainstream SMF cabling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOSFP Form Factor:\u003c\/strong\u003e High-density OSFP package designed for high-density switches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; background-color: #f4f6f8; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; background-color: #f4f6f8; text-align: left;\"\u003eValue \/ Parameter\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eYY-OSFP-DR8PLUS-2KM\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e800Gbps (8×100Gbps PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eOSFP\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e1310nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Transmitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eSilicon Photonics (SiPh) \/ EML Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003ePIN Photodetector Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eSingle-Mode Fiber (SMF, G.652)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eMaximum Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e2km over SMF\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eDual MPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e≤16W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e3.3V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e0°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eCMIS Rev 5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eStandards \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eOSFP MSA, IEEE 802.3bs\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eDigital Diagnostics (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eHost Coding Available For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eCisco, Arista, NVIDIA Mellanox, Juniper, Dell\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eCompliance Documents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eAvailable per SKU on request\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHost Coding \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003eCoding is available for Cisco, Arista, NVIDIA Mellanox, Juniper, or Dell hosts. Compatibility depends on the host platform. Each module is 100% pre-coded and tested on OEM host switches before shipping.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is the reach of 800G OSFP DR8+ compared to standard DR8?\u003c\/h4\u003e\n\u003cp\u003eStandard 800G DR8 covers up to 500m; this DR8+ model extends reach up to 2km over single-mode fiber.\u003c\/p\u003e\n\u003ch4\u003eWhich fiber connector is used?\u003c\/h4\u003e\n\u003cp\u003eThe module uses Dual MPO-12\/APC connectors for 8 parallel single-mode channels.\u003c\/p\u003e\n\u003ch4\u003eIs it compatible with NVIDIA Mellanox and Arista AI clusters?\u003c\/h4\u003e\n\u003cp\u003eYes, modules are pre-coded for NVIDIA Quantum-2\/Spectrum-4 and Arista 7060X5 switches.\u003c\/p\u003e\n\u003ch4\u003eWhat is the power consumption?\u003c\/h4\u003e\n\u003cp\u003ePower consumption is controlled at ≤16W with advanced thermal dissipation.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eOrdering \u0026amp; RFQ Information\u003c\/h3\u003e\n\u003cp\u003eContact YYGL Optical for volume pricing, compatibility verifications, or sample testing requests.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the reach of 800G OSFP DR8+ compared to standard DR8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Standard 800G DR8 covers up to 500m; this DR8+ model extends reach up to 2km over single-mode fiber.\"}}, {\"@type\": \"Question\", \"name\": \"Which fiber connector is used?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The module uses Dual MPO-12\/APC connectors for 8 parallel single-mode channels.\"}}, {\"@type\": \"Question\", \"name\": \"What is the power consumption?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Power consumption is controlled at ≤16W with advanced thermal dissipation.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092800913492,"sku":"YY-OSFP-DR8P-2KM","price":1348.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/800g-osfp-dr8-plus.jpg?v=1793931420"},{"product_id":"800g-qsfp-dd-sr8-pam4-850nm-100m-dom-single-mpo-16-apc-multimode-optical-module","title":"YYGL 800G QSFP-DD SR8 850nm 100m MPO-16 Multimode Optical Transceiver","description":"\u003ch2\u003eYYGL 800G QSFP-DD SR8 Multimode Optical Transceiver | PAM4 | 850nm | 100m | Single MPO-16\/APC | DOM\u003c\/h2\u003e\n\u003cp\u003eThe YYGL 800G QSFP-DD SR8 optical transceiver delivers \u003cstrong\u003e800Gbps over up to 100 meters of OM4 multimode fiber\u003c\/strong\u003e using 8×100G PAM4 parallel channels. Engineered with a single MPO-16\/APC optical interface and low-power VCSEL architecture (≤15W), it suits high-density AI GPU compute clusters and spine-leaf fabrics.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e800Gbps in QSFP-DD 800:\u003c\/strong\u003e High-density form factor conforming to QSFP-DD MSA and CMIS Rev 5.2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100m Reach over OM4:\u003c\/strong\u003e Covers inter-rack and intra-rack high-speed links in AI clusters (60m over OM3).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Consumes ≤15W to prevent switch chassis overheating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle MPO-16\/APC Interface:\u003c\/strong\u003e Simplifies fiber patch management and minimizes optical insertion loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePAM4 8×100G Architecture:\u003c\/strong\u003e High-efficiency 850nm VCSEL transmitter array with low Bit Error Rate (BER).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Optical Monitoring (DOM):\u003c\/strong\u003e Real-time I2C telemetry for optical power, temperature, and voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreakout Capable:\u003c\/strong\u003e Supports native 800GBASE-SR8 or breakout to 2x 400G SR4.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse: collapse; margin-top: 10px; margin-bottom: 15px;\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 8px; text-align: left; background-color: #f7f7f7;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding: 8px; text-align: left; background-color: #f7f7f7;\"\u003eTechnical Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eProduct Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eYYGL YY-QSFPDD-SR8-100M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eQSFP-DD 800 (Double Density)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e800 Gbps (8×106.25 Gbps PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e850nm VCSEL Array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eMax Transmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eUp to 100m over OM4 MMF (60m over OM3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eMPO-16 \/ APC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eTransmitter \/ Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e8-Channel 850nm VCSEL \/ PIN Photodetector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e≤15W (Low-Power Thermal Design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eIEEE 802.3db (800GBASE-SR8), QSFP-DD MSA, CMIS Rev 5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eDigital Diagnostics (DDM\/DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eSupported via I2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eCommercial: 0°C to 70°C (32°F to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eCoding Available For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eCisco, Arista, NVIDIA Mellanox, Juniper, Dell (checked for your switch model before you order)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eMultimode MMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eModulation (Electrical Port)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e8x100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eModulation (Optical Port)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e8x100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eCoding Available For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eCisco, Arista, NVIDIA Mellanox, Juniper, Dell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eCompliance Documents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eAvailable per SKU on request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\" data-yygl-faq-version=\"p1-20261106\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat data rate and form factor does this module use?\u003c\/h4\u003e\n\u003cp\u003eThe listing specifies 800Gbps in the QSFP-DD 800 form factor.\u003c\/p\u003e\n\u003ch4\u003eWhich fiber, wavelength, and reach are specified?\u003c\/h4\u003e\n\u003cp\u003eIt uses 850nm over multimode fiber. The listed reach is 100m on OM4 or 60m on OM3.\u003c\/p\u003e\n\u003ch4\u003eWhich optical connector is specified for this SKU?\u003c\/h4\u003e\n\u003cp\u003eThe listed optical interface is Single MPO-16\/APC.\u003c\/p\u003e\n\u003ch4\u003eDoes it support digital optical monitoring, and what power is listed?\u003c\/h4\u003e\n\u003cp\u003eDOM is supported. The specification lists power consumption of ≤15W.\u003c\/p\u003e\n\u003ch4\u003eWhich switch brands are named on this product page?\u003c\/h4\u003e\n\u003cp\u003eNamed brands include Cisco, Arista, NVIDIA Mellanox, Juniper, and Dell.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAI\/ML training cluster GPU-to-switch interconnects\u003c\/li\u003e\n\u003cli\u003eHyperscale data center leaf-spine fabric (100m reach)\u003c\/li\u003e\n\u003cli\u003eHigh-density top-of-rack switching deployments\u003c\/li\u003e\n\u003cli\u003eHPC intra-cluster high-bandwidth links\u003c\/li\u003e\n\u003cli\u003eCloud provider scale-out networking\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCoding, Compatibility \u0026amp; Testing\u003c\/h3\u003e\n\u003cp\u003eCoding is available for Cisco, Arista, NVIDIA Mellanox, Juniper, or Dell hosts. Compatibility depends on the host platform. Please share your switch model, software version, module type, link distance and fiber type so we can check coding and compatibility before you order. Each module is checked for insertion loss, eye diagram margin, and optical power before dispatch. YYGL Optical is an independent optics supplier; we are not those brands and we do not claim affiliation with them. Contact us for volume pricing or OEM evaluation units.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What data rate and form factor does this module use?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The listing specifies 800Gbps in the QSFP-DD 800 form factor.\"}}, {\"@type\": \"Question\", \"name\": \"Which fiber, wavelength, and reach are specified?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It uses 850nm over multimode fiber. The listed reach is 100m on OM4 or 60m on OM3.\"}}, {\"@type\": \"Question\", \"name\": \"Which optical connector is specified for this SKU?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The listed optical interface is Single MPO-16\/APC.\"}}, {\"@type\": \"Question\", \"name\": \"Does it support digital optical monitoring, and what power is listed?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"DOM is supported. The specification lists power consumption of ≤15W.\"}}, {\"@type\": \"Question\", \"name\": \"Which switch brands are named on this product page?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Named brands include Cisco, Arista, NVIDIA Mellanox, Juniper, and Dell.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092800946260,"sku":"YY-QSFPDD-SR8-100M","price":1348.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/800g-qsfpdd-sr8.jpg?v=1793931426"},{"product_id":"800g-qsfp-dd-vr8-pam4-850nm-50m-dom-single-mpo-16-apc-multimode-optical-module","title":"YYGL 800G QSFP-DD VR8 850nm 50m MPO-16 Multimode Optical Transceiver","description":"\u003ch2\u003eYYGL 800G QSFP-DD VR8 Multimode Optical Transceiver | PAM4 | 850nm | 50m | Single MPO-16\/APC | DOM\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 800G QSFP-DD VR8\u003c\/strong\u003e transceiver delivers \u003cstrong\u003e800Gbps over 50 meters of OM4 multimode fiber\u003c\/strong\u003e in the compact QSFP-DD form factor. Optimized for ultra-short-reach intra-rack GPU interconnects and top-of-rack switch connections in AI training clusters and hyperscale data centers.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e800Gbps QSFP-DD:\u003c\/strong\u003e High-density form factor for maximum switch port utilization.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e50m OM4 Reach:\u003c\/strong\u003e Ideal for intra-rack and adjacent-rack short-reach deployments (30m on OM3).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSingle MPO-16\/APC:\u003c\/strong\u003e Simplified single-connector cabling for high-density environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePAM4 Modulation:\u003c\/strong\u003e 8×100G parallel channels for efficient MMF bandwidth use.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDOM Supported:\u003c\/strong\u003e Real-time optical power, temperature, and voltage monitoring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQSFP-DD MSA Compliant:\u003c\/strong\u003e Conforms to QSFP-DD MSA and CMIS Rev 5.2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; background-color: #f4f6f8; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; background-color: #f4f6f8; text-align: left;\"\u003eValue \/ Parameter\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eYY-QSFPDD-VR8-50M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e800Gbps (8×100Gbps PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eQSFP-DD 800\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Transmitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e8-Channel VCSEL Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003ePIN Photodetector Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eMultimode OM3\/OM4 (MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eMaximum Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e50m over OM4 \/ 30m over OM3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eSingle MPO-16\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e≤15W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e3.3V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e0°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eCMIS Rev 5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eStandards \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eQSFP-DD MSA, IEEE 802.3db\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eDigital Diagnostics (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eHost Coding Available For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eCisco, Arista, NVIDIA Mellanox, Juniper, Dell\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eCompliance Documents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eAvailable per SKU on request\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHost Coding \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003eEach module undergoes full burn-in and switch validation testing before shipment. Pre-coded for Cisco, Arista, NVIDIA Mellanox, Juniper, or Dell hosts.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat connector interface does 800G QSFP-DD VR8 use?\u003c\/h4\u003e\n\u003cp\u003eIt utilizes a single MPO-16\/APC connector for high port density cabling.\u003c\/p\u003e\n\u003ch4\u003eWhat is the transmission reach?\u003c\/h4\u003e\n\u003cp\u003eIt achieves up to 50 meters on OM4 multimode fiber and 30 meters on OM3.\u003c\/p\u003e\n\u003ch4\u003eWhat is the maximum power consumption?\u003c\/h4\u003e\n\u003cp\u003eMaximum power dissipation is rated at ≤15W.\u003c\/p\u003e\n\u003ch4\u003eIs it compatible with Arista and NVIDIA switches?\u003c\/h4\u003e\n\u003cp\u003eYes, custom EEPROM coding is verified on host hardware before dispatch.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eOrdering \u0026amp; RFQ Information\u003c\/h3\u003e\n\u003cp\u003eContact us for sample evaluation units and wholesale project volume pricing.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What connector interface does 800G QSFP-DD VR8 use?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It utilizes a single MPO-16\/APC connector for high port density cabling.\"}}, {\"@type\": \"Question\", \"name\": \"What is the transmission reach?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It achieves up to 50 meters on OM4 multimode fiber and 30 meters on OM3.\"}}, {\"@type\": \"Question\", \"name\": \"What is the maximum power consumption?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Maximum power dissipation is rated at ≤15W.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092800979028,"sku":"YY-QSFPDD-VR8-50M","price":1348.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/800g-qsfpdd-vr8.jpg?v=1793931428"},{"product_id":"400g-qsfp-dd-sr4-pam4-850nm-100m-dom-mpo-12-apc-multimode-optical-module","title":"YYGL 400G QSFP-DD SR4 850nm 100m MPO-12 Multimode Optical Transceiver","description":"\u003ch2\u003eYYGL 400G QSFP-DD SR4 Multimode Optical Transceiver | 850nm | 100m | MPO-12 | DOM\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 400G QSFP-DD SR4\u003c\/strong\u003e transceiver delivers \u003cstrong\u003e400Gbps over 100 meters of OM4 multimode fiber\u003c\/strong\u003e using 4×100G PAM4 parallel channels at 850nm. A cost-effective, high-density solution for data center leaf-spine fabric, AI cluster interconnects, and enterprise core switching upgrades.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e400Gbps in QSFP-DD:\u003c\/strong\u003e High port density for leaf-spine and core switching deployments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e100m OM4 Reach:\u003c\/strong\u003e Covers standard data center hall distances with existing MMF infrastructure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPO-12 Connector:\u003c\/strong\u003e Industry-standard interface compatible with pre-terminated fiber assemblies.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePAM4 Modulation:\u003c\/strong\u003e 4×100G parallel architecture for efficient multimode fiber use.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDOM Supported:\u003c\/strong\u003e Real-time monitoring of optical power, temperature, and voltage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQSFP-DD MSA Compliant:\u003c\/strong\u003e Conforms to QSFP-DD MSA and CMIS Rev 5.2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; background-color: #f4f6f8; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; background-color: #f4f6f8; text-align: left;\"\u003eValue \/ Parameter\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eYY-QSFPDD-SR4-100M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e400Gbps (4×100Gbps PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eQSFP-DD\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Transmitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e4-Channel VCSEL Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003ePIN Photodetector Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eMultimode Fiber (OM3 \/ OM4 MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eMaximum Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e100m over OM4 \/ 60m over OM3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eMPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e≤8W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e3.3V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e0°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eCMIS Rev 5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eStandards \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eQSFP-DD MSA, IEEE 802.3db\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eDigital Diagnostics (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eHost Coding Available For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eCisco, Arista, NVIDIA Mellanox, Juniper, Dell\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eCompliance Documents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eAvailable per SKU on request\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHost Coding \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003ePre-coded and tested on OEM host switches including Cisco Nexus, Arista, NVIDIA Mellanox, and Juniper platforms.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is the power consumption of 400G QSFP-DD SR4?\u003c\/h4\u003e\n\u003cp\u003eThe module features an ultra-low power design of ≤8W, preventing thermal throttling.\u003c\/p\u003e\n\u003ch4\u003eWhich fiber and connector are required?\u003c\/h4\u003e\n\u003cp\u003eIt uses MPO-12\/APC connectors over OM3\/OM4 multimode fiber (up to 100m on OM4).\u003c\/p\u003e\n\u003ch4\u003eCan this module breakout to 4x100G?\u003c\/h4\u003e\n\u003cp\u003eYes, it supports breakout configurations to 4x 100G SR links on compatible switch ports.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eOrdering \u0026amp; RFQ Information\u003c\/h3\u003e\n\u003cp\u003eSubmit an RFQ for engineering evaluation samples and tiered volume pricing.\u003c\/p\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092801011796,"sku":"YY-QSFPDD-SR4-100M","price":272.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/400g-qsfp-dd-sr4-1.png?v=1795224801"},{"product_id":"400g-qsfp-dd-fr4-pam4-1310nm-2km-dom-lc-duplex-single-mode-optical-module","title":"YYGL 400G QSFP-DD FR4 1310nm 2km LC Duplex Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL 400G QSFP-DD FR4 Single-Mode Optical Transceiver | PAM4 | 1310nm | 2km | LC Duplex | DOM\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 400G QSFP-DD FR4\u003c\/strong\u003e transceiver delivers 400Gbps over 2km of OS2 single-mode fiber (SMF) using 4-wavelength CWDM4 technology over standard LC duplex connectors. Engineered for data center interconnect (DCI), campus backbones, and enterprise core networks requiring extended SMF reach without replacing duplex fiber cabling infrastructure.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e2km Extended Single-Mode Reach:\u003c\/strong\u003e Delivers 400Gbps over standard duplex SMF, ideal for campus-scale backbone links and inter-building DCI.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCWDM4 Multiplexing Efficiency:\u003c\/strong\u003e Multiplexes 4×100G optical lanes onto a single duplex fiber pair, significantly saving optical cabling costs compared to parallel MPO solutions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal LC Duplex Interface:\u003c\/strong\u003e Directly compatible with existing LC patch panels and structured telecom fiber plant.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHost Coding:\u003c\/strong\u003e Coding available for Cisco, Arista, NVIDIA Mellanox, Juniper, or Dell switches; we check coding for your switch model before you order.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDigital Optical Monitoring (DOM):\u003c\/strong\u003e Comprehensive real-time monitoring of operating temperature, supply voltage, laser bias current, and TX\/RX optical power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width: 35%;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"width: 65%;\"\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \u0026amp; Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e400G QSFP-DD FR4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e400Gbps (4×100G PAM4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eQSFP-DD Type 2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWavelength Grid\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCWDM4 (1271nm, 1291nm, 1311nm, 1331nm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSingle-Mode Fiber (SMF, OS2 \/ G.652)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2km\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard LC Duplex\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModulation Scheme\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4×100G-PAM4 CWDM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e≤10W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.3V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransmitter \u0026amp; Detector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCWDM EML Transmitter \u0026amp; PIN Receiver\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCMIS 4.0 \/ CMIS 5.0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0°C ~ 70°C (32°F ~ 158°F) Commercial Grade\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eQSFP-DD MSA, 100G Lambda MSA 400G-FR4, IEEE 802.3bs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSupported\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCoding Available For\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCisco, Arista, NVIDIA Mellanox, Juniper, Dell\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e400G Single-Mode Architecture Comparison\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse; margin-top: 10px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f7f7f7;\"\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n      \u003cth\u003e400G QSFP-DD FR4 (This Model)\u003c\/th\u003e\n      \u003cth\u003e400G QSFP-DD DR4\u003c\/th\u003e\n      \u003cth\u003e400G QSFP-DD LR4\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2km\u003c\/td\u003e\n      \u003ctd\u003e500m\u003c\/td\u003e\n      \u003ctd\u003e10km\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFiber Connector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLC Duplex (2 Fibers)\u003c\/td\u003e\n      \u003ctd\u003eMPO-12\/APC (8 Active Fibers)\u003c\/td\u003e\n      \u003ctd\u003eLC Duplex (2 Fibers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOptical Multiplexing\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCWDM4 (Wavelength Mux)\u003c\/td\u003e\n      \u003ctd\u003eParallel Single-Mode (PSM4)\u003c\/td\u003e\n      \u003ctd\u003eLWDM4 \/ LAN-WDM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFiber Infrastructure Cost\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLow (Reuses existing 2-fiber LC plant)\u003c\/td\u003e\n      \u003ctd\u003eRequires parallel MPO-12 trunking\u003c\/td\u003e\n      \u003ctd\u003eLow (Reuses existing 2-fiber LC plant)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTarget Application\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCampus Backbone \u0026amp; Inter-building DCI\u003c\/td\u003e\n      \u003ctd\u003eIntra-Building Spine-Leaf \u0026amp; Breakout\u003c\/td\u003e\n      \u003ctd\u003eMetro Edge \u0026amp; Telecom Core\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eQuality Assurance \u0026amp; Testing\u003c\/h3\u003e\n\u003cp\u003eEach module is tested before dispatch. Our test process includes 3D end-face interferometry, optical eye-diagram checks, bit error rate checks, and switch port link testing. Ask us for test records for this SKU. Engineering support is available when you inquire.\u003c\/p\u003e\n\n\u003ch3\u003eCustom Coding \u0026amp; Sample Inquiries\u003c\/h3\u003e\n\u003cp\u003eWe provide custom EEPROM coding for Cisco, Arista, NVIDIA Mellanox, Juniper, or Dell hosts. Compatibility depends on the host platform. Please share your switch model, software version, module type, link distance and fiber type so we can check coding and compatibility before you order. YYGL Optical is an independent optics supplier; we are not those brands and we do not claim affiliation with them. For volume pricing, project sample requests, or custom cabling configurations, please submit an inquiry or contact our engineering sales team.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions \u0026amp; Interoperability\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does YYGL Optical ensure 400G QSFP-DD transceiver compatibility with Cisco Nexus 9000 and Arista switches?\u003c\/strong\u003e\u003cbr\u003e\nA: YYGL Optical programs custom EEPROM vendor coding into each 400G QSFP-DD module to ensure non-alarm recognition on Cisco Nexus 9300\/9400 series (supporting service unsupported-transceiver bypass when required) and Arista EOS hosts. Built with high-reliability COB packaging, our 400G modules deliver lower thermal resistance and typical power consumption under 10W.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does YYGL Optical support custom EEPROM programming for mixed-vendor data center architectures?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes. Because modern hyperscale fabrics frequently deploy mixed switch platforms, our engineering team offers bespoke firmware flashing for multi-vendor environments, allowing seamless link establishment across disparate spine-leaf tiers.\u003c\/p\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092801044564,"sku":"YY-QSFPDD-FR4-2KM","price":341.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/400g-fr4-qsfpdd.jpg?v=1793931406"},{"product_id":"400g-qsfp-dd-dr4-pam4-1310nm-500m-dom-mpo-12-apc-single-mode-optical-module","title":"YYGL 400G QSFP-DD DR4 1310nm 500m MPO-12 Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL 400G QSFP-DD DR4 Single-Mode Optical Transceiver | PAM4 | 1310nm | 500m | MPO-12\/APC | DOM\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 400G QSFP-DD DR4\u003c\/strong\u003e transceiver delivers 400Gbps over 500 meters of OS2 single-mode fiber (SMF) using 4×100G PAM4 parallel optical channels at 1310nm with an MPO-12\/APC interface. Ideal for AI computing clusters, high-density spine-leaf fabrics, campus data center interconnects (DCI), and 400G-to-4x100G breakout connections.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Throughput Parallel SMF:\u003c\/strong\u003e 400Gbps aggregate bandwidth powered by 4×100G PAM4 parallel architecture, bridging short-reach multimode and long-reach CWDM applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersatile Breakout Capability:\u003c\/strong\u003e Supports direct 400G-to-400G links or 400G-to-4×100G DR1\/FR1 breakout cabling to optimize port density.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHost Coding:\u003c\/strong\u003e Coding available for Cisco, Arista, NVIDIA Mellanox, Juniper, or Dell switches and routers; we check coding for your switch model before you order.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDigital Optical Monitoring (DOM):\u003c\/strong\u003e Comprehensive real-time monitoring of operating temperature, supply voltage, laser bias current, and TX\/RX optical power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width: 35%;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"width: 65%;\"\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \u0026amp; Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e400G QSFP-DD DR4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e400Gbps (4×100G PAM4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eQSFP-DD Type 2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1310nm Parallel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSingle-Mode Fiber (SMF, OS2 \/ G.652)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500m\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMPO-12\/APC (MTP-12 APC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModulation Scheme\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4×100G-PAM4 (Electrical \u0026amp; Optical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e≤10W (Typical low-power thermal design)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.3V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransmitter \u0026amp; Detector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEML \/ SiPh Transmitter \u0026amp; PIN Receiver\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCMIS 4.0 \/ CMIS 5.0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0°C ~ 70°C (32°F ~ 158°F) Commercial Grade\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eQSFP-DD MSA, IEEE 802.3bs 400GBASE-DR4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSupported\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCoding Available For\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCisco, Arista, NVIDIA Mellanox, Juniper, Dell\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e400G Single-Mode vs Multimode Architecture Comparison\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse; margin-top: 10px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f7f7f7;\"\u003e\n      \u003cth\u003eFeature\u003c\/th\u003e\n      \u003cth\u003e400G QSFP-DD DR4 (This Model)\u003c\/th\u003e\n      \u003cth\u003e400G QSFP-DD FR4\u003c\/th\u003e\n      \u003cth\u003e400G QSFP-DD SR4\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax Distance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500m\u003c\/td\u003e\n      \u003ctd\u003e2km\u003c\/td\u003e\n      \u003ctd\u003e100m (OM4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOptical Medium\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSingle-Mode (SMF)\u003c\/td\u003e\n      \u003ctd\u003eSingle-Mode (SMF)\u003c\/td\u003e\n      \u003ctd\u003eMultimode (MMF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOptical Scheme\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4×100G Parallel (1310nm)\u003c\/td\u003e\n      \u003ctd\u003eCWDM4 Multiplexing (1271-1331nm)\u003c\/td\u003e\n      \u003ctd\u003e4×100G Parallel (850nm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n      \u003ctd\u003eLC Duplex\u003c\/td\u003e\n      \u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBreakout Support\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eYes (4×100G DR1\/FR1)\u003c\/td\u003e\n      \u003ctd\u003eNo (WDM Multiplexed)\u003c\/td\u003e\n      \u003ctd\u003eYes (4×100G SR1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePrimary Application\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSpine-Leaf \u0026amp; High-Density Breakout\u003c\/td\u003e\n      \u003ctd\u003eLonger Campus DCI Backbone\u003c\/td\u003e\n      \u003ctd\u003eIntra-Rack Server-to-TOR\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eQuality Assurance \u0026amp; Testing\u003c\/h3\u003e\n\u003cp\u003eEach module is tested before dispatch. Our test process includes 3D end-face interferometry, optical eye-diagram checks, bit error rate checks, and switch port link testing. Ask us for test records for this SKU. Engineering support is available when you inquire.\u003c\/p\u003e\n\n\u003ch3\u003eCustom Coding \u0026amp; Sample Inquiries\u003c\/h3\u003e\n\u003cp\u003eWe provide custom EEPROM coding for Cisco, Arista, NVIDIA Mellanox, Juniper, or Dell hosts. Compatibility depends on the host platform. Please share your switch model, software version, module type, link distance and fiber type so we can check coding and compatibility before you order. YYGL Optical is an independent optics supplier; we are not those brands and we do not claim affiliation with them. For volume pricing, project sample requests, or custom cabling configurations, please submit an inquiry or contact our engineering sales team.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions \u0026amp; Interoperability\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does YYGL Optical ensure 400G QSFP-DD transceiver compatibility with Cisco Nexus 9000 and Arista switches?\u003c\/strong\u003e\u003cbr\u003e\nA: YYGL Optical programs custom EEPROM vendor coding into each 400G QSFP-DD module to ensure non-alarm recognition on Cisco Nexus 9300\/9400 series (supporting service unsupported-transceiver bypass when required) and Arista EOS hosts. Built with high-reliability COB packaging, our 400G modules deliver lower thermal resistance and typical power consumption under 10W.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does YYGL Optical support custom EEPROM programming for mixed-vendor data center architectures?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes. Because modern hyperscale fabrics frequently deploy mixed switch platforms, our engineering team offers bespoke firmware flashing for multi-vendor environments, allowing seamless link establishment across disparate spine-leaf tiers.\u003c\/p\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092801077332,"sku":"YY-QSFPDD-DR4-500M","price":314.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/400g-dr4-qsfpdd.jpg?v=1793931403"},{"product_id":"400g-osfp-sr8-pam4-850nm-100m-dom-dual-mpo-12-apc-multimode-optical-module","title":"YYGL 400G OSFP SR8 850nm 100m MPO-16 Multimode Optical Transceiver","description":"\u003ch2\u003e400G OSFP SR8 Multimode Optical Module | PAM4 | 850nm | 100m | DOM | Single MPO-16\/APC\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 400G OSFP SR8\u003c\/strong\u003e optical module is purpose-built for hyperscale data centers and high-density AI computing clusters. Utilizing PAM4 modulation with an \u003cstrong\u003e8×50G\u003c\/strong\u003e parallel channel architecture, it supports a maximum transmission distance of \u003cstrong\u003e100 meters\u003c\/strong\u003e over OM4 multimode fiber.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Bandwidth:\u003c\/strong\u003e 400Gbps aggregate bandwidth via 8×50G PAM4 parallel channels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePAM4 Modulation:\u003c\/strong\u003e Efficient multimode fiber utilization with low latency.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDigital Optical Monitoring (DOM):\u003c\/strong\u003e Real-time telemetry for laser bias, temperature, and power.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e850nm Wavelength:\u003c\/strong\u003e Compatible with OM3\/OM4 multimode fiber infrastructure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSingle MPO-16\/APC Interface:\u003c\/strong\u003e High-density parallel optical connectivity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Consumes ≤9W for optimal rack thermal management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; background-color: #f4f6f8; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; background-color: #f4f6f8; text-align: left;\"\u003eValue \/ Parameter\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eYY-OSFP-SR8-100M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e400Gbps (8×50Gbps PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eOSFP\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Transmitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e8-Channel VCSEL Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003ePIN Photodetector Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eMultimode OM3\/OM4 (MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eMaximum Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e100m over OM4 \/ 70m over OM3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eSingle MPO-16\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e≤9W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e3.3V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e0°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eCMIS Rev 5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eStandards \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eOSFP MSA, IEEE 802.3db\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eDigital Diagnostics (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eHost Coding Available For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eCisco, Arista, NVIDIA Mellanox, Juniper, Dell\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eCompliance Documents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eAvailable per SKU on request\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHost Coding \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003eEach module is tested on host hardware prior to dispatch. Pre-coded for Cisco, Arista, NVIDIA Mellanox, Juniper, and Dell switches.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is the difference between OSFP SR8 and QSFP-DD SR4?\u003c\/h4\u003e\n\u003cp\u003eOSFP SR8 uses an 8x50G electrical and optical architecture with MPO-16, whereas SR4 uses 4x100G with MPO-12.\u003c\/p\u003e\n\u003ch4\u003eWhat is the typical power consumption?\u003c\/h4\u003e\n\u003cp\u003ePower consumption is exceptionally low at ≤9W.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eOrdering \u0026amp; RFQ Information\u003c\/h3\u003e\n\u003cp\u003eContact YYGL Optical for wholesale pricing, sample requests, and technical datasheets.\u003c\/p\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092801110100,"sku":"YY-OSFP-SR8-400G-100M","price":369.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/1_799ac29d-976c-4c77-b421-b79b75750ed7.jpg?v=1781763124"},{"product_id":"400g-qsfp-dd-sr4-plus-pam4-850nm-mma4z00-ns400-dom-mpo-multimode-optical-module","title":"YYGL 400G QSFP-DD SR4+ 850nm 100m MPO-12 Multimode Optical Transceiver","description":"\u003ch2\u003e400G QSFP-DD SR4+ Multimode Optical Module | PAM4 | 850nm | DOM | MPO | MMA4Z00-NS400 Compatible\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 400G QSFP-DD SR4+\u003c\/strong\u003e optical module is an enhanced short-reach multimode solution designed for hyperscale data centers and AI computing clusters. Compatible with the \u003cstrong\u003eMMA4Z00-NS400\u003c\/strong\u003e specification, it delivers \u003cstrong\u003e400Gbps\u003c\/strong\u003e aggregate bandwidth via PAM4 modulation over OM4 multimode fiber.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Short-Reach Performance:\u003c\/strong\u003e Extended reach over OM4 multimode fiber compared to standard SR4.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePAM4 Modulation:\u003c\/strong\u003e 4×100G PAM4 parallel architecture for efficient fiber utilization.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMMA4Z00-NS400 Compatible:\u003c\/strong\u003e Pre-coded for seamless plug-and-play in NVIDIA Mellanox environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDigital Optical Monitoring (DOM):\u003c\/strong\u003e Real-time monitoring of temperature, voltage, and optical power.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPO-12 Interface:\u003c\/strong\u003e Standard parallel fiber interface for high-density cabling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Consumes ≤8.5W.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; background-color: #f4f6f8; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; background-color: #f4f6f8; text-align: left;\"\u003eValue \/ Parameter\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eYY-QSFPDD-SR4PLUS-100M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e400Gbps (4×100Gbps PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eQSFP-DD\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Transmitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eVCSEL Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003ePIN Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eMultimode OM3\/OM4 (MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eMaximum Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e100m over OM4\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eMPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e≤8.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e0°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eStandards \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eQSFP-DD MSA, CMIS Rev 5.2, MMA4Z00-NS400 Compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eDigital Diagnostics (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eHost Coding Available For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eNVIDIA Mellanox, Cisco, Arista, Juniper, Dell\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eCompliance Documents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eAvailable per SKU on request\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHost Coding \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003eSpecifically verified for NVIDIA Mellanox Quantum \/ Spectrum series switches as an alternative to MMA4Z00-NS400.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eIs this transceiver a compatible replacement for NVIDIA MMA4Z00-NS400?\u003c\/h4\u003e\n\u003cp\u003eYes, it is fully tested and pre-coded to operate seamlessly in NVIDIA Mellanox switch environments without error warnings.\u003c\/p\u003e\n\u003ch4\u003eWhat fiber connector does it use?\u003c\/h4\u003e\n\u003cp\u003eIt uses standard MPO-12\/APC multimode optical connectors.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eOrdering \u0026amp; RFQ Information\u003c\/h3\u003e\n\u003cp\u003eContact our technical sales team for wholesale pricing, compatibility confirmation, and sample orders.\u003c\/p\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092801142868,"sku":"YY-QSFPDD-SR4P-100M","price":314.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/400g-sr4-plus-qsfpdd.jpg?v=1793931408"},{"product_id":"10g-sfp-plus-sr-850nm-300m-dom-lc-duplex-multimode-optical-module-transceiver","title":"YYGL 10G SFP+ SR 850nm 300m LC Duplex Multimode Optical Transceiver","description":"\u003ch2\u003e10G SFP+ SR Multimode Optical Module | 850nm | 300m | DOM | LC Duplex\u003c\/h2\u003e\u003cp\u003eThe YYGL 10G SFP+ SR optical module is designed for short-reach multimode fiber transmission in enterprise data centers and campus networks. Operating at \u003cstrong\u003e850nm\u003c\/strong\u003e wavelength with LC Duplex interface, it supports a maximum transmission distance of \u003cstrong\u003e300 meters\u003c\/strong\u003e over OM3 multimode fiber — the ideal choice for intra-rack and inter-rack 10G connections.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e850nm VCSEL Laser:\u003c\/strong\u003e Optimized for OM3\/OM4 multimode fiber, delivering reliable short-reach 10G connectivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Optical Monitoring (DOM):\u003c\/strong\u003e Real-time monitoring of temperature, voltage, bias current, and TX\/RX optical power for simplified network operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLC Duplex Interface:\u003c\/strong\u003e Standard LC duplex connector for SFP+ ports on switches, routers, and servers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Designed to SFP+ MSA and IEEE 802.3ae specifications; coded for the host you name\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Operating Temperature Range:\u003c\/strong\u003e 0°C ~ 70°C commercial-grade temperature range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance Documents:\u003c\/strong\u003e Available per SKU on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003e10.3125 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eSFP+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e850nm (TX\/RX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Type\u003c\/td\u003e\n\u003ctd\u003eMultimode OM3\/OM4 (MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Distance\u003c\/td\u003e\n\u003ctd\u003e300m (OM3) \/ 400m (OM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eLC Duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Diagnostics\u003c\/td\u003e\n\u003ctd\u003eDOM Supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd\u003e1.0W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C ~ 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eSFP+ MSA, IEEE 802.3ae\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eWidely deployed in enterprise data center top-of-rack (ToR) interconnects, campus network aggregation, storage area networks (SAN), and 10G server connections.\u003c\/p\u003e\u003cp\u003eCoding is available for Cisco, Arista, NVIDIA Mellanox, Juniper, or Dell hosts. Compatibility depends on the host platform. Please share your switch model, software version, module type, link distance and fiber type so we can check coding and compatibility before you order. Each module is tested before it ships. YYGL Optical is an independent optics supplier; we are not those brands and we do not claim affiliation with them. Contact us for product selection assistance.\u003c\/p\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092801175636,"sku":"YY-SFP-SR-300M","price":9.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/10g-sfp-sr.jpg?v=1793931397"},{"product_id":"10g-sfp-plus-lr-1310nm-10km-dom-lc-duplex-single-mode-optical-module-transceiver","title":"YYGL 10G SFP+ LR 1310nm 10km LC Duplex Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 10G SFP+ LR 1310nm 10km LC Duplex Single-Mode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 10G SFP+ LR\u003c\/strong\u003e is an enterprise-grade 10Gbps single-mode optical transceiver engineered for robust long-reach campus networks, data center inter-rack connections, and metropolitan area network (MAN) aggregation. Operating at the standard 1310nm optical transmission window over G.652 single-mode fiber (SMF), it provides reliable transmission up to \u003cstrong\u003e10 kilometers\u003c\/strong\u003e via standard LC Duplex connectors with full digital optical monitoring (DOM) and ultra-low power consumption under 1.0W.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProven 1310nm DFB Laser Technology:\u003c\/strong\u003e Equipped with an uncooled, high-stability 1310nm Distributed Feedback (DFB) laser and high-sensitivity PIN photodetector for error-free transmission up to 10km.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUltra-Low Power Consumption:\u003c\/strong\u003e Maximum power dissipation is strictly ≤1.0W, drastically reducing thermal loads in high-density 24-port and 48-port SFP+ switch line cards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive SFF-8472 DOM Telemetry:\u003c\/strong\u003e Real-time digital diagnostics monitoring (DOM\/DDM) over I2C, tracking internal temperature, supply voltage, Tx bias current, Tx output power, and Rx received optical power.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal SFP+ Compatibility:\u003c\/strong\u003e Built in accordance with SFP+ MSA (SFF-8431) and IEEE 802.3ae 10GBASE-LR standards, ensuring hot-pluggable reliability across enterprise platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-SFP-LR-10KM\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125Gbps (10GBASE-LR) \/ 9.953Gbps (10GBASE-LW)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFP+ (Enhanced Small Form-Factor Pluggable)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1310nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode Fiber (OS2 \/ G.652 SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Transmission Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kilometers (6.2 miles)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC Duplex (UPC polish)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter \/ Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1310nm DFB Laser \/ PIN Receiver\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1.0W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFF-8431, SFF-8472, IEEE 802.3ae, RoHS-6, CE, Class 1 Laser\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (SFF-8472 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Bench Testing\u003c\/h3\u003e\n\u003cp\u003eEach YYGL Optical 10G SFP+ LR module is individually programmed and tested on OEM switch hardware before shipment. Pre-coded EEPROM configurations are available for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco:\u003c\/strong\u003e Catalyst 3850\/9300, Nexus 3000\/9000, and ASR series.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista Networks:\u003c\/strong\u003e 7050, 7150, and 7280 series switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper Networks:\u003c\/strong\u003e EX and QFX series Ethernet switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell Technologies:\u003c\/strong\u003e Networking N-Series and S-Series switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMikroTik \/ Ubiquiti:\u003c\/strong\u003e CCR, CRS, and EdgeSwitch enterprise routers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTarget Application Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCampus Backbone Links:\u003c\/strong\u003e Interconnecting core and aggregation switches across campus buildings spanning up to 10km.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eData Center Aggregation:\u003c\/strong\u003e Reliable 10G server uplinks and inter-rack connectivity where distances exceed standard multimode SR limits (300m).\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is the difference between 10G SFP+ SR and 10G SFP+ LR?\u003c\/h4\u003e\n\u003cp\u003eSR (Short Reach) operates at 850nm over multimode fiber (MMF) up to 300 meters, whereas LR (Long Reach) operates at 1310nm over single-mode fiber (SMF) up to 10 kilometers. LR is required whenever link distances exceed 300m or when connecting over single-mode campus infrastructure.\u003c\/p\u003e\n\n\u003ch4\u003eWhat optical patch cord is required for 10G LR?\u003c\/h4\u003e\n\u003cp\u003eA standard 9\/125µm single-mode duplex fiber cable (OS2) with blue LC-to-LC connectors (UPC polish) is required.\u003c\/p\u003e\n\n\u003ch4\u003eCan this 10G LR module be used on a 1km link without attenuators?\u003c\/h4\u003e\n\u003cp\u003eYes. The receiver sensitivity and maximum input power range allow direct operation from 2 meters up to 10km without the risk of receiver saturation or need for optical attenuators.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Evaluation \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eWe welcome lab evaluation requests and bulk enterprise orders. Contact YYGL Optical technical sales for coding verification, datasheets, and quantity discounts.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is the difference between 10G SFP+ SR and 10G SFP+ LR?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"SR (Short Reach) operates at 850nm over multimode fiber (MMF) up to 300 meters, whereas LR (Long Reach) operates at 1310nm over single-mode fiber (SMF) up to 10 kilometers. LR is required whenever link distances exceed 300m or when connecting over single-mode campus infrastructure.\"}},{\"@type\":\"Question\",\"name\":\"What optical patch cord is required for 10G LR?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A standard 9\/125µm single-mode duplex fiber cable (OS2) with blue LC-to-LC connectors (UPC polish) is required.\"}},{\"@type\":\"Question\",\"name\":\"Can this 10G LR module be used on a 1km link without attenuators?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. The receiver sensitivity and maximum input power range allow direct operation from 2 meters up to 10km without the risk of receiver saturation or need for optical attenuators.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092801208404,"sku":"YY-SFP-LR-10KM","price":9.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/1_37686148-49ac-45e2-865d-2eed49bcf8f7.jpg?v=1782446555"},{"product_id":"10g-sfp-plus-er-1550nm-40km-dom-lc-duplex-single-mode-optical-module-transceiver","title":"YYGL 10G SFP+ ER 1550nm 40km LC Duplex Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 10G SFP+ ER 1550nm 40km LC Duplex Single-Mode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 10G SFP+ ER\u003c\/strong\u003e is a high-performance extended-reach single-mode optical transceiver designed for metropolitan area networks (MAN), regional campus backbones, and data center interconnects (DCI). Operating at the low-attenuation 1550nm optical window over single-mode fiber (SMF), it provides reliable transmission up to \u003cstrong\u003e40 kilometers\u003c\/strong\u003e via standard LC Duplex connectors without needing optical amplifiers.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1550nm Cooled EML Laser:\u003c\/strong\u003e Utilizes an electro-absorption modulated laser (EML) operating at 1550nm where fiber attenuation is minimized (~0.2dB\/km), delivering high dispersion tolerance over 40km links.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Power Link Budget:\u003c\/strong\u003e Designed with an optical power budget exceeding 15dB, ensuring dependable signal integrity across mid-range regional fiber spans.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive SFF-8472 DOM Telemetry:\u003c\/strong\u003e Built-in digital diagnostics provide active monitoring of module temperature, supply voltage, laser bias, and Tx\/Rx optical power levels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnergy Efficient Operation:\u003c\/strong\u003e Total power dissipation strictly controlled at ≤1.5W, compatible with commercial temperature environments (0°C to 70°C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-SFP-ER-40KM\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125Gbps (10GBASE-ER)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFP+ (Enhanced Small Form-Factor Pluggable)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1550nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode Fiber (OS2 \/ G.652 SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Transmission Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kilometers (24.8 miles)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC Duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter \/ Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1550nm Cooled EML Laser \/ High-Sensitivity PIN Receiver\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFF-8431, SFF-8472, IEEE 802.3ae 10GBASE-ER, RoHS-6, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (SFF-8472 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Lab Validation\u003c\/h3\u003e\n\u003cp\u003eEach module is verified on live switch test beds for bit error rate performance (BER \u0026lt; 1E-12). Pre-coded EEPROM configurations are available for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco:\u003c\/strong\u003e Catalyst, Nexus, and ASR router series.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista Networks:\u003c\/strong\u003e 7050, 7150, and 7280 series.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper Networks:\u003c\/strong\u003e MX and QFX platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell Technologies:\u003c\/strong\u003e PowerSwitch enterprise series.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMikroTik \/ Ubiquiti:\u003c\/strong\u003e Carrier-grade routing platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTarget Application Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMetropolitan Area Networks (MAN):\u003c\/strong\u003e Direct interconnects between enterprise offices or colocation facilities spanning 10km to 40km without optical repeaters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMid-Range DCI:\u003c\/strong\u003e Data center replication and backup transport links across regional campuses.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eHow does 10G SFP+ ER differ from 10G SFP+ LR?\u003c\/h4\u003e\n\u003cp\u003eWhile 10G LR uses a 1310nm laser for distances up to 10km, 10G ER utilizes a cooled 1550nm EML laser capable of bridging up to 40km over standard single-mode fiber, making ER suitable for inter-city and metro-scale networking.\u003c\/p\u003e\n\n\u003ch4\u003eDo I need an optical attenuator when testing 10G ER on short links in a lab?\u003c\/h4\u003e\n\u003cp\u003eYes. Because the 10G ER transmitter outputs significant optical power, testing it back-to-back on a short fiber patch cable (e.g., \u0026lt;10km) requires a 5dB to 10dB optical attenuator to prevent overloading or damaging the optical receiver.\u003c\/p\u003e\n\n\u003ch4\u003eIs digital diagnostics monitoring (DOM) supported?\u003c\/h4\u003e\n\u003cp\u003eYes. Full SFF-8472 compliant DOM telemetry is built into the module, allowing continuous monitoring of laser bias, internal temperature, voltage, and optical power.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Evaluation \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eContact YYGL Optical to request sample units, verify switch hardware compatibility, or discuss bulk pricing for network infrastructure rollouts.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"How does 10G SFP+ ER differ from 10G SFP+ LR?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"While 10G LR uses a 1310nm laser for distances up to 10km, 10G ER utilizes a cooled 1550nm EML laser capable of bridging up to 40km over standard single-mode fiber, making ER suitable for inter-city and metro-scale networking.\"}},{\"@type\":\"Question\",\"name\":\"Do I need an optical attenuator when testing 10G ER on short links in a lab?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Because the 10G ER transmitter outputs significant optical power, testing it back-to-back on a short fiber patch cable (e.g., \u003c10km) requires a 5dB to 10dB optical attenuator to prevent overloading or damaging the optical receiver.\"}},{\"@type\":\"Question\",\"name\":\"Is digital diagnostics monitoring (DOM) supported?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Full SFF-8472 compliant DOM telemetry is built into the module, allowing continuous monitoring of laser bias, internal temperature, voltage, and optical power.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092801241172,"sku":"YY-SFP-ER-40KM","price":11.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/10g-sfp-er.jpg?v=1793931399"},{"product_id":"10g-sfp-plus-zr-1550nm-80km-dom-lc-duplex-single-mode-optical-module-transceiver","title":"YYGL 10G SFP+ ZR 1550nm 80km LC Duplex Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 10G SFP+ ZR 1550nm 80km LC Duplex Single-Mode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 10G SFP+ ZR\u003c\/strong\u003e is an ultra-long-reach single-mode optical transceiver engineered for telecom core backbones, cross-city regional networks, and long-distance data center interconnects (DCI). Operating at 1550nm over standard single-mode fiber (SMF), it achieves up to \u003cstrong\u003e80 kilometers\u003c\/strong\u003e transmission reach without in-line optical amplification, powered by a high-stability cooled EML laser and high-sensitivity APD receiver.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUltra-Long 80km Reach:\u003c\/strong\u003e High optical link budget (≥23dB) enables 80km point-to-point transmission over standard G.652 single-mode fiber, eliminating costly optical repeaters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Sensitivity APD Optical Receiver:\u003c\/strong\u003e Integrated Avalanche Photodiode (APD) receiver provides exceptional optical sensitivity (-24dBm), ensuring low bit error rates across long spans.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1550nm Cooled EML Transmitter:\u003c\/strong\u003e Advanced electro-absorption modulated laser (EML) with precision temperature control offers excellent chromatic dispersion tolerance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStrict Power Dissipation:\u003c\/strong\u003e Maximum power consumption is held at ≤1.5W, maintaining cool switch operation across commercial temperature ranges (0°C to 70°C).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSFF-8472 DOM Diagnostics:\u003c\/strong\u003e Real-time digital optical monitoring tracks module temperature, supply voltage, laser bias, Tx optical power, and Rx optical power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-SFP-ZR-80KM\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125Gbps (10GBASE-ZR)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFP+ (Enhanced Small Form-Factor Pluggable)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1550nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode Fiber (OS2 \/ G.652 SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Transmission Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kilometers (49.7 miles)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC Duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter \/ Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1550nm Cooled EML Laser \/ High-Sensitivity APD Receiver\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Link Budget\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥23 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFF-8431, SFF-8472, IEEE 802.3ae 10GBASE-ZR, RoHS-6, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (SFF-8472 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Lab Validation\u003c\/h3\u003e\n\u003cp\u003eEach module is verified on live switch test beds for bit error rate performance (BER \u0026lt; 1E-12). Pre-coded EEPROM configurations are available for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco:\u003c\/strong\u003e Catalyst, Nexus, and ASR router platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista Networks:\u003c\/strong\u003e 7050, 7150, and 7280 series.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper Networks:\u003c\/strong\u003e MX and QFX platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell Technologies:\u003c\/strong\u003e PowerSwitch enterprise series.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMikroTik \/ Ubiquiti:\u003c\/strong\u003e Carrier-grade routing platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTarget Application Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTelecom Backbone \u0026amp; WAN:\u003c\/strong\u003e Ultra-long distance regional transport connecting metropolitan points of presence (PoPs) up to 80km.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDisaster Recovery DCI:\u003c\/strong\u003e Synchronous or asynchronous data replication across geographically dispersed enterprise data centers.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is the difference between 10G SFP+ ER and 10G SFP+ ZR?\u003c\/h4\u003e\n\u003cp\u003e10G ER is rated for up to 40km reach using a standard PIN receiver, whereas 10G ZR is rated for up to 80km reach by combining a cooled EML laser with an Avalanche Photodiode (APD) receiver for superior optical sensitivity and link budget (≥23dB).\u003c\/p\u003e\n\n\u003ch4\u003eDo I need optical attenuators when testing 10G ZR on short fiber spans?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eYes, absolutely.\u003c\/strong\u003e An APD receiver can be permanently damaged by high optical input power. When testing in a laboratory or over links shorter than 20km, you MUST insert a 10dB to 15dB optical attenuator between the transmitter and receiver.\u003c\/p\u003e\n\n\u003ch4\u003eWhat optical patch cord is required?\u003c\/h4\u003e\n\u003cp\u003eUse a standard OS2 9\/125µm single-mode duplex fiber cable with LC Duplex connectors (UPC polish).\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Evaluation \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eContact YYGL Optical to request sample units, verify switch hardware compatibility, or discuss bulk pricing for carrier and enterprise network infrastructure.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is the difference between 10G SFP+ ER and 10G SFP+ ZR?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"10G ER is rated for up to 40km reach using a standard PIN receiver, whereas 10G ZR is rated for up to 80km reach by combining a cooled EML laser with an Avalanche Photodiode (APD) receiver for superior optical sensitivity and link budget (≥23dB).\"}},{\"@type\":\"Question\",\"name\":\"Do I need optical attenuators when testing 10G ZR on short fiber spans?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes, absolutely. An APD receiver can be permanently damaged by high optical input power. When testing in a laboratory or over links shorter than 20km, you MUST insert a 10dB to 15dB optical attenuator between the transmitter and receiver.\"}},{\"@type\":\"Question\",\"name\":\"What optical patch cord is required?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Use a standard OS2 9\/125µm single-mode duplex fiber cable with LC Duplex connectors (UPC polish).\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092801273940,"sku":"YY-SFP-ZR-80KM","price":8.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/10g-sfp-zr.jpg?v=1793931401"},{"product_id":"yiyuan-800g-osfp-dr8-1310nm-500m-mpo-12-single-mode-optical-transceiver","title":"YYGL 800G OSFP DR8 1310nm 500m MPO-12 Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL 800G OSFP DR8 1310nm 500m MPO-12 Single-Mode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 800G OSFP DR8\u003c\/strong\u003e is an 800G OSFP single-mode optical transceiver operating at 1310nm, supporting transmission distances of up to 500m over single-mode fiber (SMF) with a Dual MPO-12\/APC connector. Purpose-built for AI compute clusters, InfiniBand\/RoCEv2 fabrics, and hyperscale data center interconnect (DCI), featuring comprehensive digital optical monitoring (DOM) and multi-vendor compatibility.\u003c\/p\u003e\n\n\u003ch3\u003eKey Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized for AI Compute Fabrics:\u003c\/strong\u003e 800Gbps aggregate throughput over 8×100G PAM4 electrical and optical lanes, ideal for high-density spine-leaf switches and GPU server clusters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBroad Multi-Vendor Interoperability:\u003c\/strong\u003e Pre-coded and verified on switches from Cisco, Arista, NVIDIA Quantum-2 QM9700 \/ Spectrum-4, Mellanox, Juniper, and Dell.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow Latency \u0026amp; Low Power Dissipation:\u003c\/strong\u003e High-performance Silicon Photonics (SiPh) \/ EML transmitter design maintaining total power consumption at ≤16W.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDigital Optical Monitoring (DOM):\u003c\/strong\u003e Real-time diagnostics for operating temperature, supply voltage, laser bias current, and transmit\/receive optical power levels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width: 35%;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"width: 65%;\"\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \u0026amp; Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e800G OSFP DR8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e800Gbps (8×100G PAM4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOSFP (Finned \/ Flat Top available)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1310nm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSingle-Mode Fiber (SMF, OS2 \/ G.652)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500m\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDual MPO-12\/APC (MTP-12 APC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModulation Scheme\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8×100G-PAM4 (Electrical \u0026amp; Optical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e≤16W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.3V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransmitter \u0026amp; Detector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSilicon Photonics (SiPh) \/ PIN Receiver\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCMIS 5.2 (Common Management Interface Specification)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0°C ~ 70°C (32°F ~ 158°F) Commercial Grade\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOSFP MSA, IEEE 802.3ck, IEEE 802.3bs, RoHS-6, CE, Class 1 Laser Safety\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSupported\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCompatible Switch Brands\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCisco, Arista, NVIDIA Mellanox (Quantum\/Spectrum), Juniper, Dell\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e800G Optical Transceiver Architecture Comparison\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse; margin-top: 10px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f7f7f7;\"\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n      \u003cth\u003e800G OSFP DR8 (This Model)\u003c\/th\u003e\n      \u003cth\u003e800G OSFP 2xFR4\u003c\/th\u003e\n      \u003cth\u003e800G OSFP SR8\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eReach \/ Distance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500m\u003c\/td\u003e\n      \u003ctd\u003e2km\u003c\/td\u003e\n      \u003ctd\u003e100m (OM4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMedium\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSingle-Mode (SMF)\u003c\/td\u003e\n      \u003ctd\u003eSingle-Mode (SMF)\u003c\/td\u003e\n      \u003ctd\u003eMultimode (MMF, OM4\/OM5)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1310nm Parallel\u003c\/td\u003e\n      \u003ctd\u003eCWDM4 (1271~1331nm)\u003c\/td\u003e\n      \u003ctd\u003e850nm VCSEL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDual MPO-12\/APC\u003c\/td\u003e\n      \u003ctd\u003eDual Duplex LC\u003c\/td\u003e\n      \u003ctd\u003eDual MPO-12\/APC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTypical Application\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAI Spine-Leaf \/ DCI Intra-building\u003c\/td\u003e\n      \u003ctd\u003eCampus \/ Inter-building DCI\u003c\/td\u003e\n      \u003ctd\u003eIntra-Rack \/ Server-to-TOR\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eQuality Assurance \u0026amp; Warranty\u003c\/h3\u003e\n\u003cp\u003eAll transceivers undergo rigorous optical eye pattern testing, bit error rate (BER \u0026lt; 1E-12) verification, and 100% interoperability validation on OEM switches before shipment. Covered by a \u003cstrong\u003e2-year hardware warranty\u003c\/strong\u003e and \u003cstrong\u003elifetime technical support\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eCustom Coding \u0026amp; Sample Requests\u003c\/h3\u003e\n\u003cp\u003eWe support customized vendor EEPROM coding and compatibility testing for enterprise AI data centers. For volume pricing, project sample evaluations, or OEM\/ODM inquiries, please contact our engineering support team.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions \u0026amp; Interoperability\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the YYGL 800G OSFP DR8 transceiver fully compatible with NVIDIA Quantum-2 and Arista 7060X switches?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes. YYGL Optical 800G OSFP DR8 transceivers are pre-coded and hardware-verified for seamless interoperability with NVIDIA Quantum-2 (QM9700\/QM9790) systems, NVIDIA Spectrum-4 platforms, and Arista 7060X5 series switches. Each module runs compliant CMIS 5.0 firmware and supports 8x100G PAM4 modulation over MPO-12\/APC single-mode fiber up to 500 meters, meeting IEEE 802.3ck standards with power consumption below 14W.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can we request pre-coded evaluation samples and switch interop test reports before volume purchase?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes. YYGL Optical provides evaluation sample units for engineering validation. Every batch comes with real-bench optical test reports, including digital sampling oscilloscope eye-diagram metrics, bit error rate (BER) checks, and live traffic test logs across targeted switch vendors.\u003c\/p\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097289699412,"sku":"YY-OSFP-DR8-500M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/800g-osfp-dr8-2.png?v=1795224802"},{"product_id":"yiyuan-400g-qsfp112-vr4-850nm-50m-mpo-12-multimode-optical-transceiver","title":"YYGL 400G QSFP112 VR4 850nm 50m MPO-12 Multimode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 400G QSFP112 VR4 850nm 50m MPO-12 Multimode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 400G QSFP112 VR4\u003c\/strong\u003e is a next-generation 400Gbps multimode optical transceiver engineered for high-density AI compute clusters, GPU fabrics, and hyperscale data center interconnects (DCI). Utilizing advanced 4-channel 100G PAM4 (4x100G-PAM4) electrical and optical lanes with high-speed VCSEL transmitters, it delivers 400Gbps aggregate throughput over OM4 multimode fiber up to 50 meters with ultra-low latency and maximum power dissipation strictly controlled under 9W.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNative 112Gbps SerDes Architecture:\u003c\/strong\u003e Designed for modern switch silicon with 100G\/lane electrical interfaces (4×106.25Gbps PAM4), eliminating power-hungry gearbox DSP latency.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUltra-Low Power Consumption:\u003c\/strong\u003e Maximum power consumption strictly ≤9W, significantly easing thermal dissipation requirements in high-density 1RU\/2RU switch chassis.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Density Optical Interface:\u003c\/strong\u003e MPO-12\/APC optical connector supporting short-reach intra-rack and row-level spine-leaf topologies.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Telemetry \u0026amp; DOM:\u003c\/strong\u003e Fully compliant with CMIS Rev 5.2 with digital optical monitoring (DOM\/DDM) for real-time monitoring of laser bias, temperature, supply voltage, Tx power, and Rx optical power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-QSFP112-VR4-50M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400Gbps (4×100G PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP112 MSA Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultimode Fiber (OM3 \/ OM4 MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Transmission Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50m over OM4 \/ 30m over OM3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel 850nm VCSEL Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReceiver Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel PIN Photodetector Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4×100G PAM4 (Electrical \u0026amp; Optical)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤9.0W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCMIS Rev 5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP112 MSA, IEEE 802.3db, RoHS-6, CE, Class 1 Laser Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (Real-time I2C Diagnostics)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Lab Validation\u003c\/h3\u003e\n\u003cp\u003eEvery YYGL Optical 400G QSFP112 VR4 module undergoes rigorous full-rate bit error rate testing (BER \u0026lt; 1E-12) and optical eye pattern validation on high-bandwidth digital sampling oscilloscopes before shipment. Custom EEPROM microcode programming is available for seamless integration with major switch and router platforms, including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco:\u003c\/strong\u003e Nexus 9000 Series spine-leaf switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista:\u003c\/strong\u003e 7060X and 7050X series platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNVIDIA Mellanox:\u003c\/strong\u003e Quantum-2 InfiniBand and Spectrum Ethernet switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper Networks:\u003c\/strong\u003e QFX and PTX series routers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell Technologies:\u003c\/strong\u003e PowerSwitch Z-series data center switches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: YYGL Optical is an independent manufacturer. Switch brand names are listed solely for hardware interoperability verification.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003eTypical Deployment Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAI Accelerator Interconnect:\u003c\/strong\u003e Direct connection between GPU servers (e.g., NVIDIA HGX\/DGX) and top-of-rack (TOR) switches where short reach (≤50m) and ultra-low latency are essential for distributed machine learning training fabrics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCloud Spine-Leaf Tier:\u003c\/strong\u003e High-density intra-suite aggregation links in modern hyperscale cloud data centers leveraging OM4 structured trunk cabling.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is the difference between QSFP112 and QSFP-DD in 400G optics?\u003c\/h4\u003e\n\u003cp\u003eQSFP112 utilizes 4 electrical lanes running at 100Gbps PAM4 (112G SerDes), matching modern switch silicon directly without needing an internal 8x50G to 4x100G reverse-gearbox DSP. This reduces latency, lowers power consumption (≤9W vs ~12W), and simplifies thermal design compared to older 8-lane QSFP-DD modules.\u003c\/p\u003e\n\n\u003ch4\u003eWhat cabling and connector does the YYGL 400G QSFP112 VR4 require?\u003c\/h4\u003e\n\u003cp\u003eIt requires an MPO-12\/APC multimode fiber patch cable (OM4 recommended for full 50m reach, OM3 for up to 30m). An APC (Angled Physical Contact) polish is required to minimize optical return loss.\u003c\/p\u003e\n\n\u003ch4\u003eCan this module be coded for specific switch vendors?\u003c\/h4\u003e\n\u003cp\u003eYes. YYGL Optical provides customized vendor EEPROM coding for Cisco, Arista, NVIDIA Mellanox, Juniper, and Dell switches. Please provide your switch model and operating system version when requesting an evaluation sample.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Evaluation \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eEngineering sample units and full laboratory test reports (including eye diagrams and BER logs) are available for customer validation. Contact our technical team for volume pricing and compatibility checks.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is the difference between QSFP112 and QSFP-DD in 400G optics?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"QSFP112 utilizes 4 electrical lanes running at 100Gbps PAM4 (112G SerDes), matching modern switch silicon directly without needing an internal 8x50G to 4x100G reverse-gearbox DSP. This reduces latency, lowers power consumption (≤9W vs ~12W), and simplifies thermal design compared to older 8-lane QSFP-DD modules.\"}},{\"@type\":\"Question\",\"name\":\"What cabling and connector does the YYGL 400G QSFP112 VR4 require?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It requires an MPO-12\/APC multimode fiber patch cable (OM4 recommended for full 50m reach, OM3 for up to 30m). An APC (Angled Physical Contact) polish is required to minimize optical return loss.\"}},{\"@type\":\"Question\",\"name\":\"Can this module be coded for specific switch vendors?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. YYGL Optical provides customized vendor EEPROM coding for Cisco, Arista, NVIDIA Mellanox, Juniper, and Dell switches. Please provide your switch model and operating system version when requesting an evaluation sample.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097290027092,"sku":"YY-QSFP112-VR4-50M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/400g-qsfp112-dr4-plus-1.png?v=1795224802"},{"product_id":"yiyuan-400g-qsfp-dd-vr4-850nm-50m-mpo-12-multimode-optical-transceiver","title":"YYGL 400G QSFP-DD VR4 850nm 50m MPO-12 Multimode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 400G QSFP-DD VR4 850nm 50m MPO-12 Multimode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 400G QSFP-DD VR4\u003c\/strong\u003e is a cost-effective 400Gbps multimode optical transceiver designed for enterprise cloud data centers, high-performance computing (HPC) clusters, and top-of-rack (TOR) server interconnects. Operating over 850nm VCSEL arrays, it provides up to 50 meters transmission distance over OM4 multimode fiber via an MPO-12\/APC connector with comprehensive CMIS digital diagnostics.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBroad QSFP-DD Backward Compatibility:\u003c\/strong\u003e Electrical interface supports 8x50G PAM4 host channels, providing seamless plug-and-play operation in existing QSFP-DD switch ports across enterprise data centers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Energy Efficiency:\u003c\/strong\u003e Power consumption is strictly contained at ≤8.0W, reducing total cooling costs in high-density rack deployments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort-Reach Cost Optimization:\u003c\/strong\u003e Optimized for links up to 50m (OM4), offering a highly economical alternative to longer-reach SR4 optics for server-to-switch connectivity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReal-Time Digital Diagnostics (DOM):\u003c\/strong\u003e Built-in CMIS 5.2 compliant telemetry for active monitoring of transceiver temperature, supply voltage, Tx laser bias, and Rx optical power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-QDD-VR4-50M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400Gbps Aggregate Throughput\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP-DD (Double Density) MSA Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultimode Fiber (OM3 \/ OM4 MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50m over OM4 \/ 30m over OM3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter \/ Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850nm VCSEL Array \/ PIN Photodetector Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8×50Gbps PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4×100Gbps PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤8.0W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCMIS Rev 5.2 \/ Rev 4.0\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP-DD MSA, IEEE 802.3db, RoHS-6, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (Real-time telemetry via I2C)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Lab Validation\u003c\/h3\u003e\n\u003cp\u003eEach transceiver is tested for bit error rate (BER \u0026lt; 1E-12) and eye diagram compliance on calibrated test benches. Custom EEPROM microcode is programmed and verified for compatibility with:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco Systems:\u003c\/strong\u003e Nexus 9300 \/ 9500 400G series.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista Networks:\u003c\/strong\u003e 7060DX and 7280R3 series switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNVIDIA Mellanox:\u003c\/strong\u003e SN4700 \/ SN3700 Spectrum Ethernet platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper Networks:\u003c\/strong\u003e QFX5220 and PTX10000 series.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell Technologies:\u003c\/strong\u003e Z9332F-ON and enterprise PowerSwitch series.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDeployment Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTop-of-Rack (TOR) to Spine Links:\u003c\/strong\u003e Ideal for modern leaf-spine data centers where link distances within the data hall or between adjacent racks do not exceed 50 meters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Performance Compute (HPC) Clusters:\u003c\/strong\u003e Provides low-latency, high-throughput interconnects between GPU\/compute nodes and local leaf switches.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eHow does 400G VR4 differ from 400G SR4?\u003c\/h4\u003e\n\u003cp\u003eVR4 is optimized for up to 50m reach over OM4 multimode fiber, whereas SR4 is rated for up to 100m. VR4 optics utilize optimized VCSEL components that offer lower power consumption (≤8W) and lower procurement cost, making them ideal for intra-rack or short-row connections where 100m reach is unnecessary.\u003c\/p\u003e\n\n\u003ch4\u003eWhat optical patch cord is needed for 400G QSFP-DD VR4?\u003c\/h4\u003e\n\u003cp\u003eA standard 8-fiber or 12-fiber MPO-12\/APC multimode (OM3 or OM4) patch cable is required. APC (Angled Physical Contact) polish is necessary to maintain proper optical return loss.\u003c\/p\u003e\n\n\u003ch4\u003eCan I request custom switch coding before delivery?\u003c\/h4\u003e\n\u003cp\u003eYes. YYGL Optical encodes each order to match your switch environment (Cisco, Arista, NVIDIA, etc.) to ensure seamless recognition and zero compatibility warning flags.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Evaluation \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eEvaluation samples and batch optical test reports are available upon request. Contact our sales engineering team to verify switch model compatibility or discuss volume pricing.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"How does 400G VR4 differ from 400G SR4?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"VR4 is optimized for up to 50m reach over OM4 multimode fiber, whereas SR4 is rated for up to 100m. VR4 optics utilize optimized VCSEL components that offer lower power consumption (≤8W) and lower procurement cost, making them ideal for intra-rack or short-row connections where 100m reach is unnecessary.\"}},{\"@type\":\"Question\",\"name\":\"What optical patch cord is needed for 400G QSFP-DD VR4?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A standard 8-fiber or 12-fiber MPO-12\/APC multimode (OM3 or OM4) patch cable is required. APC (Angled Physical Contact) polish is necessary to maintain proper optical return loss.\"}},{\"@type\":\"Question\",\"name\":\"Can I request custom switch coding before delivery?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. YYGL Optical encodes each order to match your switch environment (Cisco, Arista, NVIDIA, etc.) to ensure seamless recognition and zero compatibility warning flags.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097290092628,"sku":"YY-QSFPDD-VR4-50M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/3_121cd592-ea23-49d4-a6b2-a45146e21fef.jpg?v=1781762389"},{"product_id":"yiyuan-400g-osfp-rhs-dr4-1310nm-500m-mpo-12-single-mode-optical-transceiver","title":"YYGL 400G OSFP-RHS DR4 1310nm 500m MPO-12 Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 400G OSFP-RHS DR4 1310nm 500m MPO-12 Single-Mode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 400G OSFP-RHS DR4\u003c\/strong\u003e is a high-density, low-power single-mode optical transceiver designed for AI infrastructure clusters, hyperscale cloud data center leaf-to-spine fabrics, and 4x100G breakout connections. Packaged in the compact OSFP-RHS (Riding Heat Sink) form factor, it delivers 400Gbps transmission up to 500 meters over standard single-mode fiber (SMF) via an MPO-12\/APC connector.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOSFP-RHS Compact Form Factor:\u003c\/strong\u003e Engineered for high-density compute platforms and AI network switches with integrated Riding Heat Sink (RHS) thermal design.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSingle-Mode Parallel Optics:\u003c\/strong\u003e Operates at 1310nm uncooled EML \/ Silicon Photonics (SiPh) over standard G.652 single-mode fiber up to 500 meters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersatile 400G to 4x100G Breakout:\u003c\/strong\u003e Supports 400Gbps aggregation as well as direct optical breakout to four 100G DR \/ 100G-PAM4 QSFP28\/SFP-DD optical modules using an MPO-to-4xLC breakout cable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStrict Power Budget:\u003c\/strong\u003e Designed for demanding thermal environments, keeping maximum power consumption below 10.0W.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCMIS 5.2 Digital Diagnostics:\u003c\/strong\u003e Full digital optical monitoring (DOM) over I2C interface for real-time laser bias, temperature, supply voltage, and Tx\/Rx optical power levels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-OSFP-RHS-DR4-500M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400Gbps (4×100G PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSFP-RHS (Riding Heat Sink) MSA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1310nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode Fiber (OS2 \/ G.652 SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500m\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC (Parallel Single-Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel 1310nm Silicon Photonics (SiPh) \/ EML\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReceiver Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel PIN Photodetector\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤10.0W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCMIS Rev 5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSFP MSA, IEEE 802.3bs, IEEE 802.3ck, RoHS-6, CE, Class 1 Laser\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (Real-time I2C Diagnostics)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Lab Validation\u003c\/h3\u003e\n\u003cp\u003eEach module is verified on live switch test beds for 100% interoperability and bit error rate performance (BER \u0026lt; 1E-12). Pre-coded firmware is available for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNVIDIA Mellanox:\u003c\/strong\u003e Quantum-2 InfiniBand and Spectrum-3\/Spectrum-4 Ethernet switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista Networks:\u003c\/strong\u003e 7060X series OSFP-RHS platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco Systems:\u003c\/strong\u003e Nexus 9000 cloud switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper Networks:\u003c\/strong\u003e High-density PTX and QFX platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell Technologies:\u003c\/strong\u003e High-density PowerSwitch systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTarget Application Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAI Spine-Leaf Infrastructure:\u003c\/strong\u003e Ideal for interconnecting AI server pods equipped with OSFP-RHS network interface cards (NICs) to spine-leaf switch tiers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4x100G Optical Breakout:\u003c\/strong\u003e Connects a single 400G OSFP-RHS port directly to four distinct 100G DR1 single-mode ports across legacy 100G switches, preserving cabling investment.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is OSFP-RHS and is it compatible with standard OSFP ports?\u003c\/h4\u003e\n\u003cp\u003eOSFP-RHS (Riding Heat Sink) is a standardized, more compact variant of the OSFP form factor where the heat sink is mounted on the switch cage rather than permanently bonded to the transceiver module. OSFP-RHS modules must be plugged into dedicated OSFP-RHS cages, which are commonly found on NVIDIA Mellanox and modern high-density AI platforms.\u003c\/p\u003e\n\n\u003ch4\u003eCan this transceiver break out to four 100G links?\u003c\/h4\u003e\n\u003cp\u003eYes. The 400G DR4 optical architecture uses 4 parallel single-mode fiber pairs. Using an MPO-12\/APC to 4x Duplex LC breakout single-mode cable, you can connect this module to four 100G DR \/ 100G-PAM4 transceivers.\u003c\/p\u003e\n\n\u003ch4\u003eWhat optical connector polish is required?\u003c\/h4\u003e\n\u003cp\u003eMPO-12\/APC (Angled Physical Contact, 8-degree angle) polish is strictly required. Never connect flat UPC connectors to APC interfaces, as it causes severe optical back-reflection and potential connector damage.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Requests \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eEvaluation samples with full optical test reports and EEPROM verification logs are available. Contact YYGL Optical technical sales for project quotations and lead time confirmations.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is OSFP-RHS and is it compatible with standard OSFP ports?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"OSFP-RHS (Riding Heat Sink) is a standardized, more compact variant of the OSFP form factor where the heat sink is mounted on the switch cage rather than permanently bonded to the transceiver module. OSFP-RHS modules must be plugged into dedicated OSFP-RHS cages, which are commonly found on NVIDIA Mellanox and modern high-density AI platforms.\"}},{\"@type\":\"Question\",\"name\":\"Can this transceiver break out to four 100G links?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. The 400G DR4 optical architecture uses 4 parallel single-mode fiber pairs. Using an MPO-12\/APC to 4x Duplex LC breakout single-mode cable, you can connect this module to four 100G DR \/ 100G-PAM4 transceivers.\"}},{\"@type\":\"Question\",\"name\":\"What optical connector polish is required?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"MPO-12\/APC (Angled Physical Contact, 8-degree angle) polish is strictly required. Never connect flat UPC connectors to APC interfaces, as it causes severe optical back-reflection and potential connector damage.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097290158164,"sku":"YY-OSFP-RHS-DR4-500M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/1_799ac29d-976c-4c77-b421-b79b75750ed7.jpg?v=1781763124"},{"product_id":"yiyuan-400g-qsfp-dd-sr8-850nm-100m-mpo-16-multimode-optical-transceiver","title":"YYGL 400G QSFP-DD SR8 850nm 100m MPO-16 Multimode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 400G QSFP-DD SR8 850nm 100m MPO-16 Multimode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 400G QSFP-DD SR8\u003c\/strong\u003e is a high-bandwidth 8-channel optical transceiver designed for enterprise cloud data centers, high-performance computing (HPC), and 400G to 2x200G breakout network architectures. Operating at 850nm over OM4 multimode fiber via an MPO-16\/APC connector, it provides up to 100 meters reach with robust signal integrity and digital optical monitoring.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e8×50G PAM4 Optical Architecture:\u003c\/strong\u003e Features an 8-channel VCSEL transmitter array operating at 53.125Gbps PAM4 per lane, perfectly matched to 50G SerDes switch architectures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible 2×200G or 8×50G Breakout:\u003c\/strong\u003e Supports high-density 400G trunk links or optical breakout to two 200G SR4 modules or eight 50G optical links via structured MPO-16 cabling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended Multimode Reach:\u003c\/strong\u003e Delivers up to 100 meters over OM4 multimode fiber (70 meters over OM3), meeting all intra-data center inter-rack connectivity needs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive CMIS Telemetry:\u003c\/strong\u003e Supports CMIS management interface with real-time DOM monitoring of laser bias, temperature, supply voltage, and Tx\/Rx power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-QDD-SR8-100M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400Gbps (8×50G PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP-DD Type 2 MSA Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultimode Fiber (OM3 \/ OM4 MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100m over OM4 \/ 70m over OM3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-16\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter \/ Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8-Channel 850nm VCSEL Array \/ PIN Photodetector Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤10.0W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCMIS Rev 5.2 \/ Rev 4.0\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP-DD MSA, IEEE 802.3cm, IEEE 802.3cd, RoHS-6, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (Real-time I2C Diagnostics)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Lab Validation\u003c\/h3\u003e\n\u003cp\u003eEach module is tested for low bit error rate (BER \u0026lt; 1E-12) and eye pattern margin on high-speed digital sampling oscilloscopes. Pre-coded EEPROM configurations are available for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco:\u003c\/strong\u003e Nexus 9300 and 9500 modular switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista:\u003c\/strong\u003e 7060X and 7280R series platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNVIDIA Mellanox:\u003c\/strong\u003e Spectrum Ethernet switch platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper:\u003c\/strong\u003e QFX5200 and PTX series routers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell:\u003c\/strong\u003e PowerSwitch data center series.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTypical Deployment Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSpine-to-Leaf Aggregation:\u003c\/strong\u003e High-density 400Gbps uplink connectivity in enterprise data centers using existing MPO-16 multimode trunk cabling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2x200G Breakout Links:\u003c\/strong\u003e Connecting a 400G switch port to two 200G QSFP56 SR4 switch ports using an MPO-16 to 2x MPO-12 breakout cable.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhy does the 400G QSFP-DD SR8 use an MPO-16 connector instead of MPO-12?\u003c\/h4\u003e\n\u003cp\u003eBecause the SR8 architecture uses 8 optical transmit lanes and 8 optical receive lanes (total 16 fibers), it requires a 16-fiber MPO-16\/APC connector. MPO-12 connectors only support up to 4 bi-directional lanes (8 active fibers).\u003c\/p\u003e\n\n\u003ch4\u003eCan this module interoperate with 200G QSFP56 SR4 transceivers?\u003c\/h4\u003e\n\u003cp\u003eYes. By using an MPO-16\/APC to 2x MPO-12\/APC breakout cable, this 400G SR8 module can split into two 200G SR4 links (each running 4x50G PAM4), facilitating phased network upgrades.\u003c\/p\u003e\n\n\u003ch4\u003eIs digital optical monitoring (DOM) supported?\u003c\/h4\u003e\n\u003cp\u003eYes. Full real-time DOM telemetry is supported over the I2C management interface per CMIS specifications, allowing network operators to continuously track laser health and optical link quality.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Evaluation \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eLab evaluation samples and custom vendor coding are available upon request. Contact YYGL Optical for enterprise pricing and availability.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Why does the 400G QSFP-DD SR8 use an MPO-16 connector instead of MPO-12?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Because the SR8 architecture uses 8 optical transmit lanes and 8 optical receive lanes (total 16 fibers), it requires a 16-fiber MPO-16\/APC connector. MPO-12 connectors only support up to 4 bi-directional lanes (8 active fibers).\"}},{\"@type\":\"Question\",\"name\":\"Can this module interoperate with 200G QSFP56 SR4 transceivers?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. By using an MPO-16\/APC to 2x MPO-12\/APC breakout cable, this 400G SR8 module can split into two 200G SR4 links (each running 4x50G PAM4), facilitating phased network upgrades.\"}},{\"@type\":\"Question\",\"name\":\"Is digital optical monitoring (DOM) supported?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Full real-time DOM telemetry is supported over the I2C management interface per CMIS specifications, allowing network operators to continuously track laser health and optical link quality.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097290223700,"sku":"YY-QSFPDD-SR8-400G-100M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/400g-qsfp-dd-sr4-1.png?v=1795224801"},{"product_id":"yiyuan-400g-osfp-rhs-vr4-850nm-50m-mpo-12-multimode-optical-transceiver","title":"YYGL 400G OSFP-RHS VR4 850nm 50m MPO-12 Multimode Optical Transceiver","description":"\u003ch2\u003eYYGL 400G OSFP-RHS VR4 850nm 50m MPO-12 Multimode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 400G OSFP-RHS VR4\u003c\/strong\u003e is a 400G OSFP-RHS multimode optical transceiver operating at 850nm, supporting transmission distances of 30m (OM3) \/ 50m (OM4) over multimode fiber (MMF) with an MPO-12\/APC connector. It is designed for data center interconnect (DCI) and AI computing cluster networks, with digital optical monitoring (DOM) support.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400G OSFP-RHS VR4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSFP-RHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultimode (MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30m (OM3) \/ 50m (OM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation (Electrical Port)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4x100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation (Optical Port)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4x100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤9W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVCSEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C ~ 70°C (32°F ~ 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSFP MSA, CMIS Rev 5.2, IEEE 802.3db\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDOM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Brands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCisco, Arista, Mellanox, Juniper, Dell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoHS, CE, Class 1 Laser Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097290354772,"sku":"YY-OSFP-RHS-VR4-50M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/1_799ac29d-976c-4c77-b421-b79b75750ed7.jpg?v=1781763124"},{"product_id":"yiyuan-400g-osfp-rhs-sr4-850nm-100m-mpo-12-multimode-optical-transceiver","title":"YYGL 400G OSFP-RHS SR4 850nm 100m MPO-12 Multimode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 400G OSFP-RHS SR4 850nm 100m MPO-12 Multimode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 400G OSFP-RHS SR4\u003c\/strong\u003e is an ultra-low latency, high-density 400Gbps multimode optical transceiver designed for GPU server clusters, AI computing pods, and leaf-to-spine interconnects. Built in the compact OSFP-RHS form factor, it delivers 400Gbps aggregate bandwidth over OM4 multimode fiber up to 100 meters via an MPO-12\/APC connector with power consumption strictly under 9.0W.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEngineered for Modern AI Fabrics:\u003c\/strong\u003e Native 4×100G PAM4 architecture operates directly with 100G\/lane switch silicon and GPU network interface cards without gearbox latency.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact OSFP-RHS Package:\u003c\/strong\u003e Riding Heat Sink form factor ensures optimal thermal dissipation in high-density 1RU\/2RU switch chassis and multi-GPU compute servers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended 100m Multimode Reach:\u003c\/strong\u003e Supports up to 100 meters over OM4 fiber (70m over OM3), perfectly covering all intra-data center row and pod connections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnergy Efficient Operation:\u003c\/strong\u003e Total power dissipation strictly controlled at ≤9.0W, minimizing cooling overhead in dense GPU cluster environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCMIS 5.2 Diagnostics:\u003c\/strong\u003e Real-time digital optical monitoring (DOM) for laser bias current, temperature, supply voltage, and Tx\/Rx optical power levels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-OSFP-RHS-SR4-100M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400Gbps (4×100G PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSFP-RHS (Riding Heat Sink)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultimode Fiber (OM3 \/ OM4 MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100m over OM4 \/ 70m over OM3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter \/ Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel 850nm VCSEL Array \/ PIN Photodetector Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤9.0W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCMIS Rev 5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSFP MSA, IEEE 802.3db, RoHS-6, CE, Class 1 Laser\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (Real-time I2C Diagnostics)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Lab Validation\u003c\/h3\u003e\n\u003cp\u003eEach module is verified for bit error rate (BER \u0026lt; 1E-12) and eye pattern margin on high-speed digital sampling oscilloscopes. Pre-coded EEPROM configurations are available for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNVIDIA Mellanox:\u003c\/strong\u003e Quantum-2 InfiniBand and Spectrum-4 Ethernet switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista Networks:\u003c\/strong\u003e 7060X series OSFP-RHS switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco Systems:\u003c\/strong\u003e Nexus 9000 cloud switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper Networks:\u003c\/strong\u003e QFX and PTX series routers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell Technologies:\u003c\/strong\u003e PowerSwitch data center series.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTarget Application Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGPU Pod Cluster Interconnect:\u003c\/strong\u003e High-density interconnects between NVIDIA HGX\/DGX GPU systems and leaf switches requiring compact OSFP-RHS cages.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntra-Suite Multimode Spine-Leaf:\u003c\/strong\u003e High-bandwidth, low-power aggregation links across compute rows using OM4 structured cabling.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eHow does the OSFP-RHS SR4 compare with OSFP-RHS VR4?\u003c\/h4\u003e\n\u003cp\u003eThe SR4 model is rated for up to 100 meters over OM4 fiber, whereas the VR4 is optimized for up to 50 meters. Choose SR4 when your inter-rack or pod cabling spans beyond 50m.\u003c\/p\u003e\n\n\u003ch4\u003eWhat optical patch cable should be used with this transceiver?\u003c\/h4\u003e\n\u003cp\u003eUse an MPO-12\/APC (Angled Physical Contact) multimode fiber patch cord (OM4 recommended). APC polish is required to ensure optimal optical return loss.\u003c\/p\u003e\n\n\u003ch4\u003eCan this module be coded for specific switch environments?\u003c\/h4\u003e\n\u003cp\u003eYes. YYGL Optical provides pre-coded EEPROM settings tailored for NVIDIA, Arista, Cisco, and Juniper switches to guarantee seamless link bring-up and clean telemetry reporting.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Evaluation \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eEngineering evaluation samples with comprehensive lab test reports are available. Contact YYGL Optical to verify compatibility or request a volume quotation.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"How does the OSFP-RHS SR4 compare with OSFP-RHS VR4?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The SR4 model is rated for up to 100 meters over OM4 fiber, whereas the VR4 is optimized for up to 50 meters. Choose SR4 when your inter-rack or pod cabling spans beyond 50m.\"}},{\"@type\":\"Question\",\"name\":\"What optical patch cable should be used with this transceiver?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Use an MPO-12\/APC (Angled Physical Contact) multimode fiber patch cord (OM4 recommended). APC polish is required to ensure optimal optical return loss.\"}},{\"@type\":\"Question\",\"name\":\"Can this module be coded for specific switch environments?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. YYGL Optical provides pre-coded EEPROM settings tailored for NVIDIA, Arista, Cisco, and Juniper switches to guarantee seamless link bring-up and clean telemetry reporting.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097290485844,"sku":"YY-OSFP-RHS-SR4-100M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/1_799ac29d-976c-4c77-b421-b79b75750ed7.jpg?v=1781763124"},{"product_id":"yiyuan-400g-qsfp112-sr4-850nm-100m-mpo-12-multimode-optical-transceiver","title":"YYGL 400G QSFP112 SR4 850nm 100m MPO-12 Multimode Optical Transceiver","description":"\u003ch2\u003eYYGL 400G QSFP112 SR4 850nm 100m MPO-12 Multimode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 400G QSFP112 SR4\u003c\/strong\u003e is a 400G QSFP112 multimode optical transceiver operating at 850nm, supporting transmission distances of 60m (OM3) \/ 100m (OM4) over multimode fiber (MMF) with an MPO-12\/APC connector. It is designed for data center interconnect (DCI) and AI computing cluster networks, with digital optical monitoring (DOM) support.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400G QSFP112 SR4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultimode (MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60m (OM3) \/ 100m (OM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation (Electrical Port)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4x100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation (Optical Port)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4x100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤9W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVCSEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C ~ 70°C (32°F ~ 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP112 MSA, CMIS Rev 5.2, IEEE 802.3db\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDOM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Brands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCisco, Arista, Mellanox, Juniper, Dell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoHS, CE, Class 1 Laser Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097290780756,"sku":"YY-QSFP112-SR4-100M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/6_65de0842-47dc-4cd7-b1ba-3191e9d8e707.jpg?v=1782886599"},{"product_id":"yiyuan-400g-qsfp112-dr4-1310nm-2km-mpo-12-single-mode-optical-transceiver","title":"YYGL 400G QSFP112 DR4+ 1310nm 2km MPO-12 Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL 400G QSFP112 DR4+ 1310nm 2km MPO-12 Single-Mode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 400G QSFP112 DR4+\u003c\/strong\u003e is a 400G QSFP112 single-mode optical transceiver operating at 1310nm, supporting transmission distances of 2km over single-mode fiber (SMF) with an MPO-12\/APC connector. It is designed for data center interconnect (DCI) and AI computing cluster networks, with digital optical monitoring (DOM) support.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400G QSFP112 DR4+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1310nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode (SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation (Electrical Port)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4x100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation (Optical Port)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4x100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤9W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiPh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C ~ 70°C (32°F ~ 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP112 MSA, CMIS Rev 5.2, IEEE 802.3bs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDOM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Brands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCisco, Arista, Mellanox, Juniper, Dell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoHS, CE, Class 1 Laser Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097291075668,"sku":"YY-QSFP112-DR4P-2KM","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/400g-qsfp112-dr4-plus-1.png?v=1795224802"},{"product_id":"yiyuan-400g-qsfp112-dr4-1310nm-500m-mpo-12-single-mode-optical-transceiver","title":"YYGL 400G QSFP112 DR4 1310nm 500m MPO-12 Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 400G QSFP112 DR4 1310nm 500m MPO-12 Single-Mode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 400G QSFP112 DR4\u003c\/strong\u003e is a high-performance 400Gbps single-mode optical transceiver designed for next-generation AI compute clusters, hyperscale cloud data centers, and high-density spine-leaf networks. Operating at 1310nm over single-mode fiber (SMF) up to 500 meters via an MPO-12\/APC connector, it utilizes native 112Gbps SerDes electrical interfaces to provide unmatched latency performance and power efficiency below 10.0W.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNative 4×100G PAM4 Architecture:\u003c\/strong\u003e Designed for advanced switch silicon with native 112G SerDes ports, eliminating reverse-gearbox latency and optimizing thermal dissipation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSingle-Mode Parallel Reach:\u003c\/strong\u003e Transmits up to 500 meters over standard OS2 \/ G.652 single-mode fiber (SMF) using high-reliability 1310nm Silicon Photonics (SiPh) \/ EML transmitters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupports 4x100G Breakout:\u003c\/strong\u003e Can be deployed for direct 400G-to-400G connections or broken out into four 100G DR \/ 100G-PAM4 single-mode links via an MPO-to-4xLC breakout cable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStrict Power Control:\u003c\/strong\u003e Maximum power dissipation is strictly contained at ≤10.0W, reducing data center cooling overhead.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCMIS 5.2 Digital Diagnostics:\u003c\/strong\u003e Compliant with Common Management Interface Specification (CMIS) Rev 5.2 for real-time telemetry of temperature, supply voltage, laser bias, and optical power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-QSFP112-DR4-500M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400Gbps (4×100G PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP112 MSA Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1310nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode Fiber (OS2 \/ G.652 SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500m\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC (Parallel Single-Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter \/ Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel 1310nm SiPh\/EML \/ PIN Photodetector Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation Scheme\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4×100G PAM4 (Electrical \u0026amp; Optical)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤10.0W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCMIS Rev 5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP112 MSA, IEEE 802.3cu, IEEE 802.3ck, RoHS-6, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (Real-time I2C Diagnostics)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Lab Validation\u003c\/h3\u003e\n\u003cp\u003eEach transceiver is tested for bit error rate (BER \u0026lt; 1E-12) and optical eye diagram margin on digital sampling oscilloscopes. Pre-coded EEPROM firmware is available for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco:\u003c\/strong\u003e Nexus 9000 series cloud switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista:\u003c\/strong\u003e 7060X series QSFP112 platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNVIDIA Mellanox:\u003c\/strong\u003e Spectrum Ethernet and Quantum-2 switch systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper:\u003c\/strong\u003e High-density PTX and QFX platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell:\u003c\/strong\u003e PowerSwitch data center series.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDeployment Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHyperscale Spine-Leaf Interconnect:\u003c\/strong\u003e High-density 400Gbps single-mode links between leaf and spine switches spanning up to 500 meters across data halls.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptical Breakout to 4x100G:\u003c\/strong\u003e Using an MPO-12\/APC to 4x Duplex LC single-mode cable, this transceiver breaks out seamlessly into four 100G DR optical transceivers.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is the difference between QSFP112 DR4 and QSFP-DD DR4?\u003c\/h4\u003e\n\u003cp\u003eQSFP112 uses 4 electrical lanes running at 100Gbps PAM4, matching 112G SerDes switch chips directly without an internal 8x50G-to-4x100G gearbox DSP. This provides lower latency, lower power consumption, and simpler thermal dissipation than 8-lane QSFP-DD modules.\u003c\/p\u003e\n\n\u003ch4\u003eCan this transceiver interoperate with 100G DR transceivers?\u003c\/h4\u003e\n\u003cp\u003eYes. The optical lane parameters conform to IEEE 802.3cu 100G-DR standards. Using an MPO-12\/APC to 4x LC breakout single-mode cable, each optical lane links directly to an independent 100G DR transceiver.\u003c\/p\u003e\n\n\u003ch4\u003eWhat optical connector is required?\u003c\/h4\u003e\n\u003cp\u003eAn MPO-12\/APC single-mode patch cord (8-degree angled polish) is required. Ensure both ends use APC polish to prevent back-reflection damage.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Evaluation \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eEvaluation samples with full optical test reports and EEPROM verification logs are available. Contact YYGL Optical technical sales for project quotations and lead time confirmations.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is the difference between QSFP112 DR4 and QSFP-DD DR4?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"QSFP112 uses 4 electrical lanes running at 100Gbps PAM4, matching 112G SerDes switch chips directly without an internal 8x50G-to-4x100G gearbox DSP. This provides lower latency, lower power consumption, and simpler thermal dissipation than 8-lane QSFP-DD modules.\"}},{\"@type\":\"Question\",\"name\":\"Can this transceiver interoperate with 100G DR transceivers?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. The optical lane parameters conform to IEEE 802.3cu 100G-DR standards. Using an MPO-12\/APC to 4x LC breakout single-mode cable, each optical lane links directly to an independent 100G DR transceiver.\"}},{\"@type\":\"Question\",\"name\":\"What optical connector is required?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"An MPO-12\/APC single-mode patch cord (8-degree angled polish) is required. Ensure both ends use APC polish to prevent back-reflection damage.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097291305044,"sku":"YY-QSFP112-DR4-500M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/400g-qsfp112-dr4-plus-1.png?v=1795224802"}],"url":"https:\/\/yiyuanguanglink.com\/es\/collections\/optical-transceivers.oembed?page=2","provider":"YYGL Optical","version":"1.0","type":"link"}