{"title":"400G Data Center Optics","description":"\u003cp\u003eEnterprise and hyperscale 400G optical transceivers across QSFP-DD, OSFP-RHS, and QSFP112 form factors. 100% pre-tested with multi-vendor compatibility.\u003c\/p\u003e","products":[{"product_id":"400g-qsfp-dd-sr4-pam4-850nm-100m-dom-mpo-12-apc-multimode-optical-module","title":"YYGL 400G QSFP-DD SR4 850nm 100m MPO-12 Multimode Optical Transceiver","description":"\u003ch2\u003eYYGL 400G QSFP-DD SR4 Multimode Optical Transceiver | 850nm | 100m | MPO-12 | DOM\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 400G QSFP-DD SR4\u003c\/strong\u003e transceiver delivers \u003cstrong\u003e400Gbps over 100 meters of OM4 multimode fiber\u003c\/strong\u003e using 4×100G PAM4 parallel channels at 850nm. A cost-effective, high-density solution for data center leaf-spine fabric, AI cluster interconnects, and enterprise core switching upgrades.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e400Gbps in QSFP-DD:\u003c\/strong\u003e High port density for leaf-spine and core switching deployments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e100m OM4 Reach:\u003c\/strong\u003e Covers standard data center hall distances with existing MMF infrastructure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPO-12 Connector:\u003c\/strong\u003e Industry-standard interface compatible with pre-terminated fiber assemblies.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePAM4 Modulation:\u003c\/strong\u003e 4×100G parallel architecture for efficient multimode fiber use.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDOM Supported:\u003c\/strong\u003e Real-time monitoring of optical power, temperature, and voltage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQSFP-DD MSA Compliant:\u003c\/strong\u003e Conforms to QSFP-DD MSA and CMIS Rev 5.2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; background-color: #f4f6f8; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; background-color: #f4f6f8; text-align: left;\"\u003eValue \/ Parameter\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eYY-QSFPDD-SR4-100M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e400Gbps (4×100Gbps PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eQSFP-DD\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Transmitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e4-Channel VCSEL Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003ePIN Photodetector Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eMultimode Fiber (OM3 \/ OM4 MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eMaximum Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e100m over OM4 \/ 60m over OM3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eMPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e≤8W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e3.3V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e0°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eCMIS Rev 5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eStandards \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eQSFP-DD MSA, IEEE 802.3db\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eDigital Diagnostics (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eHost Coding Available For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eCisco, Arista, NVIDIA Mellanox, Juniper, Dell\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eCompliance Documents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eAvailable per SKU on request\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHost Coding \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003ePre-coded and tested on OEM host switches including Cisco Nexus, Arista, NVIDIA Mellanox, and Juniper platforms.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is the power consumption of 400G QSFP-DD SR4?\u003c\/h4\u003e\n\u003cp\u003eThe module features an ultra-low power design of ≤8W, preventing thermal throttling.\u003c\/p\u003e\n\u003ch4\u003eWhich fiber and connector are required?\u003c\/h4\u003e\n\u003cp\u003eIt uses MPO-12\/APC connectors over OM3\/OM4 multimode fiber (up to 100m on OM4).\u003c\/p\u003e\n\u003ch4\u003eCan this module breakout to 4x100G?\u003c\/h4\u003e\n\u003cp\u003eYes, it supports breakout configurations to 4x 100G SR links on compatible switch ports.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eOrdering \u0026amp; RFQ Information\u003c\/h3\u003e\n\u003cp\u003eSubmit an RFQ for engineering evaluation samples and tiered volume pricing.\u003c\/p\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092801011796,"sku":"YY-QSFPDD-SR4-100M","price":272.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/400g-qsfp-dd-sr4-1.png?v=1795224801"},{"product_id":"400g-qsfp-dd-fr4-pam4-1310nm-2km-dom-lc-duplex-single-mode-optical-module","title":"YYGL 400G QSFP-DD FR4 1310nm 2km LC Duplex Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL 400G QSFP-DD FR4 Single-Mode Optical Transceiver | PAM4 | 1310nm | 2km | LC Duplex | DOM\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 400G QSFP-DD FR4\u003c\/strong\u003e transceiver delivers 400Gbps over 2km of OS2 single-mode fiber (SMF) using 4-wavelength CWDM4 technology over standard LC duplex connectors. Engineered for data center interconnect (DCI), campus backbones, and enterprise core networks requiring extended SMF reach without replacing duplex fiber cabling infrastructure.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e2km Extended Single-Mode Reach:\u003c\/strong\u003e Delivers 400Gbps over standard duplex SMF, ideal for campus-scale backbone links and inter-building DCI.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCWDM4 Multiplexing Efficiency:\u003c\/strong\u003e Multiplexes 4×100G optical lanes onto a single duplex fiber pair, significantly saving optical cabling costs compared to parallel MPO solutions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal LC Duplex Interface:\u003c\/strong\u003e Directly compatible with existing LC patch panels and structured telecom fiber plant.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHost Coding:\u003c\/strong\u003e Coding available for Cisco, Arista, NVIDIA Mellanox, Juniper, or Dell switches; we check coding for your switch model before you order.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDigital Optical Monitoring (DOM):\u003c\/strong\u003e Comprehensive real-time monitoring of operating temperature, supply voltage, laser bias current, and TX\/RX optical power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width: 35%;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"width: 65%;\"\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \u0026amp; Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e400G QSFP-DD FR4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e400Gbps (4×100G PAM4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eQSFP-DD Type 2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWavelength Grid\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCWDM4 (1271nm, 1291nm, 1311nm, 1331nm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSingle-Mode Fiber (SMF, OS2 \/ G.652)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2km\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard LC Duplex\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModulation Scheme\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4×100G-PAM4 CWDM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e≤10W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.3V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransmitter \u0026amp; Detector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCWDM EML Transmitter \u0026amp; PIN Receiver\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCMIS 4.0 \/ CMIS 5.0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0°C ~ 70°C (32°F ~ 158°F) Commercial Grade\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eQSFP-DD MSA, 100G Lambda MSA 400G-FR4, IEEE 802.3bs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSupported\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCoding Available For\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCisco, Arista, NVIDIA Mellanox, Juniper, Dell\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e400G Single-Mode Architecture Comparison\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse; margin-top: 10px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f7f7f7;\"\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n      \u003cth\u003e400G QSFP-DD FR4 (This Model)\u003c\/th\u003e\n      \u003cth\u003e400G QSFP-DD DR4\u003c\/th\u003e\n      \u003cth\u003e400G QSFP-DD LR4\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2km\u003c\/td\u003e\n      \u003ctd\u003e500m\u003c\/td\u003e\n      \u003ctd\u003e10km\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFiber Connector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLC Duplex (2 Fibers)\u003c\/td\u003e\n      \u003ctd\u003eMPO-12\/APC (8 Active Fibers)\u003c\/td\u003e\n      \u003ctd\u003eLC Duplex (2 Fibers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOptical Multiplexing\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCWDM4 (Wavelength Mux)\u003c\/td\u003e\n      \u003ctd\u003eParallel Single-Mode (PSM4)\u003c\/td\u003e\n      \u003ctd\u003eLWDM4 \/ LAN-WDM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFiber Infrastructure Cost\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLow (Reuses existing 2-fiber LC plant)\u003c\/td\u003e\n      \u003ctd\u003eRequires parallel MPO-12 trunking\u003c\/td\u003e\n      \u003ctd\u003eLow (Reuses existing 2-fiber LC plant)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTarget Application\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCampus Backbone \u0026amp; Inter-building DCI\u003c\/td\u003e\n      \u003ctd\u003eIntra-Building Spine-Leaf \u0026amp; Breakout\u003c\/td\u003e\n      \u003ctd\u003eMetro Edge \u0026amp; Telecom Core\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eQuality Assurance \u0026amp; Testing\u003c\/h3\u003e\n\u003cp\u003eEach module is tested before dispatch. Our test process includes 3D end-face interferometry, optical eye-diagram checks, bit error rate checks, and switch port link testing. Ask us for test records for this SKU. Engineering support is available when you inquire.\u003c\/p\u003e\n\n\u003ch3\u003eCustom Coding \u0026amp; Sample Inquiries\u003c\/h3\u003e\n\u003cp\u003eWe provide custom EEPROM coding for Cisco, Arista, NVIDIA Mellanox, Juniper, or Dell hosts. Compatibility depends on the host platform. Please share your switch model, software version, module type, link distance and fiber type so we can check coding and compatibility before you order. YYGL Optical is an independent optics supplier; we are not those brands and we do not claim affiliation with them. For volume pricing, project sample requests, or custom cabling configurations, please submit an inquiry or contact our engineering sales team.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions \u0026amp; Interoperability\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does YYGL Optical ensure 400G QSFP-DD transceiver compatibility with Cisco Nexus 9000 and Arista switches?\u003c\/strong\u003e\u003cbr\u003e\nA: YYGL Optical programs custom EEPROM vendor coding into each 400G QSFP-DD module to ensure non-alarm recognition on Cisco Nexus 9300\/9400 series (supporting service unsupported-transceiver bypass when required) and Arista EOS hosts. Built with high-reliability COB packaging, our 400G modules deliver lower thermal resistance and typical power consumption under 10W.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does YYGL Optical support custom EEPROM programming for mixed-vendor data center architectures?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes. Because modern hyperscale fabrics frequently deploy mixed switch platforms, our engineering team offers bespoke firmware flashing for multi-vendor environments, allowing seamless link establishment across disparate spine-leaf tiers.\u003c\/p\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092801044564,"sku":"YY-QSFPDD-FR4-2KM","price":341.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/400g-fr4-qsfpdd.jpg?v=1793931406"},{"product_id":"400g-qsfp-dd-dr4-pam4-1310nm-500m-dom-mpo-12-apc-single-mode-optical-module","title":"YYGL 400G QSFP-DD DR4 1310nm 500m MPO-12 Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL 400G QSFP-DD DR4 Single-Mode Optical Transceiver | PAM4 | 1310nm | 500m | MPO-12\/APC | DOM\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 400G QSFP-DD DR4\u003c\/strong\u003e transceiver delivers 400Gbps over 500 meters of OS2 single-mode fiber (SMF) using 4×100G PAM4 parallel optical channels at 1310nm with an MPO-12\/APC interface. Ideal for AI computing clusters, high-density spine-leaf fabrics, campus data center interconnects (DCI), and 400G-to-4x100G breakout connections.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Throughput Parallel SMF:\u003c\/strong\u003e 400Gbps aggregate bandwidth powered by 4×100G PAM4 parallel architecture, bridging short-reach multimode and long-reach CWDM applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersatile Breakout Capability:\u003c\/strong\u003e Supports direct 400G-to-400G links or 400G-to-4×100G DR1\/FR1 breakout cabling to optimize port density.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHost Coding:\u003c\/strong\u003e Coding available for Cisco, Arista, NVIDIA Mellanox, Juniper, or Dell switches and routers; we check coding for your switch model before you order.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDigital Optical Monitoring (DOM):\u003c\/strong\u003e Comprehensive real-time monitoring of operating temperature, supply voltage, laser bias current, and TX\/RX optical power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width: 35%;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"width: 65%;\"\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \u0026amp; Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e400G QSFP-DD DR4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e400Gbps (4×100G PAM4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eQSFP-DD Type 2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1310nm Parallel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSingle-Mode Fiber (SMF, OS2 \/ G.652)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500m\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMPO-12\/APC (MTP-12 APC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModulation Scheme\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4×100G-PAM4 (Electrical \u0026amp; Optical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e≤10W (Typical low-power thermal design)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.3V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransmitter \u0026amp; Detector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEML \/ SiPh Transmitter \u0026amp; PIN Receiver\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCMIS 4.0 \/ CMIS 5.0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0°C ~ 70°C (32°F ~ 158°F) Commercial Grade\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eQSFP-DD MSA, IEEE 802.3bs 400GBASE-DR4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSupported\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCoding Available For\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCisco, Arista, NVIDIA Mellanox, Juniper, Dell\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e400G Single-Mode vs Multimode Architecture Comparison\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse; margin-top: 10px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f7f7f7;\"\u003e\n      \u003cth\u003eFeature\u003c\/th\u003e\n      \u003cth\u003e400G QSFP-DD DR4 (This Model)\u003c\/th\u003e\n      \u003cth\u003e400G QSFP-DD FR4\u003c\/th\u003e\n      \u003cth\u003e400G QSFP-DD SR4\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax Distance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500m\u003c\/td\u003e\n      \u003ctd\u003e2km\u003c\/td\u003e\n      \u003ctd\u003e100m (OM4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOptical Medium\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSingle-Mode (SMF)\u003c\/td\u003e\n      \u003ctd\u003eSingle-Mode (SMF)\u003c\/td\u003e\n      \u003ctd\u003eMultimode (MMF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOptical Scheme\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4×100G Parallel (1310nm)\u003c\/td\u003e\n      \u003ctd\u003eCWDM4 Multiplexing (1271-1331nm)\u003c\/td\u003e\n      \u003ctd\u003e4×100G Parallel (850nm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n      \u003ctd\u003eLC Duplex\u003c\/td\u003e\n      \u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBreakout Support\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eYes (4×100G DR1\/FR1)\u003c\/td\u003e\n      \u003ctd\u003eNo (WDM Multiplexed)\u003c\/td\u003e\n      \u003ctd\u003eYes (4×100G SR1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePrimary Application\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSpine-Leaf \u0026amp; High-Density Breakout\u003c\/td\u003e\n      \u003ctd\u003eLonger Campus DCI Backbone\u003c\/td\u003e\n      \u003ctd\u003eIntra-Rack Server-to-TOR\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eQuality Assurance \u0026amp; Testing\u003c\/h3\u003e\n\u003cp\u003eEach module is tested before dispatch. Our test process includes 3D end-face interferometry, optical eye-diagram checks, bit error rate checks, and switch port link testing. Ask us for test records for this SKU. Engineering support is available when you inquire.\u003c\/p\u003e\n\n\u003ch3\u003eCustom Coding \u0026amp; Sample Inquiries\u003c\/h3\u003e\n\u003cp\u003eWe provide custom EEPROM coding for Cisco, Arista, NVIDIA Mellanox, Juniper, or Dell hosts. Compatibility depends on the host platform. Please share your switch model, software version, module type, link distance and fiber type so we can check coding and compatibility before you order. YYGL Optical is an independent optics supplier; we are not those brands and we do not claim affiliation with them. For volume pricing, project sample requests, or custom cabling configurations, please submit an inquiry or contact our engineering sales team.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions \u0026amp; Interoperability\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does YYGL Optical ensure 400G QSFP-DD transceiver compatibility with Cisco Nexus 9000 and Arista switches?\u003c\/strong\u003e\u003cbr\u003e\nA: YYGL Optical programs custom EEPROM vendor coding into each 400G QSFP-DD module to ensure non-alarm recognition on Cisco Nexus 9300\/9400 series (supporting service unsupported-transceiver bypass when required) and Arista EOS hosts. Built with high-reliability COB packaging, our 400G modules deliver lower thermal resistance and typical power consumption under 10W.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does YYGL Optical support custom EEPROM programming for mixed-vendor data center architectures?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes. Because modern hyperscale fabrics frequently deploy mixed switch platforms, our engineering team offers bespoke firmware flashing for multi-vendor environments, allowing seamless link establishment across disparate spine-leaf tiers.\u003c\/p\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092801077332,"sku":"YY-QSFPDD-DR4-500M","price":314.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/400g-dr4-qsfpdd.jpg?v=1793931403"},{"product_id":"400g-osfp-sr8-pam4-850nm-100m-dom-dual-mpo-12-apc-multimode-optical-module","title":"YYGL 400G OSFP SR8 850nm 100m MPO-16 Multimode Optical Transceiver","description":"\u003ch2\u003e400G OSFP SR8 Multimode Optical Module | PAM4 | 850nm | 100m | DOM | Single MPO-16\/APC\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 400G OSFP SR8\u003c\/strong\u003e optical module is purpose-built for hyperscale data centers and high-density AI computing clusters. Utilizing PAM4 modulation with an \u003cstrong\u003e8×50G\u003c\/strong\u003e parallel channel architecture, it supports a maximum transmission distance of \u003cstrong\u003e100 meters\u003c\/strong\u003e over OM4 multimode fiber.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Bandwidth:\u003c\/strong\u003e 400Gbps aggregate bandwidth via 8×50G PAM4 parallel channels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePAM4 Modulation:\u003c\/strong\u003e Efficient multimode fiber utilization with low latency.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDigital Optical Monitoring (DOM):\u003c\/strong\u003e Real-time telemetry for laser bias, temperature, and power.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e850nm Wavelength:\u003c\/strong\u003e Compatible with OM3\/OM4 multimode fiber infrastructure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSingle MPO-16\/APC Interface:\u003c\/strong\u003e High-density parallel optical connectivity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Consumes ≤9W for optimal rack thermal management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; background-color: #f4f6f8; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; background-color: #f4f6f8; text-align: left;\"\u003eValue \/ Parameter\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eYY-OSFP-SR8-100M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e400Gbps (8×50Gbps PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eOSFP\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Transmitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e8-Channel VCSEL Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003ePIN Photodetector Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eMultimode OM3\/OM4 (MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eMaximum Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e100m over OM4 \/ 70m over OM3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eSingle MPO-16\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e≤9W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e3.3V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e0°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eCMIS Rev 5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eStandards \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eOSFP MSA, IEEE 802.3db\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eDigital Diagnostics (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eHost Coding Available For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eCisco, Arista, NVIDIA Mellanox, Juniper, Dell\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eCompliance Documents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eAvailable per SKU on request\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHost Coding \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003eEach module is tested on host hardware prior to dispatch. Pre-coded for Cisco, Arista, NVIDIA Mellanox, Juniper, and Dell switches.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is the difference between OSFP SR8 and QSFP-DD SR4?\u003c\/h4\u003e\n\u003cp\u003eOSFP SR8 uses an 8x50G electrical and optical architecture with MPO-16, whereas SR4 uses 4x100G with MPO-12.\u003c\/p\u003e\n\u003ch4\u003eWhat is the typical power consumption?\u003c\/h4\u003e\n\u003cp\u003ePower consumption is exceptionally low at ≤9W.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eOrdering \u0026amp; RFQ Information\u003c\/h3\u003e\n\u003cp\u003eContact YYGL Optical for wholesale pricing, sample requests, and technical datasheets.\u003c\/p\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092801110100,"sku":"YY-OSFP-SR8-400G-100M","price":369.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/1_799ac29d-976c-4c77-b421-b79b75750ed7.jpg?v=1781763124"},{"product_id":"400g-qsfp-dd-sr4-plus-pam4-850nm-mma4z00-ns400-dom-mpo-multimode-optical-module","title":"YYGL 400G QSFP-DD SR4+ 850nm 100m MPO-12 Multimode Optical Transceiver","description":"\u003ch2\u003e400G QSFP-DD SR4+ Multimode Optical Module | PAM4 | 850nm | DOM | MPO | MMA4Z00-NS400 Compatible\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 400G QSFP-DD SR4+\u003c\/strong\u003e optical module is an enhanced short-reach multimode solution designed for hyperscale data centers and AI computing clusters. Compatible with the \u003cstrong\u003eMMA4Z00-NS400\u003c\/strong\u003e specification, it delivers \u003cstrong\u003e400Gbps\u003c\/strong\u003e aggregate bandwidth via PAM4 modulation over OM4 multimode fiber.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Short-Reach Performance:\u003c\/strong\u003e Extended reach over OM4 multimode fiber compared to standard SR4.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePAM4 Modulation:\u003c\/strong\u003e 4×100G PAM4 parallel architecture for efficient fiber utilization.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMMA4Z00-NS400 Compatible:\u003c\/strong\u003e Pre-coded for seamless plug-and-play in NVIDIA Mellanox environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDigital Optical Monitoring (DOM):\u003c\/strong\u003e Real-time monitoring of temperature, voltage, and optical power.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPO-12 Interface:\u003c\/strong\u003e Standard parallel fiber interface for high-density cabling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Consumes ≤8.5W.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; background-color: #f4f6f8; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; background-color: #f4f6f8; text-align: left;\"\u003eValue \/ Parameter\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eYY-QSFPDD-SR4PLUS-100M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e400Gbps (4×100Gbps PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eQSFP-DD\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Transmitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eVCSEL Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003ePIN Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eMultimode OM3\/OM4 (MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eMaximum Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e100m over OM4\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eMPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e≤8.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e0°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eStandards \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eQSFP-DD MSA, CMIS Rev 5.2, MMA4Z00-NS400 Compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eDigital Diagnostics (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eHost Coding Available For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eNVIDIA Mellanox, Cisco, Arista, Juniper, Dell\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003e\u003cstrong\u003eCompliance Documents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #d3dbe2;\"\u003eAvailable per SKU on request\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHost Coding \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003eSpecifically verified for NVIDIA Mellanox Quantum \/ Spectrum series switches as an alternative to MMA4Z00-NS400.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eIs this transceiver a compatible replacement for NVIDIA MMA4Z00-NS400?\u003c\/h4\u003e\n\u003cp\u003eYes, it is fully tested and pre-coded to operate seamlessly in NVIDIA Mellanox switch environments without error warnings.\u003c\/p\u003e\n\u003ch4\u003eWhat fiber connector does it use?\u003c\/h4\u003e\n\u003cp\u003eIt uses standard MPO-12\/APC multimode optical connectors.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eOrdering \u0026amp; RFQ Information\u003c\/h3\u003e\n\u003cp\u003eContact our technical sales team for wholesale pricing, compatibility confirmation, and sample orders.\u003c\/p\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092801142868,"sku":"YY-QSFPDD-SR4P-100M","price":314.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/400g-sr4-plus-qsfpdd.jpg?v=1793931408"},{"product_id":"yiyuan-400g-qsfp112-vr4-850nm-50m-mpo-12-multimode-optical-transceiver","title":"YYGL 400G QSFP112 VR4 850nm 50m MPO-12 Multimode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 400G QSFP112 VR4 850nm 50m MPO-12 Multimode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 400G QSFP112 VR4\u003c\/strong\u003e is a next-generation 400Gbps multimode optical transceiver engineered for high-density AI compute clusters, GPU fabrics, and hyperscale data center interconnects (DCI). Utilizing advanced 4-channel 100G PAM4 (4x100G-PAM4) electrical and optical lanes with high-speed VCSEL transmitters, it delivers 400Gbps aggregate throughput over OM4 multimode fiber up to 50 meters with ultra-low latency and maximum power dissipation strictly controlled under 9W.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNative 112Gbps SerDes Architecture:\u003c\/strong\u003e Designed for modern switch silicon with 100G\/lane electrical interfaces (4×106.25Gbps PAM4), eliminating power-hungry gearbox DSP latency.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUltra-Low Power Consumption:\u003c\/strong\u003e Maximum power consumption strictly ≤9W, significantly easing thermal dissipation requirements in high-density 1RU\/2RU switch chassis.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Density Optical Interface:\u003c\/strong\u003e MPO-12\/APC optical connector supporting short-reach intra-rack and row-level spine-leaf topologies.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Telemetry \u0026amp; DOM:\u003c\/strong\u003e Fully compliant with CMIS Rev 5.2 with digital optical monitoring (DOM\/DDM) for real-time monitoring of laser bias, temperature, supply voltage, Tx power, and Rx optical power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-QSFP112-VR4-50M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400Gbps (4×100G PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP112 MSA Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultimode Fiber (OM3 \/ OM4 MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Transmission Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50m over OM4 \/ 30m over OM3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel 850nm VCSEL Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReceiver Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel PIN Photodetector Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4×100G PAM4 (Electrical \u0026amp; Optical)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤9.0W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCMIS Rev 5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP112 MSA, IEEE 802.3db, RoHS-6, CE, Class 1 Laser Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (Real-time I2C Diagnostics)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Lab Validation\u003c\/h3\u003e\n\u003cp\u003eEvery YYGL Optical 400G QSFP112 VR4 module undergoes rigorous full-rate bit error rate testing (BER \u0026lt; 1E-12) and optical eye pattern validation on high-bandwidth digital sampling oscilloscopes before shipment. Custom EEPROM microcode programming is available for seamless integration with major switch and router platforms, including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco:\u003c\/strong\u003e Nexus 9000 Series spine-leaf switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista:\u003c\/strong\u003e 7060X and 7050X series platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNVIDIA Mellanox:\u003c\/strong\u003e Quantum-2 InfiniBand and Spectrum Ethernet switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper Networks:\u003c\/strong\u003e QFX and PTX series routers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell Technologies:\u003c\/strong\u003e PowerSwitch Z-series data center switches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: YYGL Optical is an independent manufacturer. Switch brand names are listed solely for hardware interoperability verification.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003eTypical Deployment Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAI Accelerator Interconnect:\u003c\/strong\u003e Direct connection between GPU servers (e.g., NVIDIA HGX\/DGX) and top-of-rack (TOR) switches where short reach (≤50m) and ultra-low latency are essential for distributed machine learning training fabrics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCloud Spine-Leaf Tier:\u003c\/strong\u003e High-density intra-suite aggregation links in modern hyperscale cloud data centers leveraging OM4 structured trunk cabling.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is the difference between QSFP112 and QSFP-DD in 400G optics?\u003c\/h4\u003e\n\u003cp\u003eQSFP112 utilizes 4 electrical lanes running at 100Gbps PAM4 (112G SerDes), matching modern switch silicon directly without needing an internal 8x50G to 4x100G reverse-gearbox DSP. This reduces latency, lowers power consumption (≤9W vs ~12W), and simplifies thermal design compared to older 8-lane QSFP-DD modules.\u003c\/p\u003e\n\n\u003ch4\u003eWhat cabling and connector does the YYGL 400G QSFP112 VR4 require?\u003c\/h4\u003e\n\u003cp\u003eIt requires an MPO-12\/APC multimode fiber patch cable (OM4 recommended for full 50m reach, OM3 for up to 30m). An APC (Angled Physical Contact) polish is required to minimize optical return loss.\u003c\/p\u003e\n\n\u003ch4\u003eCan this module be coded for specific switch vendors?\u003c\/h4\u003e\n\u003cp\u003eYes. YYGL Optical provides customized vendor EEPROM coding for Cisco, Arista, NVIDIA Mellanox, Juniper, and Dell switches. Please provide your switch model and operating system version when requesting an evaluation sample.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Evaluation \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eEngineering sample units and full laboratory test reports (including eye diagrams and BER logs) are available for customer validation. Contact our technical team for volume pricing and compatibility checks.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is the difference between QSFP112 and QSFP-DD in 400G optics?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"QSFP112 utilizes 4 electrical lanes running at 100Gbps PAM4 (112G SerDes), matching modern switch silicon directly without needing an internal 8x50G to 4x100G reverse-gearbox DSP. This reduces latency, lowers power consumption (≤9W vs ~12W), and simplifies thermal design compared to older 8-lane QSFP-DD modules.\"}},{\"@type\":\"Question\",\"name\":\"What cabling and connector does the YYGL 400G QSFP112 VR4 require?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It requires an MPO-12\/APC multimode fiber patch cable (OM4 recommended for full 50m reach, OM3 for up to 30m). An APC (Angled Physical Contact) polish is required to minimize optical return loss.\"}},{\"@type\":\"Question\",\"name\":\"Can this module be coded for specific switch vendors?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. YYGL Optical provides customized vendor EEPROM coding for Cisco, Arista, NVIDIA Mellanox, Juniper, and Dell switches. Please provide your switch model and operating system version when requesting an evaluation sample.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097290027092,"sku":"YY-QSFP112-VR4-50M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/400g-qsfp112-dr4-plus-1.png?v=1795224802"},{"product_id":"yiyuan-400g-qsfp-dd-vr4-850nm-50m-mpo-12-multimode-optical-transceiver","title":"YYGL 400G QSFP-DD VR4 850nm 50m MPO-12 Multimode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 400G QSFP-DD VR4 850nm 50m MPO-12 Multimode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 400G QSFP-DD VR4\u003c\/strong\u003e is a cost-effective 400Gbps multimode optical transceiver designed for enterprise cloud data centers, high-performance computing (HPC) clusters, and top-of-rack (TOR) server interconnects. Operating over 850nm VCSEL arrays, it provides up to 50 meters transmission distance over OM4 multimode fiber via an MPO-12\/APC connector with comprehensive CMIS digital diagnostics.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBroad QSFP-DD Backward Compatibility:\u003c\/strong\u003e Electrical interface supports 8x50G PAM4 host channels, providing seamless plug-and-play operation in existing QSFP-DD switch ports across enterprise data centers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Energy Efficiency:\u003c\/strong\u003e Power consumption is strictly contained at ≤8.0W, reducing total cooling costs in high-density rack deployments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort-Reach Cost Optimization:\u003c\/strong\u003e Optimized for links up to 50m (OM4), offering a highly economical alternative to longer-reach SR4 optics for server-to-switch connectivity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReal-Time Digital Diagnostics (DOM):\u003c\/strong\u003e Built-in CMIS 5.2 compliant telemetry for active monitoring of transceiver temperature, supply voltage, Tx laser bias, and Rx optical power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-QDD-VR4-50M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400Gbps Aggregate Throughput\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP-DD (Double Density) MSA Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultimode Fiber (OM3 \/ OM4 MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50m over OM4 \/ 30m over OM3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter \/ Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850nm VCSEL Array \/ PIN Photodetector Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8×50Gbps PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4×100Gbps PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤8.0W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCMIS Rev 5.2 \/ Rev 4.0\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP-DD MSA, IEEE 802.3db, RoHS-6, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (Real-time telemetry via I2C)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Lab Validation\u003c\/h3\u003e\n\u003cp\u003eEach transceiver is tested for bit error rate (BER \u0026lt; 1E-12) and eye diagram compliance on calibrated test benches. Custom EEPROM microcode is programmed and verified for compatibility with:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco Systems:\u003c\/strong\u003e Nexus 9300 \/ 9500 400G series.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista Networks:\u003c\/strong\u003e 7060DX and 7280R3 series switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNVIDIA Mellanox:\u003c\/strong\u003e SN4700 \/ SN3700 Spectrum Ethernet platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper Networks:\u003c\/strong\u003e QFX5220 and PTX10000 series.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell Technologies:\u003c\/strong\u003e Z9332F-ON and enterprise PowerSwitch series.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDeployment Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTop-of-Rack (TOR) to Spine Links:\u003c\/strong\u003e Ideal for modern leaf-spine data centers where link distances within the data hall or between adjacent racks do not exceed 50 meters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Performance Compute (HPC) Clusters:\u003c\/strong\u003e Provides low-latency, high-throughput interconnects between GPU\/compute nodes and local leaf switches.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eHow does 400G VR4 differ from 400G SR4?\u003c\/h4\u003e\n\u003cp\u003eVR4 is optimized for up to 50m reach over OM4 multimode fiber, whereas SR4 is rated for up to 100m. VR4 optics utilize optimized VCSEL components that offer lower power consumption (≤8W) and lower procurement cost, making them ideal for intra-rack or short-row connections where 100m reach is unnecessary.\u003c\/p\u003e\n\n\u003ch4\u003eWhat optical patch cord is needed for 400G QSFP-DD VR4?\u003c\/h4\u003e\n\u003cp\u003eA standard 8-fiber or 12-fiber MPO-12\/APC multimode (OM3 or OM4) patch cable is required. APC (Angled Physical Contact) polish is necessary to maintain proper optical return loss.\u003c\/p\u003e\n\n\u003ch4\u003eCan I request custom switch coding before delivery?\u003c\/h4\u003e\n\u003cp\u003eYes. YYGL Optical encodes each order to match your switch environment (Cisco, Arista, NVIDIA, etc.) to ensure seamless recognition and zero compatibility warning flags.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Evaluation \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eEvaluation samples and batch optical test reports are available upon request. Contact our sales engineering team to verify switch model compatibility or discuss volume pricing.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"How does 400G VR4 differ from 400G SR4?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"VR4 is optimized for up to 50m reach over OM4 multimode fiber, whereas SR4 is rated for up to 100m. VR4 optics utilize optimized VCSEL components that offer lower power consumption (≤8W) and lower procurement cost, making them ideal for intra-rack or short-row connections where 100m reach is unnecessary.\"}},{\"@type\":\"Question\",\"name\":\"What optical patch cord is needed for 400G QSFP-DD VR4?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A standard 8-fiber or 12-fiber MPO-12\/APC multimode (OM3 or OM4) patch cable is required. APC (Angled Physical Contact) polish is necessary to maintain proper optical return loss.\"}},{\"@type\":\"Question\",\"name\":\"Can I request custom switch coding before delivery?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. YYGL Optical encodes each order to match your switch environment (Cisco, Arista, NVIDIA, etc.) to ensure seamless recognition and zero compatibility warning flags.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097290092628,"sku":"YY-QSFPDD-VR4-50M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/3_121cd592-ea23-49d4-a6b2-a45146e21fef.jpg?v=1781762389"},{"product_id":"yiyuan-400g-osfp-rhs-dr4-1310nm-500m-mpo-12-single-mode-optical-transceiver","title":"YYGL 400G OSFP-RHS DR4 1310nm 500m MPO-12 Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 400G OSFP-RHS DR4 1310nm 500m MPO-12 Single-Mode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 400G OSFP-RHS DR4\u003c\/strong\u003e is a high-density, low-power single-mode optical transceiver designed for AI infrastructure clusters, hyperscale cloud data center leaf-to-spine fabrics, and 4x100G breakout connections. Packaged in the compact OSFP-RHS (Riding Heat Sink) form factor, it delivers 400Gbps transmission up to 500 meters over standard single-mode fiber (SMF) via an MPO-12\/APC connector.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOSFP-RHS Compact Form Factor:\u003c\/strong\u003e Engineered for high-density compute platforms and AI network switches with integrated Riding Heat Sink (RHS) thermal design.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSingle-Mode Parallel Optics:\u003c\/strong\u003e Operates at 1310nm uncooled EML \/ Silicon Photonics (SiPh) over standard G.652 single-mode fiber up to 500 meters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersatile 400G to 4x100G Breakout:\u003c\/strong\u003e Supports 400Gbps aggregation as well as direct optical breakout to four 100G DR \/ 100G-PAM4 QSFP28\/SFP-DD optical modules using an MPO-to-4xLC breakout cable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStrict Power Budget:\u003c\/strong\u003e Designed for demanding thermal environments, keeping maximum power consumption below 10.0W.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCMIS 5.2 Digital Diagnostics:\u003c\/strong\u003e Full digital optical monitoring (DOM) over I2C interface for real-time laser bias, temperature, supply voltage, and Tx\/Rx optical power levels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-OSFP-RHS-DR4-500M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400Gbps (4×100G PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSFP-RHS (Riding Heat Sink) MSA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1310nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode Fiber (OS2 \/ G.652 SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500m\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC (Parallel Single-Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel 1310nm Silicon Photonics (SiPh) \/ EML\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReceiver Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel PIN Photodetector\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤10.0W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCMIS Rev 5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSFP MSA, IEEE 802.3bs, IEEE 802.3ck, RoHS-6, CE, Class 1 Laser\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (Real-time I2C Diagnostics)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Lab Validation\u003c\/h3\u003e\n\u003cp\u003eEach module is verified on live switch test beds for 100% interoperability and bit error rate performance (BER \u0026lt; 1E-12). Pre-coded firmware is available for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNVIDIA Mellanox:\u003c\/strong\u003e Quantum-2 InfiniBand and Spectrum-3\/Spectrum-4 Ethernet switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista Networks:\u003c\/strong\u003e 7060X series OSFP-RHS platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco Systems:\u003c\/strong\u003e Nexus 9000 cloud switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper Networks:\u003c\/strong\u003e High-density PTX and QFX platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell Technologies:\u003c\/strong\u003e High-density PowerSwitch systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTarget Application Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAI Spine-Leaf Infrastructure:\u003c\/strong\u003e Ideal for interconnecting AI server pods equipped with OSFP-RHS network interface cards (NICs) to spine-leaf switch tiers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4x100G Optical Breakout:\u003c\/strong\u003e Connects a single 400G OSFP-RHS port directly to four distinct 100G DR1 single-mode ports across legacy 100G switches, preserving cabling investment.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is OSFP-RHS and is it compatible with standard OSFP ports?\u003c\/h4\u003e\n\u003cp\u003eOSFP-RHS (Riding Heat Sink) is a standardized, more compact variant of the OSFP form factor where the heat sink is mounted on the switch cage rather than permanently bonded to the transceiver module. OSFP-RHS modules must be plugged into dedicated OSFP-RHS cages, which are commonly found on NVIDIA Mellanox and modern high-density AI platforms.\u003c\/p\u003e\n\n\u003ch4\u003eCan this transceiver break out to four 100G links?\u003c\/h4\u003e\n\u003cp\u003eYes. The 400G DR4 optical architecture uses 4 parallel single-mode fiber pairs. Using an MPO-12\/APC to 4x Duplex LC breakout single-mode cable, you can connect this module to four 100G DR \/ 100G-PAM4 transceivers.\u003c\/p\u003e\n\n\u003ch4\u003eWhat optical connector polish is required?\u003c\/h4\u003e\n\u003cp\u003eMPO-12\/APC (Angled Physical Contact, 8-degree angle) polish is strictly required. Never connect flat UPC connectors to APC interfaces, as it causes severe optical back-reflection and potential connector damage.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Requests \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eEvaluation samples with full optical test reports and EEPROM verification logs are available. Contact YYGL Optical technical sales for project quotations and lead time confirmations.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is OSFP-RHS and is it compatible with standard OSFP ports?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"OSFP-RHS (Riding Heat Sink) is a standardized, more compact variant of the OSFP form factor where the heat sink is mounted on the switch cage rather than permanently bonded to the transceiver module. OSFP-RHS modules must be plugged into dedicated OSFP-RHS cages, which are commonly found on NVIDIA Mellanox and modern high-density AI platforms.\"}},{\"@type\":\"Question\",\"name\":\"Can this transceiver break out to four 100G links?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. The 400G DR4 optical architecture uses 4 parallel single-mode fiber pairs. Using an MPO-12\/APC to 4x Duplex LC breakout single-mode cable, you can connect this module to four 100G DR \/ 100G-PAM4 transceivers.\"}},{\"@type\":\"Question\",\"name\":\"What optical connector polish is required?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"MPO-12\/APC (Angled Physical Contact, 8-degree angle) polish is strictly required. Never connect flat UPC connectors to APC interfaces, as it causes severe optical back-reflection and potential connector damage.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097290158164,"sku":"YY-OSFP-RHS-DR4-500M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/1_799ac29d-976c-4c77-b421-b79b75750ed7.jpg?v=1781763124"},{"product_id":"yiyuan-400g-qsfp-dd-sr8-850nm-100m-mpo-16-multimode-optical-transceiver","title":"YYGL 400G QSFP-DD SR8 850nm 100m MPO-16 Multimode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 400G QSFP-DD SR8 850nm 100m MPO-16 Multimode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 400G QSFP-DD SR8\u003c\/strong\u003e is a high-bandwidth 8-channel optical transceiver designed for enterprise cloud data centers, high-performance computing (HPC), and 400G to 2x200G breakout network architectures. Operating at 850nm over OM4 multimode fiber via an MPO-16\/APC connector, it provides up to 100 meters reach with robust signal integrity and digital optical monitoring.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e8×50G PAM4 Optical Architecture:\u003c\/strong\u003e Features an 8-channel VCSEL transmitter array operating at 53.125Gbps PAM4 per lane, perfectly matched to 50G SerDes switch architectures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible 2×200G or 8×50G Breakout:\u003c\/strong\u003e Supports high-density 400G trunk links or optical breakout to two 200G SR4 modules or eight 50G optical links via structured MPO-16 cabling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended Multimode Reach:\u003c\/strong\u003e Delivers up to 100 meters over OM4 multimode fiber (70 meters over OM3), meeting all intra-data center inter-rack connectivity needs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive CMIS Telemetry:\u003c\/strong\u003e Supports CMIS management interface with real-time DOM monitoring of laser bias, temperature, supply voltage, and Tx\/Rx power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-QDD-SR8-100M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400Gbps (8×50G PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP-DD Type 2 MSA Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultimode Fiber (OM3 \/ OM4 MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100m over OM4 \/ 70m over OM3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-16\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter \/ Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8-Channel 850nm VCSEL Array \/ PIN Photodetector Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤10.0W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCMIS Rev 5.2 \/ Rev 4.0\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP-DD MSA, IEEE 802.3cm, IEEE 802.3cd, RoHS-6, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (Real-time I2C Diagnostics)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Lab Validation\u003c\/h3\u003e\n\u003cp\u003eEach module is tested for low bit error rate (BER \u0026lt; 1E-12) and eye pattern margin on high-speed digital sampling oscilloscopes. Pre-coded EEPROM configurations are available for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco:\u003c\/strong\u003e Nexus 9300 and 9500 modular switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista:\u003c\/strong\u003e 7060X and 7280R series platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNVIDIA Mellanox:\u003c\/strong\u003e Spectrum Ethernet switch platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper:\u003c\/strong\u003e QFX5200 and PTX series routers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell:\u003c\/strong\u003e PowerSwitch data center series.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTypical Deployment Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSpine-to-Leaf Aggregation:\u003c\/strong\u003e High-density 400Gbps uplink connectivity in enterprise data centers using existing MPO-16 multimode trunk cabling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2x200G Breakout Links:\u003c\/strong\u003e Connecting a 400G switch port to two 200G QSFP56 SR4 switch ports using an MPO-16 to 2x MPO-12 breakout cable.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhy does the 400G QSFP-DD SR8 use an MPO-16 connector instead of MPO-12?\u003c\/h4\u003e\n\u003cp\u003eBecause the SR8 architecture uses 8 optical transmit lanes and 8 optical receive lanes (total 16 fibers), it requires a 16-fiber MPO-16\/APC connector. MPO-12 connectors only support up to 4 bi-directional lanes (8 active fibers).\u003c\/p\u003e\n\n\u003ch4\u003eCan this module interoperate with 200G QSFP56 SR4 transceivers?\u003c\/h4\u003e\n\u003cp\u003eYes. By using an MPO-16\/APC to 2x MPO-12\/APC breakout cable, this 400G SR8 module can split into two 200G SR4 links (each running 4x50G PAM4), facilitating phased network upgrades.\u003c\/p\u003e\n\n\u003ch4\u003eIs digital optical monitoring (DOM) supported?\u003c\/h4\u003e\n\u003cp\u003eYes. Full real-time DOM telemetry is supported over the I2C management interface per CMIS specifications, allowing network operators to continuously track laser health and optical link quality.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Evaluation \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eLab evaluation samples and custom vendor coding are available upon request. Contact YYGL Optical for enterprise pricing and availability.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Why does the 400G QSFP-DD SR8 use an MPO-16 connector instead of MPO-12?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Because the SR8 architecture uses 8 optical transmit lanes and 8 optical receive lanes (total 16 fibers), it requires a 16-fiber MPO-16\/APC connector. MPO-12 connectors only support up to 4 bi-directional lanes (8 active fibers).\"}},{\"@type\":\"Question\",\"name\":\"Can this module interoperate with 200G QSFP56 SR4 transceivers?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. By using an MPO-16\/APC to 2x MPO-12\/APC breakout cable, this 400G SR8 module can split into two 200G SR4 links (each running 4x50G PAM4), facilitating phased network upgrades.\"}},{\"@type\":\"Question\",\"name\":\"Is digital optical monitoring (DOM) supported?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Full real-time DOM telemetry is supported over the I2C management interface per CMIS specifications, allowing network operators to continuously track laser health and optical link quality.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097290223700,"sku":"YY-QSFPDD-SR8-400G-100M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/400g-qsfp-dd-sr4-1.png?v=1795224801"},{"product_id":"yiyuan-400g-osfp-rhs-vr4-850nm-50m-mpo-12-multimode-optical-transceiver","title":"YYGL 400G OSFP-RHS VR4 850nm 50m MPO-12 Multimode Optical Transceiver","description":"\u003ch2\u003eYYGL 400G OSFP-RHS VR4 850nm 50m MPO-12 Multimode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 400G OSFP-RHS VR4\u003c\/strong\u003e is a 400G OSFP-RHS multimode optical transceiver operating at 850nm, supporting transmission distances of 30m (OM3) \/ 50m (OM4) over multimode fiber (MMF) with an MPO-12\/APC connector. It is designed for data center interconnect (DCI) and AI computing cluster networks, with digital optical monitoring (DOM) support.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400G OSFP-RHS VR4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSFP-RHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultimode (MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30m (OM3) \/ 50m (OM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation (Electrical Port)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4x100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation (Optical Port)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4x100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤9W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVCSEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C ~ 70°C (32°F ~ 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSFP MSA, CMIS Rev 5.2, IEEE 802.3db\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDOM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Brands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCisco, Arista, Mellanox, Juniper, Dell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoHS, CE, Class 1 Laser Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097290354772,"sku":"YY-OSFP-RHS-VR4-50M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/1_799ac29d-976c-4c77-b421-b79b75750ed7.jpg?v=1781763124"},{"product_id":"yiyuan-400g-osfp-rhs-sr4-850nm-100m-mpo-12-multimode-optical-transceiver","title":"YYGL 400G OSFP-RHS SR4 850nm 100m MPO-12 Multimode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 400G OSFP-RHS SR4 850nm 100m MPO-12 Multimode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 400G OSFP-RHS SR4\u003c\/strong\u003e is an ultra-low latency, high-density 400Gbps multimode optical transceiver designed for GPU server clusters, AI computing pods, and leaf-to-spine interconnects. Built in the compact OSFP-RHS form factor, it delivers 400Gbps aggregate bandwidth over OM4 multimode fiber up to 100 meters via an MPO-12\/APC connector with power consumption strictly under 9.0W.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEngineered for Modern AI Fabrics:\u003c\/strong\u003e Native 4×100G PAM4 architecture operates directly with 100G\/lane switch silicon and GPU network interface cards without gearbox latency.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact OSFP-RHS Package:\u003c\/strong\u003e Riding Heat Sink form factor ensures optimal thermal dissipation in high-density 1RU\/2RU switch chassis and multi-GPU compute servers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended 100m Multimode Reach:\u003c\/strong\u003e Supports up to 100 meters over OM4 fiber (70m over OM3), perfectly covering all intra-data center row and pod connections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnergy Efficient Operation:\u003c\/strong\u003e Total power dissipation strictly controlled at ≤9.0W, minimizing cooling overhead in dense GPU cluster environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCMIS 5.2 Diagnostics:\u003c\/strong\u003e Real-time digital optical monitoring (DOM) for laser bias current, temperature, supply voltage, and Tx\/Rx optical power levels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-OSFP-RHS-SR4-100M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400Gbps (4×100G PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSFP-RHS (Riding Heat Sink)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultimode Fiber (OM3 \/ OM4 MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100m over OM4 \/ 70m over OM3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter \/ Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel 850nm VCSEL Array \/ PIN Photodetector Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤9.0W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCMIS Rev 5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSFP MSA, IEEE 802.3db, RoHS-6, CE, Class 1 Laser\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (Real-time I2C Diagnostics)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Lab Validation\u003c\/h3\u003e\n\u003cp\u003eEach module is verified for bit error rate (BER \u0026lt; 1E-12) and eye pattern margin on high-speed digital sampling oscilloscopes. Pre-coded EEPROM configurations are available for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNVIDIA Mellanox:\u003c\/strong\u003e Quantum-2 InfiniBand and Spectrum-4 Ethernet switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista Networks:\u003c\/strong\u003e 7060X series OSFP-RHS switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco Systems:\u003c\/strong\u003e Nexus 9000 cloud switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper Networks:\u003c\/strong\u003e QFX and PTX series routers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell Technologies:\u003c\/strong\u003e PowerSwitch data center series.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTarget Application Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGPU Pod Cluster Interconnect:\u003c\/strong\u003e High-density interconnects between NVIDIA HGX\/DGX GPU systems and leaf switches requiring compact OSFP-RHS cages.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntra-Suite Multimode Spine-Leaf:\u003c\/strong\u003e High-bandwidth, low-power aggregation links across compute rows using OM4 structured cabling.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eHow does the OSFP-RHS SR4 compare with OSFP-RHS VR4?\u003c\/h4\u003e\n\u003cp\u003eThe SR4 model is rated for up to 100 meters over OM4 fiber, whereas the VR4 is optimized for up to 50 meters. Choose SR4 when your inter-rack or pod cabling spans beyond 50m.\u003c\/p\u003e\n\n\u003ch4\u003eWhat optical patch cable should be used with this transceiver?\u003c\/h4\u003e\n\u003cp\u003eUse an MPO-12\/APC (Angled Physical Contact) multimode fiber patch cord (OM4 recommended). APC polish is required to ensure optimal optical return loss.\u003c\/p\u003e\n\n\u003ch4\u003eCan this module be coded for specific switch environments?\u003c\/h4\u003e\n\u003cp\u003eYes. YYGL Optical provides pre-coded EEPROM settings tailored for NVIDIA, Arista, Cisco, and Juniper switches to guarantee seamless link bring-up and clean telemetry reporting.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Evaluation \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eEngineering evaluation samples with comprehensive lab test reports are available. Contact YYGL Optical to verify compatibility or request a volume quotation.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"How does the OSFP-RHS SR4 compare with OSFP-RHS VR4?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The SR4 model is rated for up to 100 meters over OM4 fiber, whereas the VR4 is optimized for up to 50 meters. Choose SR4 when your inter-rack or pod cabling spans beyond 50m.\"}},{\"@type\":\"Question\",\"name\":\"What optical patch cable should be used with this transceiver?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Use an MPO-12\/APC (Angled Physical Contact) multimode fiber patch cord (OM4 recommended). APC polish is required to ensure optimal optical return loss.\"}},{\"@type\":\"Question\",\"name\":\"Can this module be coded for specific switch environments?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. YYGL Optical provides pre-coded EEPROM settings tailored for NVIDIA, Arista, Cisco, and Juniper switches to guarantee seamless link bring-up and clean telemetry reporting.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097290485844,"sku":"YY-OSFP-RHS-SR4-100M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/1_799ac29d-976c-4c77-b421-b79b75750ed7.jpg?v=1781763124"},{"product_id":"yiyuan-400g-qsfp112-sr4-850nm-100m-mpo-12-multimode-optical-transceiver","title":"YYGL 400G QSFP112 SR4 850nm 100m MPO-12 Multimode Optical Transceiver","description":"\u003ch2\u003eYYGL 400G QSFP112 SR4 850nm 100m MPO-12 Multimode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 400G QSFP112 SR4\u003c\/strong\u003e is a 400G QSFP112 multimode optical transceiver operating at 850nm, supporting transmission distances of 60m (OM3) \/ 100m (OM4) over multimode fiber (MMF) with an MPO-12\/APC connector. It is designed for data center interconnect (DCI) and AI computing cluster networks, with digital optical monitoring (DOM) support.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400G QSFP112 SR4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultimode (MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60m (OM3) \/ 100m (OM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation (Electrical Port)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4x100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation (Optical Port)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4x100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤9W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVCSEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C ~ 70°C (32°F ~ 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP112 MSA, CMIS Rev 5.2, IEEE 802.3db\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDOM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Brands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCisco, Arista, Mellanox, Juniper, Dell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoHS, CE, Class 1 Laser Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097290780756,"sku":"YY-QSFP112-SR4-100M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/6_65de0842-47dc-4cd7-b1ba-3191e9d8e707.jpg?v=1782886599"},{"product_id":"yiyuan-400g-qsfp112-dr4-1310nm-2km-mpo-12-single-mode-optical-transceiver","title":"YYGL 400G QSFP112 DR4+ 1310nm 2km MPO-12 Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL 400G QSFP112 DR4+ 1310nm 2km MPO-12 Single-Mode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL 400G QSFP112 DR4+\u003c\/strong\u003e is a 400G QSFP112 single-mode optical transceiver operating at 1310nm, supporting transmission distances of 2km over single-mode fiber (SMF) with an MPO-12\/APC connector. It is designed for data center interconnect (DCI) and AI computing cluster networks, with digital optical monitoring (DOM) support.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400G QSFP112 DR4+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1310nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode (SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation (Electrical Port)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4x100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation (Optical Port)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4x100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤9W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiPh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C ~ 70°C (32°F ~ 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP112 MSA, CMIS Rev 5.2, IEEE 802.3bs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDOM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Brands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCisco, Arista, Mellanox, Juniper, Dell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoHS, CE, Class 1 Laser Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097291075668,"sku":"YY-QSFP112-DR4P-2KM","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/400g-qsfp112-dr4-plus-1.png?v=1795224802"},{"product_id":"yiyuan-400g-qsfp112-dr4-1310nm-500m-mpo-12-single-mode-optical-transceiver","title":"YYGL 400G QSFP112 DR4 1310nm 500m MPO-12 Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 400G QSFP112 DR4 1310nm 500m MPO-12 Single-Mode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 400G QSFP112 DR4\u003c\/strong\u003e is a high-performance 400Gbps single-mode optical transceiver designed for next-generation AI compute clusters, hyperscale cloud data centers, and high-density spine-leaf networks. Operating at 1310nm over single-mode fiber (SMF) up to 500 meters via an MPO-12\/APC connector, it utilizes native 112Gbps SerDes electrical interfaces to provide unmatched latency performance and power efficiency below 10.0W.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNative 4×100G PAM4 Architecture:\u003c\/strong\u003e Designed for advanced switch silicon with native 112G SerDes ports, eliminating reverse-gearbox latency and optimizing thermal dissipation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSingle-Mode Parallel Reach:\u003c\/strong\u003e Transmits up to 500 meters over standard OS2 \/ G.652 single-mode fiber (SMF) using high-reliability 1310nm Silicon Photonics (SiPh) \/ EML transmitters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupports 4x100G Breakout:\u003c\/strong\u003e Can be deployed for direct 400G-to-400G connections or broken out into four 100G DR \/ 100G-PAM4 single-mode links via an MPO-to-4xLC breakout cable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStrict Power Control:\u003c\/strong\u003e Maximum power dissipation is strictly contained at ≤10.0W, reducing data center cooling overhead.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCMIS 5.2 Digital Diagnostics:\u003c\/strong\u003e Compliant with Common Management Interface Specification (CMIS) Rev 5.2 for real-time telemetry of temperature, supply voltage, laser bias, and optical power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-QSFP112-DR4-500M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400Gbps (4×100G PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP112 MSA Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1310nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode Fiber (OS2 \/ G.652 SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500m\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC (Parallel Single-Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter \/ Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel 1310nm SiPh\/EML \/ PIN Photodetector Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation Scheme\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4×100G PAM4 (Electrical \u0026amp; Optical)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤10.0W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCMIS Rev 5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP112 MSA, IEEE 802.3cu, IEEE 802.3ck, RoHS-6, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (Real-time I2C Diagnostics)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Lab Validation\u003c\/h3\u003e\n\u003cp\u003eEach transceiver is tested for bit error rate (BER \u0026lt; 1E-12) and optical eye diagram margin on digital sampling oscilloscopes. Pre-coded EEPROM firmware is available for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco:\u003c\/strong\u003e Nexus 9000 series cloud switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista:\u003c\/strong\u003e 7060X series QSFP112 platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNVIDIA Mellanox:\u003c\/strong\u003e Spectrum Ethernet and Quantum-2 switch systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper:\u003c\/strong\u003e High-density PTX and QFX platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell:\u003c\/strong\u003e PowerSwitch data center series.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDeployment Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHyperscale Spine-Leaf Interconnect:\u003c\/strong\u003e High-density 400Gbps single-mode links between leaf and spine switches spanning up to 500 meters across data halls.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptical Breakout to 4x100G:\u003c\/strong\u003e Using an MPO-12\/APC to 4x Duplex LC single-mode cable, this transceiver breaks out seamlessly into four 100G DR optical transceivers.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is the difference between QSFP112 DR4 and QSFP-DD DR4?\u003c\/h4\u003e\n\u003cp\u003eQSFP112 uses 4 electrical lanes running at 100Gbps PAM4, matching 112G SerDes switch chips directly without an internal 8x50G-to-4x100G gearbox DSP. This provides lower latency, lower power consumption, and simpler thermal dissipation than 8-lane QSFP-DD modules.\u003c\/p\u003e\n\n\u003ch4\u003eCan this transceiver interoperate with 100G DR transceivers?\u003c\/h4\u003e\n\u003cp\u003eYes. The optical lane parameters conform to IEEE 802.3cu 100G-DR standards. Using an MPO-12\/APC to 4x LC breakout single-mode cable, each optical lane links directly to an independent 100G DR transceiver.\u003c\/p\u003e\n\n\u003ch4\u003eWhat optical connector is required?\u003c\/h4\u003e\n\u003cp\u003eAn MPO-12\/APC single-mode patch cord (8-degree angled polish) is required. Ensure both ends use APC polish to prevent back-reflection damage.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Evaluation \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eEvaluation samples with full optical test reports and EEPROM verification logs are available. Contact YYGL Optical technical sales for project quotations and lead time confirmations.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is the difference between QSFP112 DR4 and QSFP-DD DR4?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"QSFP112 uses 4 electrical lanes running at 100Gbps PAM4, matching 112G SerDes switch chips directly without an internal 8x50G-to-4x100G gearbox DSP. This provides lower latency, lower power consumption, and simpler thermal dissipation than 8-lane QSFP-DD modules.\"}},{\"@type\":\"Question\",\"name\":\"Can this transceiver interoperate with 100G DR transceivers?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. The optical lane parameters conform to IEEE 802.3cu 100G-DR standards. Using an MPO-12\/APC to 4x LC breakout single-mode cable, each optical lane links directly to an independent 100G DR transceiver.\"}},{\"@type\":\"Question\",\"name\":\"What optical connector is required?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"An MPO-12\/APC single-mode patch cord (8-degree angled polish) is required. Ensure both ends use APC polish to prevent back-reflection damage.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097291305044,"sku":"YY-QSFP112-DR4-500M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/400g-qsfp112-dr4-plus-1.png?v=1795224802"}],"url":"https:\/\/yiyuanguanglink.com\/ja\/collections\/400g-data-center-optics.oembed","provider":"YYGL Optical","version":"1.0","type":"link"}