{"product_id":"10g-sfp-plus-er-1550nm-40km-dom-lc-duplex-single-mode-optical-module-transceiver","title":"YYGL 10G SFP+ ER 1550nm 40km LC Duplex Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 10G SFP+ ER 1550nm 40km LC Duplex Single-Mode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 10G SFP+ ER\u003c\/strong\u003e is a high-performance extended-reach single-mode optical transceiver designed for metropolitan area networks (MAN), regional campus backbones, and data center interconnects (DCI). Operating at the low-attenuation 1550nm optical window over single-mode fiber (SMF), it provides reliable transmission up to \u003cstrong\u003e40 kilometers\u003c\/strong\u003e via standard LC Duplex connectors without needing optical amplifiers.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1550nm Cooled EML Laser:\u003c\/strong\u003e Utilizes an electro-absorption modulated laser (EML) operating at 1550nm where fiber attenuation is minimized (~0.2dB\/km), delivering high dispersion tolerance over 40km links.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Power Link Budget:\u003c\/strong\u003e Designed with an optical power budget exceeding 15dB, ensuring dependable signal integrity across mid-range regional fiber spans.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive SFF-8472 DOM Telemetry:\u003c\/strong\u003e Built-in digital diagnostics provide active monitoring of module temperature, supply voltage, laser bias, and Tx\/Rx optical power levels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnergy Efficient Operation:\u003c\/strong\u003e Total power dissipation strictly controlled at ≤1.5W, compatible with commercial temperature environments (0°C to 70°C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-SFP-ER-40KM\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3125Gbps (10GBASE-ER)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFP+ (Enhanced Small Form-Factor Pluggable)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1550nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode Fiber (OS2 \/ G.652 SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Transmission Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kilometers (24.8 miles)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC Duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter \/ Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1550nm Cooled EML Laser \/ High-Sensitivity PIN Receiver\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFF-8431, SFF-8472, IEEE 802.3ae 10GBASE-ER, RoHS-6, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (SFF-8472 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Lab Validation\u003c\/h3\u003e\n\u003cp\u003eEach module is verified on live switch test beds for bit error rate performance (BER \u0026lt; 1E-12). Pre-coded EEPROM configurations are available for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco:\u003c\/strong\u003e Catalyst, Nexus, and ASR router series.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista Networks:\u003c\/strong\u003e 7050, 7150, and 7280 series.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper Networks:\u003c\/strong\u003e MX and QFX platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell Technologies:\u003c\/strong\u003e PowerSwitch enterprise series.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMikroTik \/ Ubiquiti:\u003c\/strong\u003e Carrier-grade routing platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTarget Application Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMetropolitan Area Networks (MAN):\u003c\/strong\u003e Direct interconnects between enterprise offices or colocation facilities spanning 10km to 40km without optical repeaters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMid-Range DCI:\u003c\/strong\u003e Data center replication and backup transport links across regional campuses.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eHow does 10G SFP+ ER differ from 10G SFP+ LR?\u003c\/h4\u003e\n\u003cp\u003eWhile 10G LR uses a 1310nm laser for distances up to 10km, 10G ER utilizes a cooled 1550nm EML laser capable of bridging up to 40km over standard single-mode fiber, making ER suitable for inter-city and metro-scale networking.\u003c\/p\u003e\n\n\u003ch4\u003eDo I need an optical attenuator when testing 10G ER on short links in a lab?\u003c\/h4\u003e\n\u003cp\u003eYes. Because the 10G ER transmitter outputs significant optical power, testing it back-to-back on a short fiber patch cable (e.g., \u0026lt;10km) requires a 5dB to 10dB optical attenuator to prevent overloading or damaging the optical receiver.\u003c\/p\u003e\n\n\u003ch4\u003eIs digital diagnostics monitoring (DOM) supported?\u003c\/h4\u003e\n\u003cp\u003eYes. Full SFF-8472 compliant DOM telemetry is built into the module, allowing continuous monitoring of laser bias, internal temperature, voltage, and optical power.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Evaluation \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eContact YYGL Optical to request sample units, verify switch hardware compatibility, or discuss bulk pricing for network infrastructure rollouts.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"How does 10G SFP+ ER differ from 10G SFP+ LR?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"While 10G LR uses a 1310nm laser for distances up to 10km, 10G ER utilizes a cooled 1550nm EML laser capable of bridging up to 40km over standard single-mode fiber, making ER suitable for inter-city and metro-scale networking.\"}},{\"@type\":\"Question\",\"name\":\"Do I need an optical attenuator when testing 10G ER on short links in a lab?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Because the 10G ER transmitter outputs significant optical power, testing it back-to-back on a short fiber patch cable (e.g., \u003c10km) requires a 5dB to 10dB optical attenuator to prevent overloading or damaging the optical receiver.\"}},{\"@type\":\"Question\",\"name\":\"Is digital diagnostics monitoring (DOM) supported?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Full SFF-8472 compliant DOM telemetry is built into the module, allowing continuous monitoring of laser bias, internal temperature, voltage, and optical power.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":47092801241172,"sku":"YY-SFP-ER-40KM","price":11.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/10g-sfp-er.jpg?v=1793931399","url":"https:\/\/yiyuanguanglink.com\/ja\/products\/10g-sfp-plus-er-1550nm-40km-dom-lc-duplex-single-mode-optical-module-transceiver","provider":"YYGL Optical","version":"1.0","type":"link"}