{"product_id":"yiyuan-400g-osfp-rhs-dr4-1310nm-500m-mpo-12-single-mode-optical-transceiver","title":"YYGL 400G OSFP-RHS DR4 1310nm 500m MPO-12 Single-Mode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 400G OSFP-RHS DR4 1310nm 500m MPO-12 Single-Mode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 400G OSFP-RHS DR4\u003c\/strong\u003e is a high-density, low-power single-mode optical transceiver designed for AI infrastructure clusters, hyperscale cloud data center leaf-to-spine fabrics, and 4x100G breakout connections. Packaged in the compact OSFP-RHS (Riding Heat Sink) form factor, it delivers 400Gbps transmission up to 500 meters over standard single-mode fiber (SMF) via an MPO-12\/APC connector.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOSFP-RHS Compact Form Factor:\u003c\/strong\u003e Engineered for high-density compute platforms and AI network switches with integrated Riding Heat Sink (RHS) thermal design.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSingle-Mode Parallel Optics:\u003c\/strong\u003e Operates at 1310nm uncooled EML \/ Silicon Photonics (SiPh) over standard G.652 single-mode fiber up to 500 meters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersatile 400G to 4x100G Breakout:\u003c\/strong\u003e Supports 400Gbps aggregation as well as direct optical breakout to four 100G DR \/ 100G-PAM4 QSFP28\/SFP-DD optical modules using an MPO-to-4xLC breakout cable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStrict Power Budget:\u003c\/strong\u003e Designed for demanding thermal environments, keeping maximum power consumption below 10.0W.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCMIS 5.2 Digital Diagnostics:\u003c\/strong\u003e Full digital optical monitoring (DOM) over I2C interface for real-time laser bias, temperature, supply voltage, and Tx\/Rx optical power levels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-OSFP-RHS-DR4-500M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400Gbps (4×100G PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSFP-RHS (Riding Heat Sink) MSA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1310nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode Fiber (OS2 \/ G.652 SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500m\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC (Parallel Single-Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel 1310nm Silicon Photonics (SiPh) \/ EML\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReceiver Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel PIN Photodetector\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤10.0W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCMIS Rev 5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSFP MSA, IEEE 802.3bs, IEEE 802.3ck, RoHS-6, CE, Class 1 Laser\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (Real-time I2C Diagnostics)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Lab Validation\u003c\/h3\u003e\n\u003cp\u003eEach module is verified on live switch test beds for 100% interoperability and bit error rate performance (BER \u0026lt; 1E-12). Pre-coded firmware is available for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNVIDIA Mellanox:\u003c\/strong\u003e Quantum-2 InfiniBand and Spectrum-3\/Spectrum-4 Ethernet switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista Networks:\u003c\/strong\u003e 7060X series OSFP-RHS platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco Systems:\u003c\/strong\u003e Nexus 9000 cloud switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper Networks:\u003c\/strong\u003e High-density PTX and QFX platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell Technologies:\u003c\/strong\u003e High-density PowerSwitch systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTarget Application Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAI Spine-Leaf Infrastructure:\u003c\/strong\u003e Ideal for interconnecting AI server pods equipped with OSFP-RHS network interface cards (NICs) to spine-leaf switch tiers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4x100G Optical Breakout:\u003c\/strong\u003e Connects a single 400G OSFP-RHS port directly to four distinct 100G DR1 single-mode ports across legacy 100G switches, preserving cabling investment.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is OSFP-RHS and is it compatible with standard OSFP ports?\u003c\/h4\u003e\n\u003cp\u003eOSFP-RHS (Riding Heat Sink) is a standardized, more compact variant of the OSFP form factor where the heat sink is mounted on the switch cage rather than permanently bonded to the transceiver module. OSFP-RHS modules must be plugged into dedicated OSFP-RHS cages, which are commonly found on NVIDIA Mellanox and modern high-density AI platforms.\u003c\/p\u003e\n\n\u003ch4\u003eCan this transceiver break out to four 100G links?\u003c\/h4\u003e\n\u003cp\u003eYes. The 400G DR4 optical architecture uses 4 parallel single-mode fiber pairs. Using an MPO-12\/APC to 4x Duplex LC breakout single-mode cable, you can connect this module to four 100G DR \/ 100G-PAM4 transceivers.\u003c\/p\u003e\n\n\u003ch4\u003eWhat optical connector polish is required?\u003c\/h4\u003e\n\u003cp\u003eMPO-12\/APC (Angled Physical Contact, 8-degree angle) polish is strictly required. Never connect flat UPC connectors to APC interfaces, as it causes severe optical back-reflection and potential connector damage.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Requests \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eEvaluation samples with full optical test reports and EEPROM verification logs are available. Contact YYGL Optical technical sales for project quotations and lead time confirmations.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is OSFP-RHS and is it compatible with standard OSFP ports?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"OSFP-RHS (Riding Heat Sink) is a standardized, more compact variant of the OSFP form factor where the heat sink is mounted on the switch cage rather than permanently bonded to the transceiver module. OSFP-RHS modules must be plugged into dedicated OSFP-RHS cages, which are commonly found on NVIDIA Mellanox and modern high-density AI platforms.\"}},{\"@type\":\"Question\",\"name\":\"Can this transceiver break out to four 100G links?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. The 400G DR4 optical architecture uses 4 parallel single-mode fiber pairs. Using an MPO-12\/APC to 4x Duplex LC breakout single-mode cable, you can connect this module to four 100G DR \/ 100G-PAM4 transceivers.\"}},{\"@type\":\"Question\",\"name\":\"What optical connector polish is required?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"MPO-12\/APC (Angled Physical Contact, 8-degree angle) polish is strictly required. Never connect flat UPC connectors to APC interfaces, as it causes severe optical back-reflection and potential connector damage.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097290158164,"sku":"YY-OSFP-RHS-DR4-500M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/1_799ac29d-976c-4c77-b421-b79b75750ed7.jpg?v=1781763124","url":"https:\/\/yiyuanguanglink.com\/ja\/products\/yiyuan-400g-osfp-rhs-dr4-1310nm-500m-mpo-12-single-mode-optical-transceiver","provider":"YYGL Optical","version":"1.0","type":"link"}