{"product_id":"yiyuan-400g-osfp-rhs-sr4-850nm-100m-mpo-12-multimode-optical-transceiver","title":"YYGL 400G OSFP-RHS SR4 850nm 100m MPO-12 Multimode Optical Transceiver","description":"\u003ch2\u003eYYGL Optical 400G OSFP-RHS SR4 850nm 100m MPO-12 Multimode Optical Transceiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYYGL Optical 400G OSFP-RHS SR4\u003c\/strong\u003e is an ultra-low latency, high-density 400Gbps multimode optical transceiver designed for GPU server clusters, AI computing pods, and leaf-to-spine interconnects. Built in the compact OSFP-RHS form factor, it delivers 400Gbps aggregate bandwidth over OM4 multimode fiber up to 100 meters via an MPO-12\/APC connector with power consumption strictly under 9.0W.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Engineering Highlights\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEngineered for Modern AI Fabrics:\u003c\/strong\u003e Native 4×100G PAM4 architecture operates directly with 100G\/lane switch silicon and GPU network interface cards without gearbox latency.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact OSFP-RHS Package:\u003c\/strong\u003e Riding Heat Sink form factor ensures optimal thermal dissipation in high-density 1RU\/2RU switch chassis and multi-GPU compute servers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended 100m Multimode Reach:\u003c\/strong\u003e Supports up to 100 meters over OM4 fiber (70m over OM3), perfectly covering all intra-data center row and pod connections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnergy Efficient Operation:\u003c\/strong\u003e Total power dissipation strictly controlled at ≤9.0W, minimizing cooling overhead in dense GPU cluster environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCMIS 5.2 Diagnostics:\u003c\/strong\u003e Real-time digital optical monitoring (DOM) for laser bias current, temperature, supply voltage, and Tx\/Rx optical power levels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f4f6f8; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 35%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #d3dbe2; width: 65%;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (SKU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYY-OSFP-RHS-SR4-100M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400Gbps (4×100G PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSFP-RHS (Riding Heat Sink)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCentral Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultimode Fiber (OM3 \/ OM4 MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100m over OM4 \/ 70m over OM3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter \/ Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel 850nm VCSEL Array \/ PIN Photodetector Array\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤9.0W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Case Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCMIS Rev 5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOSFP MSA, IEEE 802.3db, RoHS-6, CE, Class 1 Laser\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Optical Monitoring (DOM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (Real-time I2C Diagnostics)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMulti-Vendor Compatibility \u0026amp; Lab Validation\u003c\/h3\u003e\n\u003cp\u003eEach module is verified for bit error rate (BER \u0026lt; 1E-12) and eye pattern margin on high-speed digital sampling oscilloscopes. Pre-coded EEPROM configurations are available for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNVIDIA Mellanox:\u003c\/strong\u003e Quantum-2 InfiniBand and Spectrum-4 Ethernet switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eArista Networks:\u003c\/strong\u003e 7060X series OSFP-RHS switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCisco Systems:\u003c\/strong\u003e Nexus 9000 cloud switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJuniper Networks:\u003c\/strong\u003e QFX and PTX series routers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDell Technologies:\u003c\/strong\u003e PowerSwitch data center series.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTarget Application Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGPU Pod Cluster Interconnect:\u003c\/strong\u003e High-density interconnects between NVIDIA HGX\/DGX GPU systems and leaf switches requiring compact OSFP-RHS cages.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntra-Suite Multimode Spine-Leaf:\u003c\/strong\u003e High-bandwidth, low-power aggregation links across compute rows using OM4 structured cabling.\u003c\/p\u003e\n\n\u003csection id=\"faq\" class=\"yygl-faq\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eHow does the OSFP-RHS SR4 compare with OSFP-RHS VR4?\u003c\/h4\u003e\n\u003cp\u003eThe SR4 model is rated for up to 100 meters over OM4 fiber, whereas the VR4 is optimized for up to 50 meters. Choose SR4 when your inter-rack or pod cabling spans beyond 50m.\u003c\/p\u003e\n\n\u003ch4\u003eWhat optical patch cable should be used with this transceiver?\u003c\/h4\u003e\n\u003cp\u003eUse an MPO-12\/APC (Angled Physical Contact) multimode fiber patch cord (OM4 recommended). APC polish is required to ensure optimal optical return loss.\u003c\/p\u003e\n\n\u003ch4\u003eCan this module be coded for specific switch environments?\u003c\/h4\u003e\n\u003cp\u003eYes. YYGL Optical provides pre-coded EEPROM settings tailored for NVIDIA, Arista, Cisco, and Juniper switches to guarantee seamless link bring-up and clean telemetry reporting.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003eSample Evaluation \u0026amp; RFQ\u003c\/h3\u003e\n\u003cp\u003eEngineering evaluation samples with comprehensive lab test reports are available. Contact YYGL Optical to verify compatibility or request a volume quotation.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"How does the OSFP-RHS SR4 compare with OSFP-RHS VR4?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The SR4 model is rated for up to 100 meters over OM4 fiber, whereas the VR4 is optimized for up to 50 meters. Choose SR4 when your inter-rack or pod cabling spans beyond 50m.\"}},{\"@type\":\"Question\",\"name\":\"What optical patch cable should be used with this transceiver?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Use an MPO-12\/APC (Angled Physical Contact) multimode fiber patch cord (OM4 recommended). APC polish is required to ensure optimal optical return loss.\"}},{\"@type\":\"Question\",\"name\":\"Can this module be coded for specific switch environments?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. YYGL Optical provides pre-coded EEPROM settings tailored for NVIDIA, Arista, Cisco, and Juniper switches to guarantee seamless link bring-up and clean telemetry reporting.\"}}]}\u003c\/script\u003e","brand":"YYGL Optical","offers":[{"title":"Default Title","offer_id":48097290485844,"sku":"YY-OSFP-RHS-SR4-100M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/0901\/4868\/files\/1_799ac29d-976c-4c77-b421-b79b75750ed7.jpg?v=1781763124","url":"https:\/\/yiyuanguanglink.com\/ja\/products\/yiyuan-400g-osfp-rhs-sr4-850nm-100m-mpo-12-multimode-optical-transceiver","provider":"YYGL Optical","version":"1.0","type":"link"}