A “compatible” 1.6T OSFP224 module for AI GPU clusters is one that matches the host’s mechanical variant (including IHS versus RHS), uses the expected CMIS profile, and is qualified on the exact switch or NIC and software you will run. That bar is higher in 2026 because IEEE P802.3dj — the project that defines 1.6 Tb/s Ethernet physical layers — was not yet a published IEEE standard as of October 2026. For 500 m parallel single-mode links, the usual optical class is a 2xDR4 / DR8 1310 nm module with dual MPO-12/APC connectors.

This draft is a compatibility guide, not a “best 1.6T” ranking. A supplier-oriented 1.6T article is already live: What Is the Best 1.6T Optical Transceiver for AI Data Centers in 2026?. The live YYGL catalog, as reviewed for this draft, lists one 1.6T product: a DR4/DR8 500 m single-mode module. It does not list a 1.6T SR8. YYGL Optical is an independent factory-direct supplier and is not NVIDIA, Arista, Cisco, or any other host brand.

What 1.6T OSFP224 means

A 1.6T (1.6 Tb/s) optical transceiver moves 1,600 Gb/s through one module. In the OSFP224 generation that is typically eight electrical lanes of 200G PAM4. The OSFP MSA describes this as OSFP1600 / 1.6TAUI-8 operation: 224G-PAM4 signaling at 106.25 Gbaud per lane, with PMD mappings that can present 1×1.6T, 2×800G, 4×400G, or 8×200G depending on the host. Management is specified separately in CMIS; YYGL’s 1.6T listing names CMIS Rev 5.2.

“OSFP224” in supplier language and “OSFP1600” in the MSA are the same generation of eight 200G-class lanes in the OSFP envelope. The mechanical family still splits into OSFP (integrated heat sink) and OSFP-RHS (riding heat sink). Those two are not compatible. Compatibility starts with the cage, not with the “1.6T” label.

Standards status: why draft compliance is not enough

IEEE Std 802.3df-2024 already covers 800 Gb/s Ethernet. 1.6 Tb/s Ethernet, and 200 Gb/s-per-lane optical and electrical interfaces more broadly, are in IEEE P802.3dj. As of 10 October 2026 the third Standards Association recirculation ballot on P802.3dj Draft 3.3 had closed with a 97% approval rate, and IEEE 802 LMSC had granted conditional approval on 6 October 2026 to submit the draft to RevCom. Task-force meetings after the 14 October 2026 comment-resolution call were cancelled. That is late-stage work, but it is not the same as a published IEEE Std 802.3dj.

The practical consequence for buyers: shipping 1.6T modules may reference draft behavior, vendor implementations, and host qualification rather than a finished, published PMD clause. “802.3dj compliant” on a data sheet is not a substitute for a successful bring-up on your switch or NIC and software. Qualify the module and the host as a pair, and keep firmware versions in the test matrix.

For 1.6T / OSFP224 procurement, the relevant public references are IEEE P802.3dj — the project defining 200 Gb/s-per-lane electrical and optical interfaces for 1.6 Tb/s Ethernet and related 800 Gb/s operation — and the OSFP MSA for the OSFP224 / OSFP1600 mechanical and electrical envelope. Until P802.3dj is published as an IEEE standard, treat those references as the current industry baseline and still require per-platform qualification. This article cites those public sources; it does not treat a product-page compliance row as the definition of the 1.6T class.

Three host patterns you must not mix up

Host pattern What the cage is doing Typical optics shape Compatibility implication
Twin-port 1.6T switch cage (example: NVIDIA Quantum-X800 Q3400-RA, 72 OSFP cages presenting 144×800G XDR) One physical OSFP cage carries two 800G optical ports Twin-port 1600 Gb/s 2xDR4, IHS, dual MPO-12/APC, 1310 nm, 500 m (NVIDIA’s published MMS4A00 is this class; 33.5 W max, CMIS 4.0 on that NVIDIA data sheet) Order an IHS twin-port module of the same optical class, then qualify coding and software. An RHS or single-port 800G module is the wrong mechanical part.
800G NIC or adapter cage in the same cluster (example: ConnectX-8 SuperNIC, single-cage OSFP) One 800G port, often RHS Single-port 800G OSFP RHS, for example NVIDIA’s published 800G DR4 RHS (980-9IAT0 / MMS4A20 class) Do not put the switch’s twin-port IHS 1.6T module into the NIC. Link the two sides with the correct fiber breakout or a documented splitter cable.
Native 1.6T Ethernet port on a 224G-SerDes host One cage is a true 1.6T Ethernet interface A 1.6T OSFP224 module in the heat-sink style that host requires Confirm Ethernet versus InfiniBand, the PMD class, and the software image. A module brought up on an XDR switch is not automatically qualified on an Ethernet 1.6T port.

NVIDIA’s published maxima and CMIS revision for MMS4A00 are included here as industry context, not as YYGL specifications and not as a claim of equivalence. Power, temperature range, and CMIS revision can differ between vendors even when the optical class looks the same. Do not treat a third-party 2xDR4/DR8 module as a drop-in MMS4A00 replacement unless the supplier has confirmed coding and you have piloted that exact pair.

YYGL’s live 1.6T OSFP224 listing

The current catalog page is YYGL 1.6T OSFP224 DR4/DR8, 1310 nm, 500 m (SKU YY-OSFP224-DR4DR8-500M), also listed in the 1.6T collection. The live listing states:

  • 1.6 Tb/s aggregate; 8×200G PAM4 electrical / dual 4×200G PAM4 optical
  • OSFP224 form factor; 1310 nm; 500 m over G.652 single-mode fiber
  • Dual MPO-12/APC (dual MTP-12)
  • Silicon photonics transmitter and PIN receiver; power consumption ≤24 W; 3.3 V DC
  • CMIS 5.2; DOM (temperature, Vcc, Tx bias, Tx/Rx power)
  • Operating case temperature 0 °C to 70 °C
  • Coding available for Cisco, Arista, NVIDIA Mellanox, Juniper, and Dell; checked for your platform before you order
  • Each module is tested before dispatch (the listing names 3D end-face interferometry, eye-diagram checks, bit-error-rate checks, and switch-port link testing). Ask for the test records for this SKU.

The listing does not, in the specification table reviewed for this draft, name an IHS versus RHS variant, a RoHS/CE/Class 1 row, or a warranty term. OSFP modules come in IHS (finned top) or RHS (flat top) variants depending on the host; confirm the variant your switch or NIC needs when ordering, and ask for any certification or warranty terms you need to file, through the RFQ form or yygl@yiyuanguanglian.cn. This article does not present a 1.6T SR8 as a YYGL product: SR8 remains a common industry form factor for short multimode links, but the live YYGL 1.6T catalog SKU linked above is the 500 m single-mode DR4/DR8 module only.

Related 800G single-mode modules for hosts that are still 8×100G, not 8×200G, include the 800G OSFP DR8 500 m and the 800G OSFP DR8+. Those are 800G modules; they are not substitutes for a 1.6T OSFP224 cage.

A compatibility checklist you can put in the RFQ

  1. Host model and fabric family (InfiniBand XDR, Ethernet, or mixed).
  2. Cage variant: OSFP IHS or OSFP-RHS; twin-port versus single-port; airflow direction if the host requires it.
  3. Software or firmware version, including any validated-release name your cluster follows.
  4. Optical class: 2xDR4/DR8, 1310 nm, 500 m, dual MPO-12/APC, unless you have a different plant.
  5. Far-end device: another 1.6T twin-port, two 800G RHS endpoints, or a different PMD. Draw the fiber map before you order.
  6. Written coding confirmation and the test records available for YY-OSFP224-DR4DR8-500M (or the SKU the supplier recommends after the check).
  7. A pilot on the production host and software, with DOM monitored under representative traffic. Re-check after a software change.

For manufacturing context, see the factory-direct manufacturer page. For a quote or evaluation units, use the RFQ form or email yygl@yiyuanguanglian.cn.

Frequently asked questions

What does “compatible 1.6T OSFP224” mean in 2026?

It means the module fits the cage variant, is coded for the named host and software, uses the expected CMIS profile, and has passed a pilot on that pair. It does not mean “any 1.6T OSFP will work in any AI GPU cluster,” and it does not mean the IEEE P802.3dj draft has already been published as a final standard.

Is YYGL’s 1.6T module a drop-in for NVIDIA MMS4A00?

The live YYGL listing is in the same broad class — 1.6T-class OSFP, 2xDR4/DR8, 1310 nm, 500 m, dual MPO-12/APC, 8×200G PAM4. That is not the same as drop-in equivalence. NVIDIA’s MMS4A00 data sheet publishes different power and CMIS figures, specifies IHS, and is the part NVIDIA lists for Quantum-X800 validated configurations. Ask for a coding check and run a pilot; do not assume interchangeability.

Can I use a 1.6T OSFP224 module in ConnectX-8?

ConnectX-8 is documented as a single-cage OSFP SuperNIC, typically with 800G RHS optics, not a twin-port IHS 1.6T switch module. Using the wrong mechanical variant will not work. Confirm the exact ConnectX-8 SKU and the optic NVIDIA (or your supplier) specifies for that cage.

Does YYGL offer a 1.6T SR8 for short multimode GPU links?

No. A 1.6T SR8 is an industry form factor for short multimode links, but it is not in YYGL’s live catalog. The only 1.6T SKU listed — and the only 1.6T product this article links — is the 500 m single-mode DR4/DR8 module above. For short multimode links on 800G OSFP hosts, see the 800G OSFP SR8 listing instead.

Which IEEE standard should I write into a 1.6T purchase specification?

Reference IEEE P802.3dj as the public standard track for 200 Gb/s-per-lane 1.6T and related 800G electrical-optical interfaces, together with the OSFP MSA for the OSFP224 / OSFP1600 form factor. Require per-platform qualification until P802.3dj is published as an IEEE standard. Do not rely on earlier 100G- or 400G-class IEEE citations as a substitute for P802.3dj.

How do I request a coding check?

Send the host model, software version, module type (1.6T OSFP224 2xDR4/DR8), link distance, fiber type, and heat-sink style. YYGL states that modules can be coded for Cisco, Arista, NVIDIA Mellanox, Juniper, and Dell hosts and that compatibility depends on the host platform. Request compatibility testing or a sample before a volume order; do not treat “coded for” as a claim that the module is already fully compatible or verified on your software image.

References

  1. IEEE P802.3dj Task Force home, https://www.ieee802.org/3/dj/index.html
  2. David Law, P802.3dj 3rd SA recirculation ballot results, closed 10 October 2026, 97% approval, https://www.ieee802.org/3/email_dialog/msg01881.html
  3. IEEE 802 LMSC, conditional approval to submit P802.3dj to RevCom, 6 October 2026, https://www.ieee802.org/email/stds-802-lmsc/msg01281.html
  4. IEEE P802.3dj, unapproved minutes, 14 October 2026 (future meetings cancelled), https://ieee802.org/3/dj/public/26_1014/minutes_3dj_261014_unapproved.pdf
  5. IEEE SA, “IEEE 802.3df-2024,” https://standards.ieee.org/ieee/802.3df/11107/
  6. OSFP MSA Rev 5.0 and later, including 1.6TAUI-8 / OSFP1600 and the OSFP versus OSFP-RHS split, https://osfpmsa.org/specification.html
  7. NVIDIA, Quantum-X800 cluster documentation and MMS4A00 1600Gbps 2xDR4 twin-port OSFP (IHS, 500 m, 33.5 W max, CMIS 4.0; last updated 14 October 2026), https://networking-docs.nvidia.com/nvidia-quantum-x800-xdr-clusters and https://networking-docs.nvidia.com/9iahx00xmosfptcvr1600/
  8. NVIDIA, MMS4A20 800Gbps DR4 single-port OSFP RHS overview, https://networking-docs.nvidia.com/9iat0mosfp800sprhs/overview
  9. YYGL Optical, YY-OSFP224-DR4DR8-500M, 1.6T collection, and the existing 1.6T buying article.
Direct Manufacturer Engineering Support

Looking for High-Speed Optics for Your AI Clusters or Data Center Upgrades?

YYGL Optical engineers and manufactures high-performance 10G to 1.6T transceivers (OSFP, QSFP-DD, SFP+) pre-coded and 100% tested for Arista, Cisco, NVIDIA Mellanox, and Juniper switches. Evaluation samples and direct factory wholesale pricing are available for network engineering teams.

✓ 100% Host Switch Pre-Coded ✓ Bit Error Rate (BER) < 1E-12 Verified ✓ Direct Factory Wholesale & RFQ
返回博客